Simultaneous measurement of mouse and human albumin in chimeric mice with humanized livers / France Landry, Hong Shen, Yueping Zhang, Asako Uchiyama, Yoshinari Miyata, Yoshio Morikawa, Beth Joshi, Petia Shipkova
Background:The degree of human hepatocyte replacement in chimeric mice with humanized liver has previously been shown to correlate with human plasma albumin measurements. However, there are no reports that directly compare the remaining endogenous mouse albumin with the newly expressed human albumin following engraftment. To better understand the disposition of serum albumin in PXB-mice, we developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) method to simultaneously quantitate both human and mouse albumin from plasma.Results:A robust correlation was observed between the serum human albumin levels measured by LC-MS/MS and the estimated replacement index of PXB-mice.Conclusion:All data were shown to be specific and suitable to accurately quantify both human and mouse albumin from plasma of chimeric mice with humanized livers. Background: Results: Conclusion.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
Erscheinungsort nicht ermittelbar: 2022 |
Enthalten in: |
---|
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Landry, France [VerfasserIn] |
---|
Links: |
FID Access [lizenzpflichtig] |
---|
Themen: |
Albumin |
---|
Umfang: |
1 Online-Ressource (12 p) |
---|
doi: |
10.4155/bio-2021-0250 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
KFL011093447 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | KFL011093447 | ||
003 | DE-627 | ||
005 | 20230713210632.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230609s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.4155/bio-2021-0250 |2 doi | |
035 | |a (DE-627)KFL011093447 | ||
035 | |a (KFL)prod_FICIBQ_10.4155/bio-2021-0250 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
084 | |a PHARM |q DE-84 |2 fid | ||
100 | 1 | |a Landry, France |e verfasserin |4 aut | |
245 | 1 | 0 | |a Simultaneous measurement of mouse and human albumin in chimeric mice with humanized livers |c France Landry, Hong Shen, Yueping Zhang, Asako Uchiyama, Yoshinari Miyata, Yoshio Morikawa, Beth Joshi, Petia Shipkova |
264 | 1 | |a [Erscheinungsort nicht ermittelbar] |c 2022 | |
300 | |a 1 Online-Ressource (12 p) | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Background:The degree of human hepatocyte replacement in chimeric mice with humanized liver has previously been shown to correlate with human plasma albumin measurements. However, there are no reports that directly compare the remaining endogenous mouse albumin with the newly expressed human albumin following engraftment. To better understand the disposition of serum albumin in PXB-mice, we developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) method to simultaneously quantitate both human and mouse albumin from plasma.Results:A robust correlation was observed between the serum human albumin levels measured by LC-MS/MS and the estimated replacement index of PXB-mice.Conclusion:All data were shown to be specific and suitable to accurately quantify both human and mouse albumin from plasma of chimeric mice with humanized livers. Background: Results: Conclusion | ||
653 | |a albumin | ||
653 | |a chimera | ||
653 | |a hepatocytes | ||
653 | |a humanized | ||
653 | |a LC-MS/MS | ||
653 | |a liver | ||
653 | |a mice | ||
653 | |a plasma | ||
653 | |a PXB-mouse | ||
653 | |a quantification | ||
700 | 1 | |a Shen, Hong |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Yueping |e verfasserin |4 aut | |
700 | 1 | |a Uchiyama, Asako |e verfasserin |4 aut | |
700 | 1 | |a Miyata, Yoshinari |e verfasserin |4 aut | |
700 | 1 | |a Morikawa, Yoshio |e verfasserin |4 aut | |
700 | 1 | |a Joshi, Beth |e verfasserin |4 aut | |
700 | 1 | |a Shipkova, Petia |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Bioanalysis |d London : Future Science, 2009 |h Online-Ressource |w (DE-627)KFL000038172 |w (DE-600)2571813-7 |w (DE-576)398101434 |x 1757-6199 |7 nnns |
856 | 4 | 0 | |u http://pharmazie.proxy.fid-lizenzen.de/fid/future-medicine-ejournals-pharmazie/doi.org/10.4155/bio-2021-0250 |m X:KFL |x Resolving-System |y FID Access |z lizenzpflichtig |
912 | |a GBV_KFL | ||
912 | |a FID-PHARM | ||
935 | |i IMPORT_0628_prod_FICIBQ_03 | ||
951 | |a AR |