Breast cancer in dense breasts: comparative diagnostic merits of contrast-enhanced mammography and diffusion-weighted breast MRI

Abstract Background The study was done to compare the value of contrast-enhanced mammography and diffusion-weighted breast MRI in dense breast screening and accurate detection of the breast cancer with correlation of the findings to the histopathological results. The study included 32 female patients having suspicious breast lesions and underwent digital mammography then scheduled for CESM and MRI DW imaging technique. The imaging findings were correlated to the histopathological findings. Results The study was conducted on 40 breast lesions in 32 female patients having dense breasts; they were classified by the digital mammography into ACR C (59.4%) and ACR D (40.6%). By CESM, there were twenty three lesions (57.5%) as mass lesions and thirteen lesions (32.5%) as non-mass lesions. Four lesions (10%) showed no contrast enhancement. According to the lesion characteristics in diffusion-weighted imaging, the breast lesions were classified into thirty three lesions (82.5%) with restricted diffusion and seven lesions (17.5%) with non-restricted diffusion. The study showed a cutoff ADC value to detect the malignant lesions in the dense breasts ≤ 1.1 × 10-3 s/mm2 at b value of 1000 s/mm2 with a sensitivity of 96.77%, specificity of 66.67%, PPV of 96.77%, NPV of 55.55%, and an overall total accuracy of 92.5%. On comparing the diagnostic accuracy of the CESM to that of the DW MRI, the sensitivity of DW MRI (96.77%) was higher than that of CESM (90.32%). The specificity of DW MRI (66.67%) was higher than that of CESM (33.33%). Total accuracy of DW MRI was higher than that of CESM; they were 90% and 77.5%, respectively. Also, PPV and NPV of DW MRI were 90.91 and 85.71% as compared with 82.35 and 50.00% in CESM, respectively. When comparing the sensitivity of CESM to DW MRI in the detection of multiple breast lesions, they were 88.8 and 100%, respectively. Conclusion CESM is a useful technique in identification of hidden lesions in mammographically dense breasts. DW MRI is a fast, unenhanced modality that can be used as a breast cancer screening modality. CESM and DWI demonstrated good overall diagnostic accuracy in dense breast patients; however, DW MRI has a higher diagnostic accuracy than CESM for the detection of malignant breast lesions and their multiplicity..

Medienart:

E-Artikel

Erscheinungsjahr:

2021

Erschienen:

2021

Enthalten in:

Zur Gesamtaufnahme - volume:52

Enthalten in:

The Egyptian Journal of Radiology and Nuclear Medicine - 52(2021), 1, Seite 13

Sprache:

Englisch

Beteiligte Personen:

Reham Anwar [VerfasserIn]
Mohamed Amr Farouk [VerfasserIn]
Wafaa Raafat Abdel Hamid [VerfasserIn]
Amal Amin Abu El Maati [VerfasserIn]
Hanan Eissa [VerfasserIn]

Links:

doi.org [kostenfrei]
doaj.org [kostenfrei]
doi.org [kostenfrei]
Journal toc [kostenfrei]

Themen:

Apparent diffusion coefficient (ADC)
Breast cancer
Contrast-enhanced spectral mammography (CESM)
Dense breasts
Diffusion-weighted MRI (DW MRI)
Medical physics. Medical radiology. Nuclear medicine

doi:

10.1186/s43055-021-00442-z

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

DOAJ016206363