Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays
Abstract Serologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy. Several logistical and infrastructure challenges limit access to SARS-CoV-2 serologic testing. Dried blood spot (DBS) samples have been used for serology testing of various diseases in resource-limited settings. We examined the use of DBS samples and capillary blood (fingerstick) plasma collected in Microtainer tubes for SARS-CoV-2 testing with the automated Abbott ARCHITECT™ SARS-CoV-2 IgG (List 6R86) and IgM assays and use of venous whole blood with a prototype PANBIO™ rapid point-of-care lateral flow SARS-CoV-2 IgG assay. The ARCHITECT™ SARS-CoV-2 IgG assay was initially optimized for use with DBS, venous and capillary plasma, and venous whole blood collected from patients with symptoms and PCR-confirmed COVID-19 and negative asymptomatic controls. Assay linearity and reproducibility was confirmed with 3 contrived DBS samples, with sample stability and signal recovery after 14 days at room temperature. ARCHITECT™ SARS-CoV-2 IgG and IgM assay results showed high concordance between fingerstick DBS and venous DBS samples, and between fingerstick DBS and venous whole blood samples (n=61). Discordant results were seen in 3 participants (2 IgG, 1 IgM) who were in the process of seroreversion at the time of sample collection and had results near the assay cutoff. Use of fingerstick plasma collected in Microtainer tubes (n=109) showed 100% concordant results (R2=0.997) with matched patient venous plasma on the ARCHITECT™ SARS-CoV-2 IgG assay. High concordance of assay results (92.9% positive, 100% negative) was also observed for the PANBIO™ SARS-CoV-2 IgG assay compared to the ARCHITECT™ SARS-CoV-2 IgG assay run with matched venous plasma (n=61). Fingerstick DBS and plasma samples are easy and inexpensive to collect and, along with the use of rapid point-of-care testing platforms, will expand access to SARS-CoV-2 serology testing, particularly in resource-limited areas..
Medienart: |
Preprint |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
bioRxiv.org - (2021) vom: 15. Dez. Zur Gesamtaufnahme - year:2021 |
---|
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Anderson, Mark [VerfasserIn] |
---|
Links: |
---|
doi: |
10.1101/2021.04.16.21255130 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
XBI020376049 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | XBI020376049 | ||
003 | DE-627 | ||
005 | 20230429091223.0 | ||
007 | cr uuu---uuuuu | ||
008 | 210419s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1101/2021.04.16.21255130 |2 doi | |
035 | |a (DE-627)XBI020376049 | ||
035 | |a (biorXiv)10.1101/2021.04.16.21255130 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | |a 570 |q DE-84 | |
100 | 1 | |a Anderson, Mark |e verfasserin |4 aut | |
245 | 1 | 0 | |a Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Abstract Serologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy. Several logistical and infrastructure challenges limit access to SARS-CoV-2 serologic testing. Dried blood spot (DBS) samples have been used for serology testing of various diseases in resource-limited settings. We examined the use of DBS samples and capillary blood (fingerstick) plasma collected in Microtainer tubes for SARS-CoV-2 testing with the automated Abbott ARCHITECT™ SARS-CoV-2 IgG (List 6R86) and IgM assays and use of venous whole blood with a prototype PANBIO™ rapid point-of-care lateral flow SARS-CoV-2 IgG assay. The ARCHITECT™ SARS-CoV-2 IgG assay was initially optimized for use with DBS, venous and capillary plasma, and venous whole blood collected from patients with symptoms and PCR-confirmed COVID-19 and negative asymptomatic controls. Assay linearity and reproducibility was confirmed with 3 contrived DBS samples, with sample stability and signal recovery after 14 days at room temperature. ARCHITECT™ SARS-CoV-2 IgG and IgM assay results showed high concordance between fingerstick DBS and venous DBS samples, and between fingerstick DBS and venous whole blood samples (n=61). Discordant results were seen in 3 participants (2 IgG, 1 IgM) who were in the process of seroreversion at the time of sample collection and had results near the assay cutoff. Use of fingerstick plasma collected in Microtainer tubes (n=109) showed 100% concordant results (R2=0.997) with matched patient venous plasma on the ARCHITECT™ SARS-CoV-2 IgG assay. High concordance of assay results (92.9% positive, 100% negative) was also observed for the PANBIO™ SARS-CoV-2 IgG assay compared to the ARCHITECT™ SARS-CoV-2 IgG assay run with matched venous plasma (n=61). Fingerstick DBS and plasma samples are easy and inexpensive to collect and, along with the use of rapid point-of-care testing platforms, will expand access to SARS-CoV-2 serology testing, particularly in resource-limited areas. | ||
700 | 1 | |a Holzmayer, Vera |e verfasserin |4 aut | |
700 | 1 | |a Vallari, Ana |e verfasserin |4 aut | |
700 | 1 | |a Taylor, Russell |e verfasserin |4 aut | |
700 | 1 | |a Moy, James |e verfasserin |4 aut | |
700 | 1 | |a Cloherty, Gavin |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t bioRxiv.org |g (2021) vom: 15. Dez. |
773 | 1 | 8 | |g year:2021 |g day:15 |g month:12 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.jcv.2021.104855 |z lizenzpflichtig |3 Volltext |
856 | 4 | 0 | |u http://dx.doi.org/10.1101/2021.04.16.21255130 |z kostenfrei |3 Volltext |
912 | |a GBV_XBI | ||
912 | |a SSG-OLC-PHA | ||
951 | |a AR | ||
952 | |j 2021 |b 15 |c 12 | ||
953 | |2 045F |a 570 |