Slow pathway elimination for atrioventricular nodal reentrant tachycardia with the 8-mm tip cryoablation catheter : an 18-month follow-up study
PURPOSE: The 9-French 8-mm tip cryoablation catheter confers a high rate of acute slow pathway (SP) elimination and an acceptable short-term outcome in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The aim of this study was to investigate the long-term outcome of patients treated with this electrode in this indication.
METHODS: Eighty-two patients (female = 52) with a mean age of 54.9 ± 17.7 years underwent SP elimination for typical AVNRT with the 8-mm tip cryocatheter in our institution between November 2009 to June 2012. Clinical and procedural characteristics were prospectively collected.
RESULTS: Acute procedural success defined as AVNRT non-inducibility at the end of the procedure was obtained in 81/82 patients (98.7 %). Mean procedure duration and fluoroscopy time were 74.4 ± 28.7 min (range, 35-160 min) and 8.7 ± 5.3 min (range, 2-26 min), respectively. Mean number of energy applications was 4.0 ± 2.4 (range, 2-15). No permanent atrioventricular block was observed. Transient atrioventricular block occurred in 12 patients (14.6 %). Traumatic fast pathway conduction block occurred in one patient before cryoenergy delivery. Using an intention-to-treat analysis, 78 patients (95.1 %) remained free of AVNRT recurrence during a mean follow-up of 17.8 ± 9.3 months.
CONCLUSIONS: This study confirmed that the 8-mm tip cryocatheter is both safe and highly effective for SP conduction elimination in patients with AVNRT and demonstrated a low recurrence rate during a long-term follow-up.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2013 |
---|---|
Erschienen: |
2013 |
Enthalten in: |
Zur Gesamtaufnahme - volume:37 |
---|---|
Enthalten in: |
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing - 37(2013), 1 vom: 17. Juni, Seite 105-9 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Peyrol, Michaël [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 07.01.2014 Date Revised 21.10.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s10840-012-9768-0 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM223511838 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM223511838 | ||
003 | DE-627 | ||
005 | 20231224060827.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231224s2013 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s10840-012-9768-0 |2 doi | |
028 | 5 | 2 | |a pubmed24n0745.xml |
035 | |a (DE-627)NLM223511838 | ||
035 | |a (NLM)23247421 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Peyrol, Michaël |e verfasserin |4 aut | |
245 | 1 | 0 | |a Slow pathway elimination for atrioventricular nodal reentrant tachycardia with the 8-mm tip cryoablation catheter |b an 18-month follow-up study |
264 | 1 | |c 2013 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 07.01.2014 | ||
500 | |a Date Revised 21.10.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a PURPOSE: The 9-French 8-mm tip cryoablation catheter confers a high rate of acute slow pathway (SP) elimination and an acceptable short-term outcome in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The aim of this study was to investigate the long-term outcome of patients treated with this electrode in this indication | ||
520 | |a METHODS: Eighty-two patients (female = 52) with a mean age of 54.9 ± 17.7 years underwent SP elimination for typical AVNRT with the 8-mm tip cryocatheter in our institution between November 2009 to June 2012. Clinical and procedural characteristics were prospectively collected | ||
520 | |a RESULTS: Acute procedural success defined as AVNRT non-inducibility at the end of the procedure was obtained in 81/82 patients (98.7 %). Mean procedure duration and fluoroscopy time were 74.4 ± 28.7 min (range, 35-160 min) and 8.7 ± 5.3 min (range, 2-26 min), respectively. Mean number of energy applications was 4.0 ± 2.4 (range, 2-15). No permanent atrioventricular block was observed. Transient atrioventricular block occurred in 12 patients (14.6 %). Traumatic fast pathway conduction block occurred in one patient before cryoenergy delivery. Using an intention-to-treat analysis, 78 patients (95.1 %) remained free of AVNRT recurrence during a mean follow-up of 17.8 ± 9.3 months | ||
520 | |a CONCLUSIONS: This study confirmed that the 8-mm tip cryocatheter is both safe and highly effective for SP conduction elimination in patients with AVNRT and demonstrated a low recurrence rate during a long-term follow-up | ||
650 | 4 | |a Clinical Trial | |
650 | 4 | |a Journal Article | |
700 | 1 | |a Sbragia, Pascal |e verfasserin |4 aut | |
700 | 1 | |a Uhry, Sabrina |e verfasserin |4 aut | |
700 | 1 | |a Boccara, Gilles |e verfasserin |4 aut | |
700 | 1 | |a Dolla, Eric |e verfasserin |4 aut | |
700 | 1 | |a Quatre, Amandine |e verfasserin |4 aut | |
700 | 1 | |a Guenoun, Maxime |e verfasserin |4 aut | |
700 | 1 | |a Lévy, Samuel |e verfasserin |4 aut | |
700 | 1 | |a Paganelli, Franck |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing |d 1997 |g 37(2013), 1 vom: 17. Juni, Seite 105-9 |w (DE-627)NLM096482982 |x 1572-8595 |7 nnns |
773 | 1 | 8 | |g volume:37 |g year:2013 |g number:1 |g day:17 |g month:06 |g pages:105-9 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s10840-012-9768-0 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 37 |j 2013 |e 1 |b 17 |c 06 |h 105-9 |