Super-resolved linear fluorescence localization microscopy using photostable fluorophores : a virtual microscopy study / Udo Birk, Aleksander Szczurek, Christoph Cremer
Current approaches to overcome the conventional limit of the resolution potential of light microscopy (of about 200 nm for visible light), often suffer from non-linear effects, which render the quantification of the image intensities in the reconstructions difficult, and also affect the quantification of the biological structure under investigation. As an attempt to face these difficulties, we discuss a particular method of localization microscopy which is based on photostable fluorescent dyes. The proposed method can potentially be implemented as a fast alternative for quantitative localization microscopy, circumventing the need for the acquisition of thousands of image frames and complex, highly dye-specific imaging buffers. Although the need for calibration remains in order to extract quantitative data (such as the number of emitters), multispectral approaches are largely facilitated due to the much less stringent requirements on imaging buffers. Furthermore, multispectral acquisitions can be readily obtained using commercial instrumentation such as e.g. the conventional confocal laser scanning microscope..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
21 July 2017 2017 |
---|---|
Erschienen: |
21 July 2017 |
Enthalten in: |
Zur Gesamtaufnahme - volume:404 |
---|---|
Enthalten in: |
Optics communications - 404(2017), Seite 42-50 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Birk, Udo J., 1971- [VerfasserIn] |
---|
Links: |
---|
Themen: |
Linear fluorescence microscopy |
---|
Anmerkungen: |
Available online 21 July 2017 Gesehen am 14.08.2018 |
---|
Umfang: |
9 |
---|
doi: |
10.1016/j.optcom.2017.06.078 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
1580018246 |
---|
LEADER | 01000caa a2200265 4500 | ||
---|---|---|---|
001 | 1580018246 | ||
003 | DE-627 | ||
005 | 20230427065639.0 | ||
007 | cr uuu---uuuuu | ||
008 | 180814s2017 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.optcom.2017.06.078 |2 doi | |
035 | |a (DE-627)1580018246 | ||
035 | |a (DE-576)510018246 | ||
035 | |a (DE-599)BSZ510018246 | ||
035 | |a (OCoLC)1341016911 | ||
040 | |a DE-627 |b ger |c DE-627 |e rda | ||
041 | |a eng | ||
100 | 1 | |a Birk, Udo J. |d 1971- |e verfasserin |0 (DE-588)138128154 |0 (DE-627)696360675 |0 (DE-576)306577852 |4 aut | |
245 | 1 | 0 | |a Super-resolved linear fluorescence localization microscopy using photostable fluorophores |b a virtual microscopy study |c Udo Birk, Aleksander Szczurek, Christoph Cremer |
264 | 1 | |c 21 July 2017 | |
300 | |a 9 | ||
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Available online 21 July 2017 | ||
500 | |a Gesehen am 14.08.2018 | ||
520 | |a Current approaches to overcome the conventional limit of the resolution potential of light microscopy (of about 200 nm for visible light), often suffer from non-linear effects, which render the quantification of the image intensities in the reconstructions difficult, and also affect the quantification of the biological structure under investigation. As an attempt to face these difficulties, we discuss a particular method of localization microscopy which is based on photostable fluorescent dyes. The proposed method can potentially be implemented as a fast alternative for quantitative localization microscopy, circumventing the need for the acquisition of thousands of image frames and complex, highly dye-specific imaging buffers. Although the need for calibration remains in order to extract quantitative data (such as the number of emitters), multispectral approaches are largely facilitated due to the much less stringent requirements on imaging buffers. Furthermore, multispectral acquisitions can be readily obtained using commercial instrumentation such as e.g. the conventional confocal laser scanning microscope. | ||
650 | 4 | |a Linear fluorescence microscopy | |
650 | 4 | |a Photostable dyes | |
650 | 4 | |a SMLM | |
650 | 4 | |a Super-resolution fluorescence microscopy | |
700 | 1 | |a Szczurek, Aleksander |d 1989- |e verfasserin |0 (DE-588)1128250667 |0 (DE-627)882695355 |0 (DE-576)48581353X |4 aut | |
700 | 1 | |a Cremer, Christoph |d 1944- |e verfasserin |0 (DE-588)134078799 |0 (DE-627)560220626 |0 (DE-576)300297890 |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Optics communications |d Amsterdam : [Verlag nicht ermittelbar], 1969 |g 404(2017), Seite 42-50 |h Online-Ressource |w (DE-627)266889247 |w (DE-600)1468811-6 |w (DE-576)07596239X |x 1873-0310 |7 nnns |
773 | 1 | 8 | |g volume:404 |g year:2017 |g pages:42-50 |g extent:9 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.optcom.2017.06.078 |x Verlag |x Resolving-System |3 Volltext |
856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0030401817305540 |x Verlag |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ILN_2013 | ||
912 | |a ISIL_DE-16-250 | ||
912 | |a SYSFLAG_1 | ||
912 | |a GBV_KXP | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2039 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2070 | ||
912 | |a GBV_ILN_2086 | ||
912 | |a GBV_ILN_2098 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2116 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4333 | ||
936 | u | w | |d 404 |j 2017 |h 42-50 |g 9 |
951 | |a AR | ||
952 | |d 404 |j 2017 |h 42-50 |g 9 | ||
980 | |2 2013 |1 01 |x DE-16-250 |b 302232376X |c 00 |f --%%-- |d --%%-- |e --%%-- |j --%%-- |y l01 |z 14-08-18 | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 00 |s s |a hd2017 | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 01 |s s |0 (DE-627)1410508463 |a wissenschaftlicher Artikel (Zeitschrift) | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 02 |s s |a per_3 | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 03 |s s |a s_9 | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 04 |s p |0 (DE-627)1578540283 |a Birk, Udo J. | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 04 |s k |0 (DE-627)1416822720 |a Extern | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 04 |s s |0 (DE-627)1410501914 |a Verfasser | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 04 |s s |a pos_1 | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 05 |s p |0 (DE-627)1430444177 |a Cremer, Christoph | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 05 |s k |0 (DE-627)1416535438 |a Kirchhoff-Institut für Physik (KIP) | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 05 |s k |0 (DE-627)1416535624 |a Institut für Pharmazie und Molekulare Biotechnologie (IPMB) | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 05 |s s |0 (DE-627)1410501914 |a Verfasser | ||
982 | |2 2013 |1 01 |x DE-16-250 |8 05 |s s |a pos_3 |