Klasifikasi Sel Darah Putih Menggunakan Metode Support Vector Machine (SVM) Berbasis Pengolahan Citra Digital
White blood cells are classified into five types (basophils, eosinophils, neutrophils, lymphocytes and monocytes) with additional classes lymphoblast cells from microscope images are processed. By applying image processing, image its white blood cells extracted using the Histogram Oriented Gradient. Feature extraction results obtained then classified using Support Vector Machine method by comparing the results of two different kernel parameters: kernel Linear and kernel Radial Basis Function (RBF). Classification evaluated with these parameters: Accuracy, specificity, and sensitivity. Obtained an accuracy of 72.26% from the detection of white blood cells in the microscope image. The average value of microscope images of patients and different kernel every white blood cells (monocytes, basophils, neutrophils, eosinophils, lymphocytes and lymphoblast) were evaluated with these parameters. Results of the study show the classification system has an average value of 82.20% accuracy (RBF Patient 1), 81.63% (RBF Patient 2) and 78.73% (Linear Patient 1), 79.55% (Linear Patient 2 ), then the value of specificity of 89.91% (RBF patient 1), 92.18% (RBF patient 2) and 88.06% (Linear patient 1), 91.34% (Linear patient 2), and sensitivity values 15 , 45% (RBF patient 1), 12.97% (RBF patient 2) and 13.33% (Linear patient 1), 12.50% (Linear patient 2)..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2017 |
---|---|
Erschienen: |
2017 |
Enthalten in: |
Zur Gesamtaufnahme - volume:7 |
---|---|
Enthalten in: |
IJEIS (Indonesian Journal of Electronics and Instrumentation Systems) - 7(2017), 1, Seite 25-36 |
Sprache: |
Indonesisch |
---|
Beteiligte Personen: |
Bhima Caraka [VerfasserIn] |
---|
Links: |
doi.org [kostenfrei] |
---|
doi: |
10.22146/ijeis.15420 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
DOAJ012951021 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ012951021 | ||
003 | DE-627 | ||
005 | 20230503074335.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230225s2017 xx |||||o 00| ||ind c | ||
024 | 7 | |a 10.22146/ijeis.15420 |2 doi | |
035 | |a (DE-627)DOAJ012951021 | ||
035 | |a (DE-599)DOAJeb8003c28dc443ef9345d450b139c473 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a ind | ||
050 | 0 | |a TK7800-8360 | |
050 | 0 | |a TJ212-225 | |
100 | 0 | |a Bhima Caraka |e verfasserin |4 aut | |
245 | 1 | 0 | |a Klasifikasi Sel Darah Putih Menggunakan Metode Support Vector Machine (SVM) Berbasis Pengolahan Citra Digital |
264 | 1 | |c 2017 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a White blood cells are classified into five types (basophils, eosinophils, neutrophils, lymphocytes and monocytes) with additional classes lymphoblast cells from microscope images are processed. By applying image processing, image its white blood cells extracted using the Histogram Oriented Gradient. Feature extraction results obtained then classified using Support Vector Machine method by comparing the results of two different kernel parameters: kernel Linear and kernel Radial Basis Function (RBF). Classification evaluated with these parameters: Accuracy, specificity, and sensitivity. Obtained an accuracy of 72.26% from the detection of white blood cells in the microscope image. The average value of microscope images of patients and different kernel every white blood cells (monocytes, basophils, neutrophils, eosinophils, lymphocytes and lymphoblast) were evaluated with these parameters. Results of the study show the classification system has an average value of 82.20% accuracy (RBF Patient 1), 81.63% (RBF Patient 2) and 78.73% (Linear Patient 1), 79.55% (Linear Patient 2 ), then the value of specificity of 89.91% (RBF patient 1), 92.18% (RBF patient 2) and 88.06% (Linear patient 1), 91.34% (Linear patient 2), and sensitivity values 15 , 45% (RBF patient 1), 12.97% (RBF patient 2) and 13.33% (Linear patient 1), 12.50% (Linear patient 2). | ||
650 | 4 | |a White blood cells, Feature extraction, Histogram oriented gradient, Classification, Support vector machine, Linear, Radial basis function | |
653 | 0 | |a Electronics | |
653 | 0 | |a Control engineering systems. Automatic machinery (General) | |
700 | 0 | |a Bakhtiar Alldino Ardi Sumbodo |e verfasserin |4 aut | |
700 | 0 | |a Ika Candradewi |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t IJEIS (Indonesian Journal of Electronics and Instrumentation Systems) |d Universitas Gadjah Mada, 2017 |g 7(2017), 1, Seite 25-36 |w (DE-627)DOAJ000106461 |x 24607681 |7 nnns |
773 | 1 | 8 | |g volume:7 |g year:2017 |g number:1 |g pages:25-36 |
856 | 4 | 0 | |u https://doi.org/10.22146/ijeis.15420 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/eb8003c28dc443ef9345d450b139c473 |z kostenfrei |
856 | 4 | 0 | |u https://jurnal.ugm.ac.id/ijeis/article/view/15420 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2088-3714 |y Journal toc |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2460-7681 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_DOAJ | ||
912 | |a SSG-OLC-PHA | ||
951 | |a AR | ||
952 | |d 7 |j 2017 |e 1 |h 25-36 |