Sensitivity and specificity of the method of acoustic diagnosis of pneumonia using the acoustic monitoring device Trembita-Corona
Background. Diagnosis of pneumonia is difficult and requires a comprehensive examination. Respiratory acoustics is currently a promising diagnostic method. The purpose was to evaluate the possibility of pneumonia detection by the average signal power, frequency and amplitude of the acoustic signal using the Trembita-Corona acoustic monitoring device. Materials and methods. Onу hundred and ninety-three children aged from 1 month to 18 years were examined. The children were divided into two groups: group I — 98 patients with community-acquired pneumonia, group II — 95 healthy children. All children were examined using the Trembita-Corona acoustic monitoring device. Results. The sensitivity of the method for detecting pneumonia using the acoustic monitoring device Trembita-Corona according to the average signal power in the 4th, 5th and 6th octaves is from 90.8 to 99 %, and the specificity is from 87.4 to 100 %. The sensitivity of the method for detecting pneumonia using the acoustic monitoring device Trembita-Corona according to the frequency of the acoustic signal in the 3rd and 5th octaves is more than 60 %, and the specificity is more than 63 % in the 3rd octave and 100 % in the 5th octave, respectively. The sensitivity of the method for detecting pneumonia using the acoustic monitoring device Trembita-Corona according to the amplitude of the acoustic signal in the 4th, 5th and 6th octaves is 88.9, 99.9 and 86.9 %, respectively, and the specificity is 100 % in the 4th and 5th octaves and 87.4 % in the 6th octave. Conclusions. The acoustic monitoring device Trembita-Corona demonstrates high specificity, sensitivity and positive predictive value and negative predictive value at given prevalence..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:18 |
---|---|
Enthalten in: |
Zdorovʹe Rebenka - 18(2023), 4, Seite 262-266 |
Sprache: |
Englisch ; Ukrainisch |
---|
Beteiligte Personen: |
Yu.V. Marushko [VerfasserIn] |
---|
Links: |
doi.org [kostenfrei] |
---|
Themen: |
Children |
---|
doi: |
10.22141/2224-0551.18.4.2023.1597 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
DOAJ096098120 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ096098120 | ||
003 | DE-627 | ||
005 | 20240413141854.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240413s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.22141/2224-0551.18.4.2023.1597 |2 doi | |
035 | |a (DE-627)DOAJ096098120 | ||
035 | |a (DE-599)DOAJc5ad6b739004461f938560a1fcb9face | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng |a ukr | ||
050 | 0 | |a RJ1-570 | |
100 | 0 | |a Yu.V. Marushko |e verfasserin |4 aut | |
245 | 1 | 0 | |a Sensitivity and specificity of the method of acoustic diagnosis of pneumonia using the acoustic monitoring device Trembita-Corona |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Background. Diagnosis of pneumonia is difficult and requires a comprehensive examination. Respiratory acoustics is currently a promising diagnostic method. The purpose was to evaluate the possibility of pneumonia detection by the average signal power, frequency and amplitude of the acoustic signal using the Trembita-Corona acoustic monitoring device. Materials and methods. Onу hundred and ninety-three children aged from 1 month to 18 years were examined. The children were divided into two groups: group I — 98 patients with community-acquired pneumonia, group II — 95 healthy children. All children were examined using the Trembita-Corona acoustic monitoring device. Results. The sensitivity of the method for detecting pneumonia using the acoustic monitoring device Trembita-Corona according to the average signal power in the 4th, 5th and 6th octaves is from 90.8 to 99 %, and the specificity is from 87.4 to 100 %. The sensitivity of the method for detecting pneumonia using the acoustic monitoring device Trembita-Corona according to the frequency of the acoustic signal in the 3rd and 5th octaves is more than 60 %, and the specificity is more than 63 % in the 3rd octave and 100 % in the 5th octave, respectively. The sensitivity of the method for detecting pneumonia using the acoustic monitoring device Trembita-Corona according to the amplitude of the acoustic signal in the 4th, 5th and 6th octaves is 88.9, 99.9 and 86.9 %, respectively, and the specificity is 100 % in the 4th and 5th octaves and 87.4 % in the 6th octave. Conclusions. The acoustic monitoring device Trembita-Corona demonstrates high specificity, sensitivity and positive predictive value and negative predictive value at given prevalence. | ||
650 | 4 | |a children | |
650 | 4 | |a community-acquired pneumonia | |
650 | 4 | |a diagnostics | |
650 | 4 | |a trembita-corona acoustic monitoring device | |
653 | 0 | |a Pediatrics | |
700 | 0 | |a O.V. Khomych |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t Zdorovʹe Rebenka |d Zaslavsky O.Yu., 2017 |g 18(2023), 4, Seite 262-266 |w (DE-627)DOAJ000076147 |x 23071168 |7 nnns |
773 | 1 | 8 | |g volume:18 |g year:2023 |g number:4 |g pages:262-266 |
856 | 4 | 0 | |u https://doi.org/10.22141/2224-0551.18.4.2023.1597 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/c5ad6b739004461f938560a1fcb9face |z kostenfrei |
856 | 4 | 0 | |u https://childshealth.zaslavsky.com.ua/index.php/journal/article/view/1597 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2224-0551 |y Journal toc |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2307-1168 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_DOAJ | ||
951 | |a AR | ||
952 | |d 18 |j 2023 |e 4 |h 262-266 |