A comparison of Legionella pneumophila occurrence in hot water tanks and instantaneous devices in domestic, nosocomial, and community environments
The aim of this study was to compare the occurrence of L. pneumophila in hot water samples from hot water tanks and instantaneous devices. Tanks and devices were all operated by heat exchangers employed in the town's district heating system. Thirty-six out of 171 (21%) hot water samples tested positive for L. pneumophila isolation, with 14.6% belonging to serogroup 1 and 6.4% to serogroups 2-14. The proportion of L. pneumophila detected in hot water reservoirs (30%) was higher than that observed in hot water instantaneous devices (6.2%). Differences in L. pneumophila isolation reflected different temperatures registered at the faucet: </=50 degrees C for hot water from reservoir devices, and >60 degrees C for hot water from instantaneous devices. These data emphasize the need to control temperature in hot water distribution devices, thus inhibiting the formation of biofilm and L. pneumophila colonization.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2000 |
---|---|
Erschienen: |
2000 |
Enthalten in: |
Zur Gesamtaufnahme - volume:41 |
---|---|
Enthalten in: |
Current microbiology - 41(2000), 5 vom: 01. Nov., Seite 374-6 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Martinelli, F [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 01.02.2001 Date Revised 25.10.2019 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM109345088 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM109345088 | ||
003 | DE-627 | ||
005 | 20231222151135.0 | ||
007 | tu | ||
008 | 231222s2000 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a pubmed24n0365.xml |
035 | |a (DE-627)NLM109345088 | ||
035 | |a (NLM)11014877 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Martinelli, F |e verfasserin |4 aut | |
245 | 1 | 2 | |a A comparison of Legionella pneumophila occurrence in hot water tanks and instantaneous devices in domestic, nosocomial, and community environments |
264 | 1 | |c 2000 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 01.02.2001 | ||
500 | |a Date Revised 25.10.2019 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The aim of this study was to compare the occurrence of L. pneumophila in hot water samples from hot water tanks and instantaneous devices. Tanks and devices were all operated by heat exchangers employed in the town's district heating system. Thirty-six out of 171 (21%) hot water samples tested positive for L. pneumophila isolation, with 14.6% belonging to serogroup 1 and 6.4% to serogroups 2-14. The proportion of L. pneumophila detected in hot water reservoirs (30%) was higher than that observed in hot water instantaneous devices (6.2%). Differences in L. pneumophila isolation reflected different temperatures registered at the faucet: </=50 degrees C for hot water from reservoir devices, and >60 degrees C for hot water from instantaneous devices. These data emphasize the need to control temperature in hot water distribution devices, thus inhibiting the formation of biofilm and L. pneumophila colonization | ||
650 | 4 | |a Comparative Study | |
650 | 4 | |a Journal Article | |
700 | 1 | |a Caruso, A |e verfasserin |4 aut | |
700 | 1 | |a Moschini, L |e verfasserin |4 aut | |
700 | 1 | |a Turano, A |e verfasserin |4 aut | |
700 | 1 | |a Scarcella, C |e verfasserin |4 aut | |
700 | 1 | |a Speziani, F |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Current microbiology |d 1978 |g 41(2000), 5 vom: 01. Nov., Seite 374-6 |w (DE-627)NLM01260318X |x 1432-0991 |7 nnns |
773 | 1 | 8 | |g volume:41 |g year:2000 |g number:5 |g day:01 |g month:11 |g pages:374-6 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 41 |j 2000 |e 5 |b 01 |c 11 |h 374-6 |