Multiplex real-time reverse transcription-PCR assay for determination of hepatitis C virus genotypes
A variety of methods have been used to determine hepatitis C virus (HCV) genotypes. Because therapeutic decisions for chronic HCV-related hepatitis are made on the basis of genotype, it is important that genotype be accurately determined by clinical laboratories. Existing methods are often subjective, inaccurate, manual, time-consuming, and contamination prone. We therefore evaluated real-time reverse transcription-PCR (RT-PCR) reagents that have recently become commercially available (Abbott HCV Genotype ASR). The assay developed by our laboratory starts with purified RNA and can be performed in 4 to 5 h. An initial evaluation of 479 samples was done with a restriction fragment length polymorphism (RFLP) method and the RT-PCR assay, and discrepant samples were sequenced. An additional 1,200 samples were then tested, and data from all assays were used to evaluate the efficiency and specificity of each genotype-specific reaction. Good correlation between results by the two methods was seen. Discrepant samples included those indeterminate by the RT-PCR assay (n = 110) and a subset that were incorrectly called 2a by the RFLP method (n = 75). The real-time RT-PCR assay performed well with genotype 1, 2, and 3 samples. Inadequate numbers of samples were available to evaluate fully genotypes 4, 5, and 6. Analysis of each primer-probe set demonstrated that weak cross-reactive amplifications were common but usually did not interfere with the genotype determination. However, in about 1% of samples, two or more genotypes amplified at roughly equivalent amounts. Further studies are necessary to determine whether these mixed-genotype samples are true mixtures or a reflection of occasional cross-reactive amplifications.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2006 |
---|---|
Erschienen: |
2006 |
Enthalten in: |
Zur Gesamtaufnahme - volume:44 |
---|---|
Enthalten in: |
Journal of clinical microbiology - 44(2006), 11 vom: 03. Nov., Seite 4149-56 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Cook, Linda [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 22.12.2006 Date Revised 13.11.2018 published: Print-Electronic Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM165482826 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM165482826 | ||
003 | DE-627 | ||
005 | 20231223104815.0 | ||
007 | tu | ||
008 | 231223s2006 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a pubmed24n0552.xml |
035 | |a (DE-627)NLM165482826 | ||
035 | |a (NLM)16988019 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Cook, Linda |e verfasserin |4 aut | |
245 | 1 | 0 | |a Multiplex real-time reverse transcription-PCR assay for determination of hepatitis C virus genotypes |
264 | 1 | |c 2006 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 22.12.2006 | ||
500 | |a Date Revised 13.11.2018 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a A variety of methods have been used to determine hepatitis C virus (HCV) genotypes. Because therapeutic decisions for chronic HCV-related hepatitis are made on the basis of genotype, it is important that genotype be accurately determined by clinical laboratories. Existing methods are often subjective, inaccurate, manual, time-consuming, and contamination prone. We therefore evaluated real-time reverse transcription-PCR (RT-PCR) reagents that have recently become commercially available (Abbott HCV Genotype ASR). The assay developed by our laboratory starts with purified RNA and can be performed in 4 to 5 h. An initial evaluation of 479 samples was done with a restriction fragment length polymorphism (RFLP) method and the RT-PCR assay, and discrepant samples were sequenced. An additional 1,200 samples were then tested, and data from all assays were used to evaluate the efficiency and specificity of each genotype-specific reaction. Good correlation between results by the two methods was seen. Discrepant samples included those indeterminate by the RT-PCR assay (n = 110) and a subset that were incorrectly called 2a by the RFLP method (n = 75). The real-time RT-PCR assay performed well with genotype 1, 2, and 3 samples. Inadequate numbers of samples were available to evaluate fully genotypes 4, 5, and 6. Analysis of each primer-probe set demonstrated that weak cross-reactive amplifications were common but usually did not interfere with the genotype determination. However, in about 1% of samples, two or more genotypes amplified at roughly equivalent amounts. Further studies are necessary to determine whether these mixed-genotype samples are true mixtures or a reflection of occasional cross-reactive amplifications | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Sullivan, KaWing |e verfasserin |4 aut | |
700 | 1 | |a Krantz, Elizabeth M |e verfasserin |4 aut | |
700 | 1 | |a Bagabag, Arthur |e verfasserin |4 aut | |
700 | 1 | |a Jerome, Keith R |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of clinical microbiology |d 1975 |g 44(2006), 11 vom: 03. Nov., Seite 4149-56 |w (DE-627)NLM000005460 |x 1098-660X |7 nnns |
773 | 1 | 8 | |g volume:44 |g year:2006 |g number:11 |g day:03 |g month:11 |g pages:4149-56 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 44 |j 2006 |e 11 |b 03 |c 11 |h 4149-56 |