Home blood pressure self-monitoring : diagnostic performance in white-coat hypertension
OBJECTIVE: To determine the diagnostic performance of home blood pressure self-monitoring in white-coat hypertension using a 3-day reading program.
MATERIAL AND METHODS: One hundred and ninety nontreated patients recently diagnosed with mild-moderate hypertension, selected consecutively at four primary healthcare centers in the city of Barcelona, were included. Each patient underwent morning and night home blood pressure self-monitoring with readings in triplicate for three consecutive days, followed by 24-h ambulatory blood pressure monitoring. The normality cut-off point value for home blood pressure self-monitoring and daytime ambulatory blood pressure monitoring was 135/85 mmHg.
RESULTS: Sixty-three patients were diagnosed with white-coat hypertension with home blood pressure self-monitoring (34.8%; 95% confidence interval: 27.9-42.2) and 74 with ambulatory blood pressure monitoring (41.6%; 95% confidence interval: 33.7-48.4). No statistically significant differences were observed between home blood pressure self-monitoring values and those of diurnal ambulatory blood pressure monitoring [137.4 (14.3)/82.1 (8.3) mmHg vs. 134.8 (11.3)/81.3 (9.5) mmHg]. Home blood pressure self-monitoring diagnostic performance parameters were sensitivity 50.0% (95% confidence interval: 38.3-61.7), specificity 75.7% (95% confidence interval: 66.3-83.2), positive and negative predictive values 58.7% (95% confidence interval: 45.6-70.8) and 68.6% (95% confidence interval: 59.4-76.7), respectively, and positive and negative probability coefficients 2.05 and 0.66, respectively. Analysis of different normality cut-off points using a receiver operating characteristic curve failed to produce significant improvement in the diagnostic performance of home blood pressure self-monitoring.
CONCLUSIONS: The diagnostic accuracy of a 3-day home blood pressure self-monitoring reading program in white-coat hypertension was poor. Ambulatory blood pressure monitoring continues to be the test of choice for this indication.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2006 |
---|---|
Erschienen: |
2006 |
Enthalten in: |
Zur Gesamtaufnahme - volume:11 |
---|---|
Enthalten in: |
Blood pressure monitoring - 11(2006), 2 vom: 13. Apr., Seite 47-52 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Bayó, Joan [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 05.06.2006 Date Revised 15.11.2006 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM16124730X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM16124730X | ||
003 | DE-627 | ||
005 | 20231223091807.0 | ||
007 | tu | ||
008 | 231223s2006 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a pubmed24n0538.xml |
035 | |a (DE-627)NLM16124730X | ||
035 | |a (NLM)16534404 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Bayó, Joan |e verfasserin |4 aut | |
245 | 1 | 0 | |a Home blood pressure self-monitoring |b diagnostic performance in white-coat hypertension |
264 | 1 | |c 2006 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 05.06.2006 | ||
500 | |a Date Revised 15.11.2006 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a OBJECTIVE: To determine the diagnostic performance of home blood pressure self-monitoring in white-coat hypertension using a 3-day reading program | ||
520 | |a MATERIAL AND METHODS: One hundred and ninety nontreated patients recently diagnosed with mild-moderate hypertension, selected consecutively at four primary healthcare centers in the city of Barcelona, were included. Each patient underwent morning and night home blood pressure self-monitoring with readings in triplicate for three consecutive days, followed by 24-h ambulatory blood pressure monitoring. The normality cut-off point value for home blood pressure self-monitoring and daytime ambulatory blood pressure monitoring was 135/85 mmHg | ||
520 | |a RESULTS: Sixty-three patients were diagnosed with white-coat hypertension with home blood pressure self-monitoring (34.8%; 95% confidence interval: 27.9-42.2) and 74 with ambulatory blood pressure monitoring (41.6%; 95% confidence interval: 33.7-48.4). No statistically significant differences were observed between home blood pressure self-monitoring values and those of diurnal ambulatory blood pressure monitoring [137.4 (14.3)/82.1 (8.3) mmHg vs. 134.8 (11.3)/81.3 (9.5) mmHg]. Home blood pressure self-monitoring diagnostic performance parameters were sensitivity 50.0% (95% confidence interval: 38.3-61.7), specificity 75.7% (95% confidence interval: 66.3-83.2), positive and negative predictive values 58.7% (95% confidence interval: 45.6-70.8) and 68.6% (95% confidence interval: 59.4-76.7), respectively, and positive and negative probability coefficients 2.05 and 0.66, respectively. Analysis of different normality cut-off points using a receiver operating characteristic curve failed to produce significant improvement in the diagnostic performance of home blood pressure self-monitoring | ||
520 | |a CONCLUSIONS: The diagnostic accuracy of a 3-day home blood pressure self-monitoring reading program in white-coat hypertension was poor. Ambulatory blood pressure monitoring continues to be the test of choice for this indication | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Cos, Francesc Xavier |e verfasserin |4 aut | |
700 | 1 | |a Roca, Carme |e verfasserin |4 aut | |
700 | 1 | |a Dalfó, Antoni |e verfasserin |4 aut | |
700 | 1 | |a Martín-Baranera, Maria Montserrat |e verfasserin |4 aut | |
700 | 1 | |a Albert, Botey |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Blood pressure monitoring |d 1996 |g 11(2006), 2 vom: 13. Apr., Seite 47-52 |w (DE-627)NLM095469427 |x 1473-5725 |7 nnns |
773 | 1 | 8 | |g volume:11 |g year:2006 |g number:2 |g day:13 |g month:04 |g pages:47-52 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 11 |j 2006 |e 2 |b 13 |c 04 |h 47-52 |