Second-hand smoke exposure in hospitality venues in Barcelona : measurement of respirable particles
Copyright © 2010 SESPAS. Published by Elsevier Espana. All rights reserved..
OBJECTIVES: To quantify the concentration of respirable particles equal to or smaller than 2.5μm (PM(2.5)) as a marker of second-hand smoke (SHS) exposure in a sample of hospitality venues in Barcelona 2 years after the Spanish smoking law came into effect.
METHODS: We performed a cross-sectional descriptive study from October to December 2007. The study population consisted of 40 hospitality venues in Barcelona selected by a random route sampling, with representation of the different types of smoking regulation included in the law (smoking allowed, smoking ban and venues with smoking areas). SHS levels were quantified by measuring PM(2.5) concentrations, which were measured using a laser photometer (Side Pack AM 510 Personal Aerosol Monitor). The measurements were carried out for 5 minutes outside the venue and for 30 minutes inside the venue. In addition, observational variables related to the characteristics of the venue and signs of tobacco consumption were recorded.
RESULTS: The concentration of PM(2.5) in venues where smoking was still allowed was five times higher than that in venues where smoking was banned (182μg/m(3) and 34μg/m(3), respectively) and exceeded the concentration established by the US Environmental Protection Agency (EPA) as harmful (35μg/m(3)). However, in venues where smoking was banned, the concentration was lower than the EPA standard and there were no significant differences with the outdoor PM(2.5) concentration.
CONCLUSIONS: Two years after the introduction of the Spanish smoking law, SHS exposure in venues where smoking was allowed was q still very high, representing a significant health risk for hospitality workers.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2011 |
---|---|
Erschienen: |
2011 |
Enthalten in: |
Zur Gesamtaufnahme - volume:25 |
---|---|
Enthalten in: |
Gaceta sanitaria - 25(2011), 3 vom: 30. Mai, Seite 220-3 |
Sprache: |
Spanisch |
---|
Weiterer Titel: |
Exposición al humo ambiental de tabaco en locales de hostelería de Barcelona: medición de partículas respirables |
---|
Beteiligte Personen: |
Villarroel, Nazmy [VerfasserIn] |
---|
Links: |
---|
Themen: |
Comparative Study |
---|
Anmerkungen: |
Date Completed 03.10.2011 Date Revised 20.10.2016 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.gaceta.2010.11.009 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM206034474 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM206034474 | ||
003 | DE-627 | ||
005 | 20231223235052.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231223s2011 xx |||||o 00| ||spa c | ||
024 | 7 | |a 10.1016/j.gaceta.2010.11.009 |2 doi | |
028 | 5 | 2 | |a pubmed24n0687.xml |
035 | |a (DE-627)NLM206034474 | ||
035 | |a (NLM)21339029 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a spa | ||
100 | 1 | |a Villarroel, Nazmy |e verfasserin |4 aut | |
245 | 1 | 0 | |a Second-hand smoke exposure in hospitality venues in Barcelona |b measurement of respirable particles |
246 | 3 | 3 | |a Exposición al humo ambiental de tabaco en locales de hostelería de Barcelona: medición de partículas respirables |
264 | 1 | |c 2011 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 03.10.2011 | ||
500 | |a Date Revised 20.10.2016 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2010 SESPAS. Published by Elsevier Espana. All rights reserved. | ||
520 | |a OBJECTIVES: To quantify the concentration of respirable particles equal to or smaller than 2.5μm (PM(2.5)) as a marker of second-hand smoke (SHS) exposure in a sample of hospitality venues in Barcelona 2 years after the Spanish smoking law came into effect | ||
520 | |a METHODS: We performed a cross-sectional descriptive study from October to December 2007. The study population consisted of 40 hospitality venues in Barcelona selected by a random route sampling, with representation of the different types of smoking regulation included in the law (smoking allowed, smoking ban and venues with smoking areas). SHS levels were quantified by measuring PM(2.5) concentrations, which were measured using a laser photometer (Side Pack AM 510 Personal Aerosol Monitor). The measurements were carried out for 5 minutes outside the venue and for 30 minutes inside the venue. In addition, observational variables related to the characteristics of the venue and signs of tobacco consumption were recorded | ||
520 | |a RESULTS: The concentration of PM(2.5) in venues where smoking was still allowed was five times higher than that in venues where smoking was banned (182μg/m(3) and 34μg/m(3), respectively) and exceeded the concentration established by the US Environmental Protection Agency (EPA) as harmful (35μg/m(3)). However, in venues where smoking was banned, the concentration was lower than the EPA standard and there were no significant differences with the outdoor PM(2.5) concentration | ||
520 | |a CONCLUSIONS: Two years after the introduction of the Spanish smoking law, SHS exposure in venues where smoking was allowed was q still very high, representing a significant health risk for hospitality workers | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a English Abstract | |
650 | 4 | |a Journal Article | |
650 | 7 | |a Particulate Matter |2 NLM | |
650 | 7 | |a Tobacco Smoke Pollution |2 NLM | |
700 | 1 | |a López, María José |e verfasserin |4 aut | |
700 | 1 | |a Sánchez-Martínez, Francesca |e verfasserin |4 aut | |
700 | 1 | |a Fernández, Esteve |e verfasserin |4 aut | |
700 | 1 | |a Nebot, Manel |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Gaceta sanitaria |d 1991 |g 25(2011), 3 vom: 30. Mai, Seite 220-3 |w (DE-627)NLM012723282 |x 1578-1283 |7 nnns |
773 | 1 | 8 | |g volume:25 |g year:2011 |g number:3 |g day:30 |g month:05 |g pages:220-3 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.gaceta.2010.11.009 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 25 |j 2011 |e 3 |b 30 |c 05 |h 220-3 |