Digital pulse shape discrimination
Pulse-shape discrimination (PSD) has been utilised for about 40 years as a method to obtain estimates for dose in mixed neutron and photon fields. Digitizers that operate close to GHz are currently available at a reasonable cost, and they can be used to directly sample signals from photomultiplier tubes. This permits one to perform digital PSD rather than the traditional, and well-established, analogoue techniques. One issue that complicates PSD for neutrons in mixed fields is that the light output characteristics of typical scintillators available for PSD, such as BC501A, vary as a function of energy deposited in the detector. This behaviour is more easily accommodated with digital processing of signals than with analogoue signal processing. Results illustrate the effectiveness of digital PSD.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2007 |
---|---|
Erschienen: |
2007 |
Enthalten in: |
Zur Gesamtaufnahme - volume:126 |
---|---|
Enthalten in: |
Radiation protection dosimetry - 126(2007), 1-4 vom: 24., Seite 253-5 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Miller, L F [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 24.09.2008 Date Revised 19.03.2008 published: Print-Electronic Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM170948153 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM170948153 | ||
003 | DE-627 | ||
005 | 20231223124625.0 | ||
007 | tu | ||
008 | 231223s2007 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a pubmed24n0570.xml |
035 | |a (DE-627)NLM170948153 | ||
035 | |a (NLM)17575295 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Miller, L F |e verfasserin |4 aut | |
245 | 1 | 0 | |a Digital pulse shape discrimination |
264 | 1 | |c 2007 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 24.09.2008 | ||
500 | |a Date Revised 19.03.2008 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Pulse-shape discrimination (PSD) has been utilised for about 40 years as a method to obtain estimates for dose in mixed neutron and photon fields. Digitizers that operate close to GHz are currently available at a reasonable cost, and they can be used to directly sample signals from photomultiplier tubes. This permits one to perform digital PSD rather than the traditional, and well-established, analogoue techniques. One issue that complicates PSD for neutrons in mixed fields is that the light output characteristics of typical scintillators available for PSD, such as BC501A, vary as a function of energy deposited in the detector. This behaviour is more easily accommodated with digital processing of signals than with analogoue signal processing. Results illustrate the effectiveness of digital PSD | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Preston, J |e verfasserin |4 aut | |
700 | 1 | |a Pozzi, S |e verfasserin |4 aut | |
700 | 1 | |a Flaska, M |e verfasserin |4 aut | |
700 | 1 | |a Neal, J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Radiation protection dosimetry |d 1987 |g 126(2007), 1-4 vom: 24., Seite 253-5 |w (DE-627)NLM080850561 |x 1742-3406 |7 nnns |
773 | 1 | 8 | |g volume:126 |g year:2007 |g number:1-4 |g day:24 |g pages:253-5 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 126 |j 2007 |e 1-4 |b 24 |h 253-5 |