The Guepar total elbow arthroplasty
The Guepar total elbow replacement is a low friction, minimally constrained gliding prosthesis. The humeral and ulnar components are of metal with intramedullary stems, which are cemented. There is a sigmoid shaped, high density polyethylene interposition bearing. The authors have used the prosthesis in 33 patients with rheumatoid arthritis, 4 with post-traumatic problems, one with chondrocalcinosis and another with degenerative changes of uncertain aetiology. In the patients with rheumatoid arthritis, one sustained a posterior dislocation and two suffered deep infection. In the remaining 30, the overall results were good at an average review of 32 months. The mean range of movement had increased by 31 degrees and pain was absent in 28 elbows. In the management of rheumatoid arthritis total elbow arthroplasty must be part of an overall plan of treatment. Severe involvement of the wrist and shoulder must be dealt with before elbow replacement is considered.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
1994 |
---|---|
Erschienen: |
1994 |
Enthalten in: |
Zur Gesamtaufnahme - volume:18 |
---|---|
Enthalten in: |
International orthopaedics - 18(1994), 2 vom: 13. Apr., Seite 80-9 |
Sprache: |
Französisch |
---|
Weiterer Titel: |
La prothèse totale du coude GUEPAR. Groupe pour l'utilisation et l'étude des prothèses articulaires |
---|
Beteiligte Personen: |
Alnot, J Y [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 19.08.1994 Date Revised 15.05.2019 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM080151671 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM080151671 | ||
003 | DE-627 | ||
005 | 20231222043757.0 | ||
007 | tu | ||
008 | 231222s1994 xx ||||| 00| ||fre c | ||
028 | 5 | 2 | |a pubmed24n0267.xml |
035 | |a (DE-627)NLM080151671 | ||
035 | |a (NLM)8039963 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a fre | ||
100 | 1 | |a Alnot, J Y |e verfasserin |4 aut | |
245 | 1 | 4 | |a The Guepar total elbow arthroplasty |
246 | 3 | 3 | |a La prothèse totale du coude GUEPAR. Groupe pour l'utilisation et l'étude des prothèses articulaires |
264 | 1 | |c 1994 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 19.08.1994 | ||
500 | |a Date Revised 15.05.2019 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The Guepar total elbow replacement is a low friction, minimally constrained gliding prosthesis. The humeral and ulnar components are of metal with intramedullary stems, which are cemented. There is a sigmoid shaped, high density polyethylene interposition bearing. The authors have used the prosthesis in 33 patients with rheumatoid arthritis, 4 with post-traumatic problems, one with chondrocalcinosis and another with degenerative changes of uncertain aetiology. In the patients with rheumatoid arthritis, one sustained a posterior dislocation and two suffered deep infection. In the remaining 30, the overall results were good at an average review of 32 months. The mean range of movement had increased by 31 degrees and pain was absent in 28 elbows. In the management of rheumatoid arthritis total elbow arthroplasty must be part of an overall plan of treatment. Severe involvement of the wrist and shoulder must be dealt with before elbow replacement is considered | ||
650 | 4 | |a English Abstract | |
650 | 4 | |a Journal Article | |
700 | 1 | |a Augereau, B |e verfasserin |4 aut | |
700 | 1 | |a Bellemère, P |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t International orthopaedics |d 1979 |g 18(1994), 2 vom: 13. Apr., Seite 80-9 |w (DE-627)NLM000959146 |x 1432-5195 |7 nnns |
773 | 1 | 8 | |g volume:18 |g year:1994 |g number:2 |g day:13 |g month:04 |g pages:80-9 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 18 |j 1994 |e 2 |b 13 |c 04 |h 80-9 |