Phenol red as electrochemical indicator for highly sensitive quantification of SARS-CoV-2 by loop-mediated isothermal amplification detection
Copyright © 2023. Published by Elsevier B.V..
The current COVID-19 pandemic has made patent the need for rapid and cost-effective diagnostic tests, crucial for future infectious outbreaks. Loop-mediated isothermal amplification (LAMP) is a promising and decentralized alternative to qPCR. In this work we have developed a sensitive, fast, and simple innovative methodology for quantification of SARS-CoV-2 RNA copies, combining reverse-transcription LAMP with electrochemical detection. This is based on the oxidation of phenol red (PR), a visual and electroactive LAMP indicator, which oxidation peak potential (Ep) changes with the progress of the LAMP reaction. Using that Ep shift as analytical signal, a calibration curve was obtained for fragment N1 copies of SARS-CoV2 (which provided better results than N or S fragments), with a potential shift of 16.2 mV per order of magnitude, and a practical limit of detection of 21 copies·μL-1. Moreover, the precision of Ep is excellent (RSD < 2%): 557 ± 5 mV for negative and 602 ± 7 mV for positive (2148 N fragment RNA copies·µL-1·-1) LAMP controls. This methodology has been applied to the analysis of nasopharyngeal swab samples, resulting in total concordance with clinical RT-qPCR results. Advances towards fully decentralization have been achieved by designing and fabricating a small portable heater for isothermal procedures, obtaining comparable results to those from a commercial benchtop thermal cycler.
Media Type: |
Electronic Article |
---|
Year of Publication: |
2024 2023 |
---|---|
Publication: |
2024 |
Contained In: |
To Main Record - volume:266 |
---|---|
Contained In: |
Talanta - 266(2023), Pt 1 vom: 01. Jan., Seite 124963 |
Language: |
English |
---|
Contributors: |
Rioboó-Legaspi, P [Author] |
---|
Links: |
---|
Keywords: |
Electrochemical detection |
---|
Notes: |
Date Completed 20.09.2023 Date Revised 20.09.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.talanta.2023.124963 |
---|
funding: |
|
---|---|
Supporting institution / Project title: |
|
PPN (Catalogue-ID): |
NLM36024212X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM36024212X | ||
003 | DE-627 | ||
005 | 20230920232619.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230731s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.talanta.2023.124963 |2 doi | |
028 | 5 | 2 | |a pubmed23n1479.xml |
035 | |a (DE-627)NLM36024212X | ||
035 | |a (NLM)37517341 | ||
035 | |a (PII)S0039-9140(23)00714-2 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Rioboó-Legaspi, P |e verfasserin |4 aut | |
245 | 1 | 0 | |a Phenol red as electrochemical indicator for highly sensitive quantification of SARS-CoV-2 by loop-mediated isothermal amplification detection |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 20.09.2023 | ||
500 | |a Date Revised 20.09.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023. Published by Elsevier B.V. | ||
520 | |a The current COVID-19 pandemic has made patent the need for rapid and cost-effective diagnostic tests, crucial for future infectious outbreaks. Loop-mediated isothermal amplification (LAMP) is a promising and decentralized alternative to qPCR. In this work we have developed a sensitive, fast, and simple innovative methodology for quantification of SARS-CoV-2 RNA copies, combining reverse-transcription LAMP with electrochemical detection. This is based on the oxidation of phenol red (PR), a visual and electroactive LAMP indicator, which oxidation peak potential (Ep) changes with the progress of the LAMP reaction. Using that Ep shift as analytical signal, a calibration curve was obtained for fragment N1 copies of SARS-CoV2 (which provided better results than N or S fragments), with a potential shift of 16.2 mV per order of magnitude, and a practical limit of detection of 21 copies·μL-1. Moreover, the precision of Ep is excellent (RSD < 2%): 557 ± 5 mV for negative and 602 ± 7 mV for positive (2148 N fragment RNA copies·µL-1·-1) LAMP controls. This methodology has been applied to the analysis of nasopharyngeal swab samples, resulting in total concordance with clinical RT-qPCR results. Advances towards fully decentralization have been achieved by designing and fabricating a small portable heater for isothermal procedures, obtaining comparable results to those from a commercial benchtop thermal cycler | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Electrochemical detection | |
650 | 4 | |a Isothermal amplification (LAMP) | |
650 | 4 | |a Low-cost analysis | |
650 | 4 | |a Phenol red | |
650 | 4 | |a SARS-CoV-2 | |
650 | 4 | |a Screen-printed electrodes | |
650 | 7 | |a RNA, Viral |2 NLM | |
650 | 7 | |a Phenolsulfonphthalein |2 NLM | |
650 | 7 | |a I6G9Y0J1OJ |2 NLM | |
700 | 1 | |a González-López, A |e verfasserin |4 aut | |
700 | 1 | |a Beltrán-Sánchez, J F |e verfasserin |4 aut | |
700 | 1 | |a Cima-Cabal, M D |e verfasserin |4 aut | |
700 | 1 | |a García-Suárez, M M |e verfasserin |4 aut | |
700 | 1 | |a Sánchez, A J García |e verfasserin |4 aut | |
700 | 1 | |a Fernández-Otero, T |e verfasserin |4 aut | |
700 | 1 | |a Haro, J García |e verfasserin |4 aut | |
700 | 1 | |a Costa-Rama, E |e verfasserin |4 aut | |
700 | 1 | |a Fernández-Abedul, M T |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Talanta |d 1966 |g 266(2023), Pt 1 vom: 01. Jan., Seite 124963 |w (DE-627)NLM000143693 |x 1873-3573 |7 nnns |
773 | 1 | 8 | |g volume:266 |g year:2023 |g number:Pt 1 |g day:01 |g month:01 |g pages:124963 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.talanta.2023.124963 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
936 | u | w | |d 266 |j 2023 |e Pt 1 |b 01 |c 01 |h 124963 |
951 | |a AR | ||