Rapid Bolus Administration Does not Increase The Extravasation Rate of Albumin: A Randomized Controlled Trial in The Endotoxemic Pig
ABSTRACTSome experimental data suggest that rapid bolus administration of albumin causes less plasma-expanding effects than slow, continuous infusion. To determine whether rapid bolus administration, in comparison with slow infusion, results in greater extravasation of albumin in experimental septic shock we performed a randomized controlled trial with 32 endotoxemic pigs. The animals were monitored and ventilated with standard intensive care equipment and given 10 mL × kg 5% albumin labeled with Technetium-99m, either as a rapid 15-min bolus (Bolus group, n = 16) or as a 2-h infusion (Infusion group, n = 16). Radioactivity was monitored in plasma, extracellular microdialysate, and urine for 6 h. Physiological parameters were monitored hourly. Radioactivity in the liver, spleen, kidney, and lung was analyzed post mortem.The plasma area under the curve activity0–6 h was 4.4 ± 0.9 × 10 in the Bolus group and 4.4 ± 1.1 × 10 counts × min × mL × h in the Infusion group. Blood hemoglobin levels increased in both groups, suggesting severe capillary leakage. Yet, there were no group differences in albumin radioactivity in plasma, muscle tissue, urine, or in the post-mortem analysis of the organs. Following albumin administration, circulatory and respiratory parameters were similar in the two groups.In conclusion, the present results suggest that albumin might be given as a bolus without leading to increased extravasation of albumin, in contrast to previous animal experiments in rodents..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2017 |
---|---|
Erschienen: |
2017 |
Enthalten in: |
Zur Gesamtaufnahme - volume:47 |
---|---|
Enthalten in: |
Shock - 47(2017), 4, Seite 514-519 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
von Seth, Magnus [VerfasserIn] |
---|
Links: |
---|
doi: |
10.1097/SHK.0000000000000761 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC1993413456 |
---|
LEADER | 01000caa a2200265 4500 | ||
---|---|---|---|
001 | OLC1993413456 | ||
003 | DE-627 | ||
005 | 20230516001156.0 | ||
007 | tu | ||
008 | 170512s2017 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1097/SHK.0000000000000761 |2 doi | |
028 | 5 | 2 | |a PQ20170901 |
035 | |a (DE-627)OLC1993413456 | ||
035 | |a (DE-599)GBVOLC1993413456 | ||
035 | |a (PRQ)c1911-45274f893d50870e391ee4a08bc899bdf58993f1c025d039ee0f4f282b17ead80 | ||
035 | |a (KEY)0244083020170000047000400514rapidbolusadministrationdoesnotincreasetheextravas | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q ZDB |
100 | 1 | |a von Seth, Magnus |e verfasserin |4 aut | |
245 | 1 | 0 | |a Rapid Bolus Administration Does not Increase The Extravasation Rate of Albumin: A Randomized Controlled Trial in The Endotoxemic Pig |
264 | 1 | |c 2017 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
520 | |a ABSTRACTSome experimental data suggest that rapid bolus administration of albumin causes less plasma-expanding effects than slow, continuous infusion. To determine whether rapid bolus administration, in comparison with slow infusion, results in greater extravasation of albumin in experimental septic shock we performed a randomized controlled trial with 32 endotoxemic pigs. The animals were monitored and ventilated with standard intensive care equipment and given 10 mL × kg 5% albumin labeled with Technetium-99m, either as a rapid 15-min bolus (Bolus group, n = 16) or as a 2-h infusion (Infusion group, n = 16). Radioactivity was monitored in plasma, extracellular microdialysate, and urine for 6 h. Physiological parameters were monitored hourly. Radioactivity in the liver, spleen, kidney, and lung was analyzed post mortem.The plasma area under the curve activity0–6 h was 4.4 ± 0.9 × 10 in the Bolus group and 4.4 ± 1.1 × 10 counts × min × mL × h in the Infusion group. Blood hemoglobin levels increased in both groups, suggesting severe capillary leakage. Yet, there were no group differences in albumin radioactivity in plasma, muscle tissue, urine, or in the post-mortem analysis of the organs. Following albumin administration, circulatory and respiratory parameters were similar in the two groups.In conclusion, the present results suggest that albumin might be given as a bolus without leading to increased extravasation of albumin, in contrast to previous animal experiments in rodents. | ||
540 | |a Nutzungsrecht: © 2017 by the Shock Society | ||
700 | 1 | |a Lipcsey, Miklós |4 oth | |
700 | 1 | |a Engström, Peter |4 oth | |
700 | 1 | |a Larsson, Anders |4 oth | |
700 | 1 | |a Hillered, Lars |4 oth | |
700 | 1 | |a Maripuu, Enn |4 oth | |
700 | 1 | |a Widström, Charles |4 oth | |
700 | 1 | |a Sjölin, Jan |4 oth | |
773 | 0 | 8 | |i Enthalten in |t Shock |d Hagerstown, Md. : Lippincott, Williams & Wilkins, 1994 |g 47(2017), 4, Seite 514-519 |w (DE-627)182197050 |w (DE-600)1185432-7 |w (DE-576)038888041 |x 1073-2322 |7 nnns |
773 | 1 | 8 | |g volume:47 |g year:2017 |g number:4 |g pages:514-519 |
856 | 4 | 1 | |u http://dx.doi.org/10.1097/SHK.0000000000000761 |3 Volltext |
856 | 4 | 2 | |u http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-305826 |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-PHA | ||
912 | |a SSG-OLC-DE-84 | ||
912 | |a GBV_ILN_4219 | ||
951 | |a AR | ||
952 | |d 47 |j 2017 |e 4 |h 514-519 |