Finite element analysis to characterize how varying patellar loading influences pressure applied to cartilage : model evaluation
A finite element analysis (FEA) modeling technique has been developed to characterize how varying the orientation of the patellar tendon influences the patellofemoral pressure distribution. To evaluate the accuracy of the technique, models were created from MRI images to represent five knees that were previously tested in vitro to determine the influence of hamstrings loading on patellofemoral contact pressures. Hamstrings loading increased the lateral and posterior orientation of the patellar tendon. Each model was loaded at 40°, 60°, and 80° of flexion with quadriceps force vectors representing the experimental loading conditions. The orientation of the patellar tendon was represented for the loaded and unloaded hamstrings conditions based on experimental measures of tibiofemoral alignment. Similar to the experimental data, simulated loading of the hamstrings within the FEA models shifted the center of pressure laterally and increased the maximum lateral pressure. Significant (p < 0.05) differences were identified for the center of pressure and maximum lateral pressure from paired t-tests carried out at the individual flexion angles. The ability to replicate experimental trends indicates that the FEA models can be used for future studies focused on determining how variations in the orientation of the patellar tendon related to anatomical or loading variations or surgical procedures influence the patellofemoral pressure distribution.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2015 |
---|---|
Erschienen: |
2015 |
Enthalten in: |
Zur Gesamtaufnahme - volume:18 |
---|---|
Enthalten in: |
Computer methods in biomechanics and biomedical engineering - 18(2015), 14 vom: 12., Seite 1509-15 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Shah, Kushal S [VerfasserIn] |
---|
Links: |
---|
Themen: |
Cartilage pressure |
---|
Anmerkungen: |
Date Completed 08.01.2016 Date Revised 21.10.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1080/10255842.2014.921814 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM238668770 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM238668770 | ||
003 | DE-627 | ||
005 | 20231224114304.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2015 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1080/10255842.2014.921814 |2 doi | |
028 | 5 | 2 | |a pubmed24n0795.xml |
035 | |a (DE-627)NLM238668770 | ||
035 | |a (NLM)24874443 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Shah, Kushal S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Finite element analysis to characterize how varying patellar loading influences pressure applied to cartilage |b model evaluation |
264 | 1 | |c 2015 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 08.01.2016 | ||
500 | |a Date Revised 21.10.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a A finite element analysis (FEA) modeling technique has been developed to characterize how varying the orientation of the patellar tendon influences the patellofemoral pressure distribution. To evaluate the accuracy of the technique, models were created from MRI images to represent five knees that were previously tested in vitro to determine the influence of hamstrings loading on patellofemoral contact pressures. Hamstrings loading increased the lateral and posterior orientation of the patellar tendon. Each model was loaded at 40°, 60°, and 80° of flexion with quadriceps force vectors representing the experimental loading conditions. The orientation of the patellar tendon was represented for the loaded and unloaded hamstrings conditions based on experimental measures of tibiofemoral alignment. Similar to the experimental data, simulated loading of the hamstrings within the FEA models shifted the center of pressure laterally and increased the maximum lateral pressure. Significant (p < 0.05) differences were identified for the center of pressure and maximum lateral pressure from paired t-tests carried out at the individual flexion angles. The ability to replicate experimental trends indicates that the FEA models can be used for future studies focused on determining how variations in the orientation of the patellar tendon related to anatomical or loading variations or surgical procedures influence the patellofemoral pressure distribution | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a cartilage pressure | |
650 | 4 | |a finite element analysis | |
650 | 4 | |a patellar tendon | |
650 | 4 | |a patellofemoral joint | |
700 | 1 | |a Saranathan, Archana |e verfasserin |4 aut | |
700 | 1 | |a Koya, Bharath |e verfasserin |4 aut | |
700 | 1 | |a Elias, John J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Computer methods in biomechanics and biomedical engineering |d 1998 |g 18(2015), 14 vom: 12., Seite 1509-15 |w (DE-627)NLM097409677 |x 1476-8259 |7 nnns |
773 | 1 | 8 | |g volume:18 |g year:2015 |g number:14 |g day:12 |g pages:1509-15 |
856 | 4 | 0 | |u http://dx.doi.org/10.1080/10255842.2014.921814 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 18 |j 2015 |e 14 |b 12 |h 1509-15 |