Effect of MRI-based semiautomatic size-assessment in cerebral metastases on the RANO-BM classification
Aim Evaluation of a semiautomatic software algorithm for magnetic resonance imaging (MRI)-based assessment of cerebral metastases in cancer patients. Material and Methods Brain metastases (n = 131) in 38 patients, assessed by contrast-enhanced MRI, were retrospectively evaluated at two timepoints (baseline, follow-up) by two experienced neuroradiologists in a blinded manner. The response assessment in neuro-oncology (RANO) criteria for brain metastases (RANO-BM) were applied by means of a software (autoRANO-BM) as well as manually (manRANO-BM) at an interval of 3 weeks. Results The average diameter of metastases was 12.03 mm (SD ± 6.66 mm) for manRANO-BM and 13.97 mm (SD ± 7.76 mm) for autoRANO-BM. Diameter figures were higher when using semiautomatic measurements (median = 11.8 mm) as compared to the manual ones (median = 10.2 mm; p = 0.000). Correlation coefficients for intra-observer variability were 0.993 (autoRANO-BM) and 0.979 (manRANO-BM). The interobserver variability (R1/R2) was 0.936/0.965 for manRANO-BM and 0.989/0.998 for autoRANO-BM. A total of 19 lesions (15%) were classified differently when using semiautomatic measurements. In 14 cases with suspected disease progression by manRANO-BM a stable course was found according to autoRANO-BM. Conclusion Computerized measuring techniques can aid in the assessment of cerebral metastases by reducing examiner-dependent effects and may consequently result in a different classification according to RANO-BM criteria..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2019 |
---|---|
Erschienen: |
2019 |
Enthalten in: |
Zur Gesamtaufnahme - volume:30 |
---|---|
Enthalten in: |
Clinical neuroradiology - 30(2019), 2 vom: 13. Juni, Seite 263-270 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Bauknecht, Hans-Christian [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
BKL: | |
---|---|
Themen: |
Cerebral metastases |
doi: |
10.1007/s00062-019-00785-1 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
SPR040202119 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | SPR040202119 | ||
003 | DE-627 | ||
005 | 20230519132257.0 | ||
007 | cr uuu---uuuuu | ||
008 | 201007s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00062-019-00785-1 |2 doi | |
035 | |a (DE-627)SPR040202119 | ||
035 | |a (SPR)s00062-019-00785-1-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q ASE |
082 | 0 | 4 | |a 610 |q ASE |
084 | |a 44.64 |2 bkl | ||
084 | |a 44.90 |2 bkl | ||
100 | 1 | |a Bauknecht, Hans-Christian |e verfasserin |4 aut | |
245 | 1 | 0 | |a Effect of MRI-based semiautomatic size-assessment in cerebral metastases on the RANO-BM classification |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Aim Evaluation of a semiautomatic software algorithm for magnetic resonance imaging (MRI)-based assessment of cerebral metastases in cancer patients. Material and Methods Brain metastases (n = 131) in 38 patients, assessed by contrast-enhanced MRI, were retrospectively evaluated at two timepoints (baseline, follow-up) by two experienced neuroradiologists in a blinded manner. The response assessment in neuro-oncology (RANO) criteria for brain metastases (RANO-BM) were applied by means of a software (autoRANO-BM) as well as manually (manRANO-BM) at an interval of 3 weeks. Results The average diameter of metastases was 12.03 mm (SD ± 6.66 mm) for manRANO-BM and 13.97 mm (SD ± 7.76 mm) for autoRANO-BM. Diameter figures were higher when using semiautomatic measurements (median = 11.8 mm) as compared to the manual ones (median = 10.2 mm; p = 0.000). Correlation coefficients for intra-observer variability were 0.993 (autoRANO-BM) and 0.979 (manRANO-BM). The interobserver variability (R1/R2) was 0.936/0.965 for manRANO-BM and 0.989/0.998 for autoRANO-BM. A total of 19 lesions (15%) were classified differently when using semiautomatic measurements. In 14 cases with suspected disease progression by manRANO-BM a stable course was found according to autoRANO-BM. Conclusion Computerized measuring techniques can aid in the assessment of cerebral metastases by reducing examiner-dependent effects and may consequently result in a different classification according to RANO-BM criteria. | ||
650 | 4 | |a Cerebral metastases |7 (dpeaa)DE-He213 | |
650 | 4 | |a Semiautomatic measurement |7 (dpeaa)DE-He213 | |
650 | 4 | |a RECIST |7 (dpeaa)DE-He213 | |
650 | 4 | |a Response group |7 (dpeaa)DE-He213 | |
650 | 4 | |a Radiooncological imaging |7 (dpeaa)DE-He213 | |
700 | 1 | |a Klingebiel, Randolf |e verfasserin |4 aut | |
700 | 1 | |a Hein, Patrick |e verfasserin |4 aut | |
700 | 1 | |a Wolf, Claudia |e verfasserin |4 aut | |
700 | 1 | |a Bornemann, Lars |e verfasserin |4 aut | |
700 | 1 | |a Siebert, Eberhard |e verfasserin |4 aut | |
700 | 1 | |a Bohner, Georg |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Clinical neuroradiology |d München : Urban & Vogel, 2006 |g 30(2019), 2 vom: 13. Juni, Seite 263-270 |w (DE-627)SPR000464880 |w (DE-600)2232347-8 |x 1869-1447 |7 nnns |
773 | 1 | 8 | |g volume:30 |g year:2019 |g number:2 |g day:13 |g month:06 |g pages:263-270 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00062-019-00785-1 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_SPRINGER | ||
912 | |a SSG-OLC-PHA | ||
936 | b | k | |a 44.64 |q ASE |
936 | b | k | |a 44.90 |q ASE |
951 | |a AR | ||
952 | |d 30 |j 2019 |e 2 |b 13 |c 06 |h 263-270 |