Analysis of the Genotoxic Impurity S-(+)-Epichlorohydrin Contained in (S)-Oxiracetam using Gas Chromatography / Jinbiao Li, Dandan Li, Wenjing Lu, Jinhui Wu, Hong Dong
Background: (S)-oxiracetam has shown better efficacy than racemic oxiracetam in the trial. However, there is no report on the method used to detect the genotoxic impurity of S-(+)- epichlorohydrin(S-(+)-ECH) that may be contained in (S)-oxiracetam. Objective: Here, we have proposed and verified a detailed analysis method for the (S-(+)-ECH) impurity in (S)-oxiracetam using a gas chromatography(GC) system. Methods: The chromatography system includes a Supelco DB-624 capillary column. The initial column temperature was 50°C, kept for 4 minutes, and then increased to 220°C at a rate of 10°C/min for 4 minutes. Nitrogen was used as the carrier gas. The constant flow rate was 3.8 mL/min, the split ratio was 10:1, the injection port temperature was maintained at 200°C, and a hydrogen flame ionization detector was used. S-(+)-ECH was analyzed in detail by this analysis method, and three different batches of samples were measured. The GC system was used for verification. Results: The method verification results included the system suitability, specificity, sensitivity, accuracy, precision, and the good correlation coefficient between peak responses and concentrations were over 0.990. Conclusion: The method proposed in this study is the most detailed GC method currently used for the analysis of S-(+)-ECH impurities in (S)-oxiracetam. The proposed method has the advantages of fast, convenience, low cost, etc. It provides a reference method for quality control of genotoxic impurity of (S)-oxiracetam.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:18 |
---|---|
Enthalten in: |
Current pharmaceutical analysis - 18(2022), 6, Seite 8 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Li, Jinbiao [VerfasserIn] |
---|
Links: |
FID Access [lizenzpflichtig] |
---|
Umfang: |
1 Online-Ressource (8 p) |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
KFL011170573 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | KFL011170573 | ||
003 | DE-627 | ||
005 | 20231128145746.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230613s2022 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)KFL011170573 | ||
035 | |a (KFL)prod_DARH_.817D5E127DC97CBAE5277C48CB41A8EE9E5FE416 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
084 | |a PHARM |q DE-84 |2 fid | ||
100 | 1 | |a Li, Jinbiao |e verfasserin |4 aut | |
245 | 1 | 0 | |a Analysis of the Genotoxic Impurity S-(+)-Epichlorohydrin Contained in (S)-Oxiracetam using Gas Chromatography |c Jinbiao Li, Dandan Li, Wenjing Lu, Jinhui Wu, Hong Dong |
264 | 1 | |c 2022 | |
300 | |a 1 Online-Ressource (8 p) | ||
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Background: (S)-oxiracetam has shown better efficacy than racemic oxiracetam in the trial. However, there is no report on the method used to detect the genotoxic impurity of S-(+)- epichlorohydrin(S-(+)-ECH) that may be contained in (S)-oxiracetam. Objective: Here, we have proposed and verified a detailed analysis method for the (S-(+)-ECH) impurity in (S)-oxiracetam using a gas chromatography(GC) system. Methods: The chromatography system includes a Supelco DB-624 capillary column. The initial column temperature was 50°C, kept for 4 minutes, and then increased to 220°C at a rate of 10°C/min for 4 minutes. Nitrogen was used as the carrier gas. The constant flow rate was 3.8 mL/min, the split ratio was 10:1, the injection port temperature was maintained at 200°C, and a hydrogen flame ionization detector was used. S-(+)-ECH was analyzed in detail by this analysis method, and three different batches of samples were measured. The GC system was used for verification. Results: The method verification results included the system suitability, specificity, sensitivity, accuracy, precision, and the good correlation coefficient between peak responses and concentrations were over 0.990. Conclusion: The method proposed in this study is the most detailed GC method currently used for the analysis of S-(+)-ECH impurities in (S)-oxiracetam. The proposed method has the advantages of fast, convenience, low cost, etc. It provides a reference method for quality control of genotoxic impurity of (S)-oxiracetam | ||
700 | 1 | |a Li, Dandan |e verfasserin |4 aut | |
700 | 1 | |a Lu, Wenjing |e verfasserin |4 aut | |
700 | 1 | |a Wu, Jinhui |e verfasserin |4 aut | |
700 | 1 | |a Dong, Hong |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Current pharmaceutical analysis |d Sharjah, U.A.E. : Bentham Science Publ., 2005 |g 18(2022), 6, Seite 8 |h Online-Ressource |w (DE-627)KFL000006440 |w (DE-600)2216923-4 |w (DE-576)306832917 |x 1875-676X |7 nnns |
773 | 1 | 8 | |g volume:18 |g year:2022 |g number:6 |g pages:8 |
856 | 4 | 0 | |u http://pharmazie.proxy.fid-lizenzen.de/fid/bentham-ejournals-pharmazie/www.eurekaselect.com/openurl/content.php?genre=article&issn=1573-4129&volume=18&issue=6&spage=642 |m X:KFL |x Verlag |y FID Access |z lizenzpflichtig |
912 | |a ZDB-1-BEJ | ||
912 | |a GBV_KFL | ||
912 | |a FID-PHARM | ||
935 | |i IMPORT_0628_prod_DARH_03 | ||
951 | |a AR | ||
952 | |d 18 |j 2022 |e 6 |h 8 |