Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube.
AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation. RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation. CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2001 |
---|---|
Erschienen: |
2001 |
Enthalten in: |
Zur Gesamtaufnahme - volume:47 |
---|---|
Enthalten in: |
Journal of Postgraduate Medicine - 47(2001), 3, Seite 181-4 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ghai B [VerfasserIn] |
---|
Links: |
doaj.org [kostenfrei] |
---|
Themen: |
Adult |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
DOAJ009335501 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ009335501 | ||
003 | DE-627 | ||
005 | 20230310020151.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230225s2001 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)DOAJ009335501 | ||
035 | |a (DE-599)DOAJ21d56c822b2e46989d9a6d18770a8fbf | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 0 | |a Ghai B |e verfasserin |4 aut | |
245 | 1 | 0 | |a Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube. |
264 | 1 | |c 2001 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation. RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation. CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation. | ||
650 | 4 | |a Adult | |
650 | 4 | |a Blood Pressure | |
650 | 4 | |a Comparative Study | |
650 | 4 | |a Female | |
650 | 4 | |a Heart Rate | |
650 | 4 | |a Human | |
650 | 4 | |a Intraocular Pressure | |
650 | 4 | |a physiology | |
650 | 4 | |a Intubation | |
650 | 4 | |a Intratracheal | |
650 | 4 | |a adverse effects | |
650 | 4 | |a Laryngeal Masks | |
650 | 4 | |a Male | |
650 | 4 | |a Middle Age | |
653 | 0 | |a Medicine | |
653 | 0 | |a R | |
700 | 0 | |a Sharma A |e verfasserin |4 aut | |
700 | 0 | |a Akhtar S |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t Journal of Postgraduate Medicine |d Wolters Kluwer Medknow Publications, 2003 |g 47(2001), 3, Seite 181-4 |w (DE-627)DOAJ00006470X |x 09722823 |7 nnns |
773 | 1 | 8 | |g volume:47 |g year:2001 |g number:3 |g pages:181-4 |
856 | 4 | 0 | |u https://doaj.org/article/21d56c822b2e46989d9a6d18770a8fbf |z kostenfrei |
856 | 4 | 0 | |u http://www.jpgmonline.com/article.asp?issn=0022-3859;year=2001;volume=47;issue=3;spage=181;epage=4;aulast=Ghai |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/0022-3859 |y Journal toc |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/0972-2823 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_DOAJ | ||
951 | |a AR | ||
952 | |d 47 |j 2001 |e 3 |h 181-4 |