Performance and reference intervals of thrombin generation test: results from the Brazilian longitudinal study of adult health (ELSA-Brasil). A cross-sectional study

ABSTRACT BACKGROUND: The thrombin generation test (TGT) has shown promise for investigation of hemorrhagic and thrombotic diseases. However, despite its potential, it still needs standardization. Moreover, few studies have established reference values for TGT parameters. In Brazil, these values have not yet been established. OBJECTIVE: To determine TGT performance and reference intervals for TGT parameters in healthy individuals. DESIGN AND SETTING: Cross-sectional study conducted among participants in the Brazilian Longitudinal Study of Adult Health (Estudo Longitudinal de Saúde do Adulto, ELSA-Brasil). METHODS: The reference sample consisted of 620 healthy individuals. The calibrated automated thrombogram (CAT) method, under low and high tissue factor (TF) conditions, was used to assess thrombin generation. Test performance was analyzed using intra and interassay coefficients of variation (CV) and reference intervals were calculated using the nonparametric method proposed by the International Federation of Clinical Chemistry and the Clinical and Laboratory Standards Institute. RESULTS: The intraassay CV ranged from 1.4% to 2.2% and the interassay CV, 6.8% to 14.7%. The reference intervals for TGT parameters under low and high TF conditions were, respectively: lagtime: 3.0-10.3 and 1.4-3.7 min; endogenous thrombin potential (ETP): 1134.6-2517.9 and 1413.6-2658.0 nM.min; normalized ETP: 0.6-1.3 and 0.7-1.4; peak: 103.2-397.7 and 256.4-479.0 nM; normalized peak: 0.3-1.3 and 0.7-1.2; and time-to-peak: 5.6-16.0 and 3.4-6.7 min. These parameters were categorized relative to sex. Conclusion: TGT performance was adequate and the proposed reference intervals were similar to those of other studies. Our findings may be useful for consolidating the TGT, through contributing to its standardization and validation..

Medienart:

E-Artikel

Erscheinungsjahr:

2022

Erschienen:

2022

Enthalten in:

Zur Gesamtaufnahme - year:2022

Enthalten in:

São Paulo Medical Journal - (2022)

Sprache:

Englisch

Beteiligte Personen:

Danyelle Romana Alves Rios [VerfasserIn]
Sandhi Maria Barreto [VerfasserIn]
Letícia Gonçalves Resende Ferreira [VerfasserIn]
Thaís Resende Batista [VerfasserIn]
Ana Paula Ferreira Silva [VerfasserIn]
Wander Valadares de Oliveira Júnior [VerfasserIn]
Chams Bicalho Maluf [VerfasserIn]
Maria das Graças Carvalho [VerfasserIn]
Roberta Carvalho Figueiredo [VerfasserIn]

Links:

doi.org [kostenfrei]
doaj.org [kostenfrei]
www.scielo.br [kostenfrei]
Journal toc [kostenfrei]

Themen:

Calibrated automated thrombogram
Clinical laboratory techniques
Medicine
R
Reference ranges
Reference values
Thrombin
Thrombin generation assay

doi:

10.1590/1516-3180.2021.0425.r1.07102021

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

DOAJ040779041