Stability of hip hemiarthroplasties
It has been stated in the literature that a bipolar hemiarthroplasty has a lower risk of dislocation compared to a unipolar hemiarthroplasty. As this statement has not been substantiated we undertook a systematic review of the literature of published articles from the last 40 years. In addition we used our own database of hip fractures. One hundred and thirty-three published articles were included in the review to give a total of 23,107 cases. The overall dislocation rate for all types of hemiarthroplasty was 791/23,107 (3.4%). An increased risk of dislocation was associated with a posterior surgical approach and the use of a cemented prosthesis. After adjustment for surgical approach and the use of cement there was no difference in risk of dislocation between unipolar and bipolar hemiarthroplasties. There was an increased risk of open reduction for a bipolar hemiarthroplasty.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2004 |
---|---|
Erschienen: |
2004 |
Enthalten in: |
Zur Gesamtaufnahme - volume:28 |
---|---|
Enthalten in: |
International orthopaedics - 28(2004), 5 vom: 04. Okt., Seite 274-7 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Varley, James [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 05.04.2005 Date Revised 08.04.2022 published: Print-Electronic Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM149964722 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM149964722 | ||
003 | DE-627 | ||
005 | 20231223052837.0 | ||
007 | tu | ||
008 | 231223s2004 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a pubmed24n0500.xml |
035 | |a (DE-627)NLM149964722 | ||
035 | |a (NLM)15316673 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Varley, James |e verfasserin |4 aut | |
245 | 1 | 0 | |a Stability of hip hemiarthroplasties |
264 | 1 | |c 2004 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 05.04.2005 | ||
500 | |a Date Revised 08.04.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a It has been stated in the literature that a bipolar hemiarthroplasty has a lower risk of dislocation compared to a unipolar hemiarthroplasty. As this statement has not been substantiated we undertook a systematic review of the literature of published articles from the last 40 years. In addition we used our own database of hip fractures. One hundred and thirty-three published articles were included in the review to give a total of 23,107 cases. The overall dislocation rate for all types of hemiarthroplasty was 791/23,107 (3.4%). An increased risk of dislocation was associated with a posterior surgical approach and the use of a cemented prosthesis. After adjustment for surgical approach and the use of cement there was no difference in risk of dislocation between unipolar and bipolar hemiarthroplasties. There was an increased risk of open reduction for a bipolar hemiarthroplasty | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
650 | 4 | |a Systematic Review | |
700 | 1 | |a Parker, Martyn J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t International orthopaedics |d 1979 |g 28(2004), 5 vom: 04. Okt., Seite 274-7 |w (DE-627)NLM000959146 |x 1432-5195 |7 nnns |
773 | 1 | 8 | |g volume:28 |g year:2004 |g number:5 |g day:04 |g month:10 |g pages:274-7 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 28 |j 2004 |e 5 |b 04 |c 10 |h 274-7 |