Detection of Escherichia coli in wastewater based on enzyme immunoassay
This research described the fast detection method based on ELISA for the E. coli in drain of wastewater treatment plants. The optimized conditions, such as reaction format (sandwich or direct), the concentration of HRP-E. coli conjugate, anti-HPR antibody and pretreatment of E. coli, were studied. Those results showed that the linear range of detection for E. coli was 10 CFU/ mL - 6 x 10(4) CFU/mL. This method shows the potential ability for the technics control of wastewater treatment plants. Comparing with conventional methods, it is a convenient and sensitive detection method with low cost.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2005 |
---|---|
Erschienen: |
2005 |
Enthalten in: |
Zur Gesamtaufnahme - volume:26 |
---|---|
Enthalten in: |
Huan jing ke xue= Huanjing kexue - 26(2005), 5 vom: 23. Sept., Seite 128-31 |
Sprache: |
Chinesisch |
---|
Beteiligte Personen: |
Xi, Hai-Yan [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 22.12.2006 Date Revised 09.12.2020 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM159674743 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM159674743 | ||
003 | DE-627 | ||
005 | 20231223084606.0 | ||
007 | tu | ||
008 | 231223s2005 xx ||||| 00| ||chi c | ||
028 | 5 | 2 | |a pubmed24n0532.xml |
035 | |a (DE-627)NLM159674743 | ||
035 | |a (NLM)16366484 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a chi | ||
100 | 1 | |a Xi, Hai-Yan |e verfasserin |4 aut | |
245 | 1 | 0 | |a Detection of Escherichia coli in wastewater based on enzyme immunoassay |
264 | 1 | |c 2005 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 22.12.2006 | ||
500 | |a Date Revised 09.12.2020 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a This research described the fast detection method based on ELISA for the E. coli in drain of wastewater treatment plants. The optimized conditions, such as reaction format (sandwich or direct), the concentration of HRP-E. coli conjugate, anti-HPR antibody and pretreatment of E. coli, were studied. Those results showed that the linear range of detection for E. coli was 10 CFU/ mL - 6 x 10(4) CFU/mL. This method shows the potential ability for the technics control of wastewater treatment plants. Comparing with conventional methods, it is a convenient and sensitive detection method with low cost | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Cai, Qiang |e verfasserin |4 aut | |
700 | 1 | |a He, Miao |e verfasserin |4 aut | |
700 | 1 | |a Shi, Han-Chang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Huan jing ke xue= Huanjing kexue |d 1993 |g 26(2005), 5 vom: 23. Sept., Seite 128-31 |w (DE-627)NLM083800301 |x 0250-3301 |7 nnns |
773 | 1 | 8 | |g volume:26 |g year:2005 |g number:5 |g day:23 |g month:09 |g pages:128-31 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 26 |j 2005 |e 5 |b 23 |c 09 |h 128-31 |