Computer-aided segmentation and volumetry of artificial ground-glass nodules at chest CT
OBJECTIVE: The purpose of this study was to investigate a new software program for semiautomatic measurement of the volume and mass of ground-glass nodules (GGNs) in a chest phantom and to investigate the influence of CT scanner, reconstruction filter, tube voltage, and tube current.
MATERIALS AND METHODS: We used an anthropomorphic chest phantom with eight artificial GGNs with two different CT attenuations and four different volumes. CT scans were obtained with four models of CT scanner at 120 kVp and 25 mAs with a soft and a sharp reconstruction filter. On the 256-MDCT scanner, the tube current-exposure time product and tube voltage settings were varied. GGNs were measured with software that automatically segmented the nodules. Absolute percentage error (APE) was calculated for volume, mass, and density. Wilcoxon signed rank, Mann-Whitney U, and Kruskal-Wallis tests were used for analysis.
RESULTS: Volume and mass did not differ significantly from the true values. When measurements were expressed as APE, the error range was 2-36% for volume and 5-46% for mass, which was significantly different from no error. We did not find significant differences in APE between CT scanners with filters for lower tube current for volume or lower tube voltage for mass.
CONCLUSION: Computer-aided segmentation and mass and volume measurements of GGNs with the prototype software had promising results in this study.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2013 |
---|---|
Erschienen: |
2013 |
Enthalten in: |
Zur Gesamtaufnahme - volume:201 |
---|---|
Enthalten in: |
AJR. American journal of roentgenology - 201(2013), 2 vom: 21. Aug., Seite 295-300 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Scholten, Ernst Th [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 30.09.2013 Date Revised 11.03.2022 published: Print Citation Status MEDLINE |
---|
doi: |
10.2214/AJR.12.9640 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM229431976 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM229431976 | ||
003 | DE-627 | ||
005 | 20231224082136.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2013 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.2214/AJR.12.9640 |2 doi | |
028 | 5 | 2 | |a pubmed24n0764.xml |
035 | |a (DE-627)NLM229431976 | ||
035 | |a (NLM)23883209 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Scholten, Ernst Th |e verfasserin |4 aut | |
245 | 1 | 0 | |a Computer-aided segmentation and volumetry of artificial ground-glass nodules at chest CT |
264 | 1 | |c 2013 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 30.09.2013 | ||
500 | |a Date Revised 11.03.2022 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a OBJECTIVE: The purpose of this study was to investigate a new software program for semiautomatic measurement of the volume and mass of ground-glass nodules (GGNs) in a chest phantom and to investigate the influence of CT scanner, reconstruction filter, tube voltage, and tube current | ||
520 | |a MATERIALS AND METHODS: We used an anthropomorphic chest phantom with eight artificial GGNs with two different CT attenuations and four different volumes. CT scans were obtained with four models of CT scanner at 120 kVp and 25 mAs with a soft and a sharp reconstruction filter. On the 256-MDCT scanner, the tube current-exposure time product and tube voltage settings were varied. GGNs were measured with software that automatically segmented the nodules. Absolute percentage error (APE) was calculated for volume, mass, and density. Wilcoxon signed rank, Mann-Whitney U, and Kruskal-Wallis tests were used for analysis | ||
520 | |a RESULTS: Volume and mass did not differ significantly from the true values. When measurements were expressed as APE, the error range was 2-36% for volume and 5-46% for mass, which was significantly different from no error. We did not find significant differences in APE between CT scanners with filters for lower tube current for volume or lower tube voltage for mass | ||
520 | |a CONCLUSION: Computer-aided segmentation and mass and volume measurements of GGNs with the prototype software had promising results in this study | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Jacobs, Colin |e verfasserin |4 aut | |
700 | 1 | |a van Ginneken, Bram |e verfasserin |4 aut | |
700 | 1 | |a Willemink, Martin J |e verfasserin |4 aut | |
700 | 1 | |a Kuhnigk, Jan-Martin |e verfasserin |4 aut | |
700 | 1 | |a van Ooijen, Peter M A |e verfasserin |4 aut | |
700 | 1 | |a Oudkerk, Matthijs |e verfasserin |4 aut | |
700 | 1 | |a Mali, Willem P Th M |e verfasserin |4 aut | |
700 | 1 | |a de Jong, Pim A |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t AJR. American journal of roentgenology |d 1981 |g 201(2013), 2 vom: 21. Aug., Seite 295-300 |w (DE-627)NLM000037109 |x 1546-3141 |7 nnns |
773 | 1 | 8 | |g volume:201 |g year:2013 |g number:2 |g day:21 |g month:08 |g pages:295-300 |
856 | 4 | 0 | |u http://dx.doi.org/10.2214/AJR.12.9640 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 201 |j 2013 |e 2 |b 21 |c 08 |h 295-300 |