Development of a Robotic Minimally Invasive Pathway for Cochlear Implantation : Development of a Robotic Minimally Invasive Pathway for Cochlear Implantation
The ROSA robot coupled to the O-Arm scanner will guide the milling to the round window, whose path has been previously modeled, with the identification of the facial nerve. Milling will be done in 2 stages with a CT (computerised tomography scan) and electromyographic verification of the facial nerve. The insertion of the implant will be performed manually under endoscopic control. The preoperative and postoperative course of the patient will be identical..
Medienart: |
Klinische Studie |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
ClinicalTrials.gov - (2023) vom: 13. Sept. Zur Gesamtaufnahme - year:2023 |
---|
Sprache: |
Englisch |
---|
Links: |
Volltext [kostenfrei] |
---|
Themen: |
610 |
---|
Anmerkungen: |
Source: Link to the current ClinicalTrials.gov record., First posted: August 7, 2019, Last downloaded: ClinicalTrials.gov processed this data on September 20, 2023, Last updated: September 20, 2023 |
---|
Study ID: |
NCT04048239 |
---|---|
Veröffentlichungen zur Studie: |
|
fisyears: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
CTG003130630 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | CTG003130630 | ||
003 | DE-627 | ||
005 | 20230920010453.0 | ||
007 | cr uuu---uuuuu | ||
008 | 210408s2023 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)CTG003130630 | ||
035 | |a (UBBS_Klinische_Studien)NCT04048239 | ||
035 | |a (UBBS_Klinische_Studien)PI2019_843_0004 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Development of a Robotic Minimally Invasive Pathway for Cochlear Implantation |b Development of a Robotic Minimally Invasive Pathway for Cochlear Implantation |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Source: Link to the current ClinicalTrials.gov record., First posted: August 7, 2019, Last downloaded: ClinicalTrials.gov processed this data on September 20, 2023, Last updated: September 20, 2023 | ||
520 | |a The ROSA robot coupled to the O-Arm scanner will guide the milling to the round window, whose path has been previously modeled, with the identification of the facial nerve. Milling will be done in 2 stages with a CT (computerised tomography scan) and electromyographic verification of the facial nerve. The insertion of the implant will be performed manually under endoscopic control. The preoperative and postoperative course of the patient will be identical. | ||
650 | 2 | |a Hearing Loss | |
650 | 2 | |a Hearing Loss, Sensorineural | |
650 | 4 | |a Study Type: Interventional | |
650 | 4 | |a Recruitment Status: Completed | |
650 | 4 | |a 610 | |
773 | 0 | 8 | |i Enthalten in |t ClinicalTrials.gov |g (2023) vom: 13. Sept. |
773 | 1 | 8 | |g year:2023 |g day:13 |g month:09 |
856 | 4 | 0 | |u https://clinicaltrials.gov/show/NCT04048239 |z kostenfrei |3 Volltext |
912 | |a GBV_CTG | ||
951 | |a AR | ||
952 | |j 2023 |b 13 |c 09 |