Effectiveness of a hand file and three nickel-titanium rotary instruments for removing gutta-percha in curved root canals during retreatment
OBJECTIVE: This study intended to compare the effectiveness of hand files and FlexMaster, ProTaper, and RaCe rotary instruments for removing gutta-percha in curved root canals during retreatment.
STUDY DESIGN: Sixty curved mandibular premolars were randomly divided into 4 groups of 15 specimens each. The canals were enlarged and obturated using lateral condensation technique. After repreparation with the test instruments the specimens were cleared. The area of remaining obturation material was measured from 2 directions. Statistical analysis was performed using the Kruskal-Wallis test and a closed test procedure.
RESULTS: RaCe instruments revealed significantly less residual obturation material than FlexMaster files (P < .05). No significant difference was found among the hand file, ProTaper, and FlexMaster groups (P > .05). There were 5 fractured instruments in the ProTaper group and 3 in the FlexMaster group.
CONCLUSION: The RaCe system is an efficient and safe device for gutta-percha removal in curved root canals.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2006 |
---|---|
Erschienen: |
2006 |
Enthalten in: |
Zur Gesamtaufnahme - volume:101 |
---|---|
Enthalten in: |
Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics - 101(2006), 4 vom: 01. Apr., Seite 542-7 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Schirrmeister, Jörg F [VerfasserIn] |
---|
Themen: |
12035-60-8 |
---|
Anmerkungen: |
Date Completed 04.04.2006 Date Revised 30.03.2022 published: Print-Electronic Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM161353797 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM161353797 | ||
003 | DE-627 | ||
005 | 20231223092018.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231223s2006 xx |||||o 00| ||eng c | ||
028 | 5 | 2 | |a pubmed24n0538.xml |
035 | |a (DE-627)NLM161353797 | ||
035 | |a (NLM)16545721 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Schirrmeister, Jörg F |e verfasserin |4 aut | |
245 | 1 | 0 | |a Effectiveness of a hand file and three nickel-titanium rotary instruments for removing gutta-percha in curved root canals during retreatment |
264 | 1 | |c 2006 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 04.04.2006 | ||
500 | |a Date Revised 30.03.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a OBJECTIVE: This study intended to compare the effectiveness of hand files and FlexMaster, ProTaper, and RaCe rotary instruments for removing gutta-percha in curved root canals during retreatment | ||
520 | |a STUDY DESIGN: Sixty curved mandibular premolars were randomly divided into 4 groups of 15 specimens each. The canals were enlarged and obturated using lateral condensation technique. After repreparation with the test instruments the specimens were cleared. The area of remaining obturation material was measured from 2 directions. Statistical analysis was performed using the Kruskal-Wallis test and a closed test procedure | ||
520 | |a RESULTS: RaCe instruments revealed significantly less residual obturation material than FlexMaster files (P < .05). No significant difference was found among the hand file, ProTaper, and FlexMaster groups (P > .05). There were 5 fractured instruments in the ProTaper group and 3 in the FlexMaster group | ||
520 | |a CONCLUSION: The RaCe system is an efficient and safe device for gutta-percha removal in curved root canals | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a Evaluation Study | |
650 | 4 | |a Journal Article | |
650 | 7 | |a Dental Alloys |2 NLM | |
650 | 7 | |a Root Canal Filling Materials |2 NLM | |
650 | 7 | |a titanium nickelide |2 NLM | |
650 | 7 | |a 12035-60-8 |2 NLM | |
650 | 7 | |a Nickel |2 NLM | |
650 | 7 | |a 7OV03QG267 |2 NLM | |
650 | 7 | |a Gutta-Percha |2 NLM | |
650 | 7 | |a 9000-32-2 |2 NLM | |
650 | 7 | |a Titanium |2 NLM | |
650 | 7 | |a D1JT611TNE |2 NLM | |
700 | 1 | |a Wrbas, Karl-Thomas |e verfasserin |4 aut | |
700 | 1 | |a Schneider, Felix H |e verfasserin |4 aut | |
700 | 1 | |a Altenburger, Markus J |e verfasserin |4 aut | |
700 | 1 | |a Hellwig, Elmar |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics |d 1996 |g 101(2006), 4 vom: 01. Apr., Seite 542-7 |w (DE-627)NLM074658891 |x 1528-395X |7 nnns |
773 | 1 | 8 | |g volume:101 |g year:2006 |g number:4 |g day:01 |g month:04 |g pages:542-7 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 101 |j 2006 |e 4 |b 01 |c 04 |h 542-7 |