Functionalization of micro- and nano-apertures with chromate-selective solvent polymeric membrane
Copyright 2009 Elsevier B.V. All rights reserved..
A new miniaturization approach to create micro- and nanoscale ion selective electrodes (ISEs) was demonstrated and the concept tested with an environmentally relevant chromate-selective membrane consisting of 7.7:62.2:31.1 wt % Aliquat336:2-NPOE:PVC. Apertures of 100 nM and 30 microM dimensions were made using MEMS fabrication techniques and functionalized through a macroscale application of solvent polymeric membrane. Performance studies for the microscale ISE showed a response slope of -58.6+/-5.6 mV decade(-1) and limit of detection (LOD) of 2.1 x 10(-5)+/-1.1 x 10(-5) M, versus -65.2+/-4.2 mV decade(-1) and 1.8 x 10(-5)+/-6 x 10(-6) M for the nanoscale ISE. This was consistent with control studies with carefully conditioned coated wire electrodes, which demonstrated a response slope of -61.7+/-2.4 mV decade(-1) and a LOD of 3.0 x 10(-6)+/-1 x 10(-6) M. Response times for the best micro- and nanoscale ISEs were in the 10-20 s timeframe. Electrical resistance measurements were in the GOmega range for the microscale ISEs and nanoscale ISEs. Appropriate ISE geometry was confirmed through AFM measurements and calculations based on electrical properties for micro- and nanoscale apertures. These micro- and nanoscale ISEs are expected to have significant impact in the field of microscale analytical processes.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2010 |
---|---|
Erschienen: |
2010 |
Enthalten in: |
Zur Gesamtaufnahme - volume:659 |
---|---|
Enthalten in: |
Analytica chimica acta - 659(2010), 1-2 vom: 05. Feb., Seite 243-50 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Rieck, Daniel C [VerfasserIn] |
---|
Links: |
---|
Themen: |
Chromates |
---|
Anmerkungen: |
Date Completed 30.03.2010 Date Revised 26.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.aca.2009.11.030 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM194628523 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM194628523 | ||
003 | DE-627 | ||
005 | 20240326231933.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231223s2010 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.aca.2009.11.030 |2 doi | |
028 | 5 | 2 | |a pubmed24n1348.xml |
035 | |a (DE-627)NLM194628523 | ||
035 | |a (NLM)20103131 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Rieck, Daniel C |e verfasserin |4 aut | |
245 | 1 | 0 | |a Functionalization of micro- and nano-apertures with chromate-selective solvent polymeric membrane |
264 | 1 | |c 2010 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 30.03.2010 | ||
500 | |a Date Revised 26.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright 2009 Elsevier B.V. All rights reserved. | ||
520 | |a A new miniaturization approach to create micro- and nanoscale ion selective electrodes (ISEs) was demonstrated and the concept tested with an environmentally relevant chromate-selective membrane consisting of 7.7:62.2:31.1 wt % Aliquat336:2-NPOE:PVC. Apertures of 100 nM and 30 microM dimensions were made using MEMS fabrication techniques and functionalized through a macroscale application of solvent polymeric membrane. Performance studies for the microscale ISE showed a response slope of -58.6+/-5.6 mV decade(-1) and limit of detection (LOD) of 2.1 x 10(-5)+/-1.1 x 10(-5) M, versus -65.2+/-4.2 mV decade(-1) and 1.8 x 10(-5)+/-6 x 10(-6) M for the nanoscale ISE. This was consistent with control studies with carefully conditioned coated wire electrodes, which demonstrated a response slope of -61.7+/-2.4 mV decade(-1) and a LOD of 3.0 x 10(-6)+/-1 x 10(-6) M. Response times for the best micro- and nanoscale ISEs were in the 10-20 s timeframe. Electrical resistance measurements were in the GOmega range for the microscale ISEs and nanoscale ISEs. Appropriate ISE geometry was confirmed through AFM measurements and calculations based on electrical properties for micro- and nanoscale apertures. These micro- and nanoscale ISEs are expected to have significant impact in the field of microscale analytical processes | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a Research Support, U.S. Gov't, Non-P.H.S. | |
650 | 7 | |a Chromates |2 NLM | |
650 | 7 | |a Polymers |2 NLM | |
650 | 7 | |a Solvents |2 NLM | |
700 | 1 | |a Liu, Bingwen |e verfasserin |4 aut | |
700 | 1 | |a Park, Bong-Jae |e verfasserin |4 aut | |
700 | 1 | |a Moffett, David F |e verfasserin |4 aut | |
700 | 1 | |a Kidwell, David A |e verfasserin |4 aut | |
700 | 1 | |a Cheng, Gary J |e verfasserin |4 aut | |
700 | 1 | |a Van Wie, Bernard J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Analytica chimica acta |d 1966 |g 659(2010), 1-2 vom: 05. Feb., Seite 243-50 |w (DE-627)NLM000012637 |x 1873-4324 |7 nnns |
773 | 1 | 8 | |g volume:659 |g year:2010 |g number:1-2 |g day:05 |g month:02 |g pages:243-50 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.aca.2009.11.030 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 659 |j 2010 |e 1-2 |b 05 |c 02 |h 243-50 |