Alterations in fibrin detected in coronary sinus blood after heparin and coronary angiography with a nonionic contrast agent (iohexol)

Although heparin and some radiographic contrast agents inhibit coagulation, thrombi can still form in their presence. The chemical environment in which a thrombus forms affects fibrin structure that may alter the ability of the thrombus to be lysed. Therefore, we assessed changes in fibrin structure in 13 patients referred for coronary angiography. Blood was obtained from the femoral vein, femoral artery, ascending aorta, left main coronary artery (LMCA), and coronary sinus (CS) before, during, and after coronary angiography was performed with iohexol. The number of fibrin monomers per fiber cross section was determined by turbidity measurements of fibrin gels formed from plasma samples. At baseline there was no difference in the number of fibrin monomers per fiber cross section in plasma gels generated from the different sampling sites. After iohexol administration, there was a significant decrease in the number of fibrin monomers per fiber cross section at the sampling sites ranging from - 13% to -25% compared with the respective baseline values with the largest change in the LMCA CS (51+/-16 to 38+/-15, p <0.025). Transcardiac (LM - CS value) changes in the number of fibrin monomers per fiber cross section were dependent on the timing of the sample collection in the CS. In 7 patients, the CS sample was collected approximately 2 minutes after injection of contrast material and there was no transcardiac difference. When the CS sample was obtained during contrast injection (n=6) a large transcardiac change occurred (44+/-10 to 32+/-14, p=0.01). These data show transient changes in fibrin structure during coronary angiography with iohexol. The thinner fibers formed in the presence of iohexol were more resistant to fibrinolysis.

Medienart:

Artikel

Erscheinungsjahr:

1998

Erschienen:

1998

Enthalten in:

Zur Gesamtaufnahme - volume:82

Enthalten in:

The American journal of cardiology - 82(1998), 3 vom: 01. Aug., Seite 295-8

Sprache:

Englisch

Beteiligte Personen:

Melton, L G [VerfasserIn]
Dehmer, G J [VerfasserIn]
Gabriel, D A [VerfasserIn]

Themen:

4419T9MX03
9005-49-6
Anticoagulants
Comparative Study
Contrast Media
Fibrin Fibrinogen Degradation Products
Fibrinmonomer
Heparin
Iohexol
Journal Article

Anmerkungen:

Date Completed 01.09.1998

Date Revised 22.06.2019

published: Print

Citation Status MEDLINE

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM096479892