The value of myocardial perfusion scintigraphy as a "gatekeeper" for coronary angiography and revascularisation in patients with stable angina pectoris--a secondary publication
In 507 out of a series of 972 patients referred consecutively to coronary angiography (CA) for stable angina pectoris, preceding "blinded" myocardial perfusion scintigraphy (MPS) demonstrated normal perfusion in 51%, reversible defects in 40%, and fixed defects in 9% of patients. CA showed insignificant findings in 49% and in 41% of the entire series. Of 168 revascularised patients, no more than 74% had reversible perfusion defects with MPS. On this basis it could be estimated that almost half of catheterizations and nearly one fifth of revascularisations were "superfluous".
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2006 |
---|---|
Erschienen: |
2006 |
Enthalten in: |
Zur Gesamtaufnahme - volume:168 |
---|---|
Enthalten in: |
Ugeskrift for laeger - 168(2006), 8 vom: 20. Feb., Seite 799-802 |
Sprache: |
Dänisch |
---|
Weiterer Titel: |
Vaerdien af myokardieskintigrafi som gatekeeper for koronararteriografi og revaskularisering hos patienter med stabil angina pectoris--sekundaerpublikation |
---|
Beteiligte Personen: |
Høilund-Carlsen, Poul Flemming [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 02.03.2006 Date Revised 24.11.2016 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM160921260 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM160921260 | ||
003 | DE-627 | ||
005 | 20231223091110.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231223s2006 xx |||||o 00| ||dan c | ||
028 | 5 | 2 | |a pubmed24n0537.xml |
035 | |a (DE-627)NLM160921260 | ||
035 | |a (NLM)16499846 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a dan | ||
100 | 1 | |a Høilund-Carlsen, Poul Flemming |e verfasserin |4 aut | |
245 | 1 | 4 | |a The value of myocardial perfusion scintigraphy as a "gatekeeper" for coronary angiography and revascularisation in patients with stable angina pectoris--a secondary publication |
246 | 3 | 3 | |a Vaerdien af myokardieskintigrafi som gatekeeper for koronararteriografi og revaskularisering hos patienter med stabil angina pectoris--sekundaerpublikation |
264 | 1 | |c 2006 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 02.03.2006 | ||
500 | |a Date Revised 24.11.2016 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a In 507 out of a series of 972 patients referred consecutively to coronary angiography (CA) for stable angina pectoris, preceding "blinded" myocardial perfusion scintigraphy (MPS) demonstrated normal perfusion in 51%, reversible defects in 40%, and fixed defects in 9% of patients. CA showed insignificant findings in 49% and in 41% of the entire series. Of 168 revascularised patients, no more than 74% had reversible perfusion defects with MPS. On this basis it could be estimated that almost half of catheterizations and nearly one fifth of revascularisations were "superfluous" | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Johansen, Allan H D |e verfasserin |4 aut | |
700 | 1 | |a Christensen, Henrik Wulff |e verfasserin |4 aut | |
700 | 1 | |a Vach, Werner |e verfasserin |4 aut | |
700 | 1 | |a Møldrup, Mette |e verfasserin |4 aut | |
700 | 1 | |a Bartram, Peter Henning |e verfasserin |4 aut | |
700 | 1 | |a Veje, Annegrete |e verfasserin |4 aut | |
700 | 1 | |a Haghfelt, Torben |e verfasserin |4 aut | |
700 | 0 | |a Myocardial Ischemia Logistics Evaluation Study (MILES) Group |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Ugeskrift for laeger |d 1945 |g 168(2006), 8 vom: 20. Feb., Seite 799-802 |w (DE-627)NLM000011185 |x 1603-6824 |7 nnns |
773 | 1 | 8 | |g volume:168 |g year:2006 |g number:8 |g day:20 |g month:02 |g pages:799-802 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 168 |j 2006 |e 8 |b 20 |c 02 |h 799-802 |