Control Release Coating for Urinary Catheters with Enhanced Released Profile for Sustained Antimicrobial Protection
Catheter-associated urinary tract infections (CAUTIs) are common and pose significant costs to healthcare systems. To date, this problem is largely unsolved as commercially available antimicrobial catheters are still lacking in functionality and performance. A prior study by Lim et al. ( Biotechnol. Bioeng. 2018, 115 (8), 2000-2012) reported the development of a novel anhydrous polycaprolactone (PCL) polymer formulation with controlled-release functionality for antimicrobial peptides. In this follow-up study, we developed an improved antimicrobial peptide (AMP)-impregnated poly(ethylene glycol) (PEG)-polycaprolactone (PCL) anhydrous polymer coating for enhanced sustained controlled-release functionality to provide catheters with effective antimicrobial properties. Varying the ratio of PEG and PEG-PCL copolymers resulted in polymers with different morphologies, consequently affecting the AMP release profiles. The optimal coating, formulated with 10% (w/w) PEG-PCL in PCL, achieved a controlled AMP release rate of 31.65 ± 6.85 μg/mL daily for up to 19 days, with a moderate initial burst release. Such profile is desired for antimicrobial coating as the initial burst release acts as a sterilizer to kill the bacteria present in the urinary tract upon insertion, and the subsequent linear release functions as a prophylaxis to deter opportunistic microbial infections. As a proof-of-concept application, our optimized coating was then applied to a commercial silicone catheter for further antibacterial tests. Preliminary results revealed that our coated catheters outperformed commercial silver-based antimicrobial catheters in terms of antimicrobial performance and sustainability, lasting for 4 days. Application of the controlled-release coating also aids in retarding biofilm formation, showing a lower extent of biofilm formation at the end of seven inoculation cycles.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
ACS applied materials & interfaces - 13(2021), 49 vom: 15. Dez., Seite 59263-59274 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Lin, Esther Marie JieRong [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 16.03.2022 Date Revised 16.03.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1021/acsami.1c17697 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM333838335 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM333838335 | ||
003 | DE-627 | ||
005 | 20231225222453.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1021/acsami.1c17697 |2 doi | |
028 | 5 | 2 | |a pubmed24n1112.xml |
035 | |a (DE-627)NLM333838335 | ||
035 | |a (NLM)34846837 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Lin, Esther Marie JieRong |e verfasserin |4 aut | |
245 | 1 | 0 | |a Control Release Coating for Urinary Catheters with Enhanced Released Profile for Sustained Antimicrobial Protection |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 16.03.2022 | ||
500 | |a Date Revised 16.03.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Catheter-associated urinary tract infections (CAUTIs) are common and pose significant costs to healthcare systems. To date, this problem is largely unsolved as commercially available antimicrobial catheters are still lacking in functionality and performance. A prior study by Lim et al. ( Biotechnol. Bioeng. 2018, 115 (8), 2000-2012) reported the development of a novel anhydrous polycaprolactone (PCL) polymer formulation with controlled-release functionality for antimicrobial peptides. In this follow-up study, we developed an improved antimicrobial peptide (AMP)-impregnated poly(ethylene glycol) (PEG)-polycaprolactone (PCL) anhydrous polymer coating for enhanced sustained controlled-release functionality to provide catheters with effective antimicrobial properties. Varying the ratio of PEG and PEG-PCL copolymers resulted in polymers with different morphologies, consequently affecting the AMP release profiles. The optimal coating, formulated with 10% (w/w) PEG-PCL in PCL, achieved a controlled AMP release rate of 31.65 ± 6.85 μg/mL daily for up to 19 days, with a moderate initial burst release. Such profile is desired for antimicrobial coating as the initial burst release acts as a sterilizer to kill the bacteria present in the urinary tract upon insertion, and the subsequent linear release functions as a prophylaxis to deter opportunistic microbial infections. As a proof-of-concept application, our optimized coating was then applied to a commercial silicone catheter for further antibacterial tests. Preliminary results revealed that our coated catheters outperformed commercial silver-based antimicrobial catheters in terms of antimicrobial performance and sustainability, lasting for 4 days. Application of the controlled-release coating also aids in retarding biofilm formation, showing a lower extent of biofilm formation at the end of seven inoculation cycles | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a HHC36 | |
650 | 4 | |a PEG−PCL copolymer | |
650 | 4 | |a antimicrobial peptide | |
650 | 4 | |a coating | |
650 | 4 | |a in vitro release | |
650 | 4 | |a poly(ethylene glycol) (PEG) | |
650 | 4 | |a polycaprolactone (PCL) | |
650 | 7 | |a Anti-Bacterial Agents |2 NLM | |
650 | 7 | |a Antimicrobial Peptides |2 NLM | |
650 | 7 | |a Coated Materials, Biocompatible |2 NLM | |
700 | 1 | |a Lay, Chee Leng |e verfasserin |4 aut | |
700 | 1 | |a Subramanian, Gomathy Sandhya |e verfasserin |4 aut | |
700 | 1 | |a Tan, Wui Siew |e verfasserin |4 aut | |
700 | 1 | |a Leong, Susanna Su Jan |e verfasserin |4 aut | |
700 | 1 | |a Moh, Lionel Chuan Hui |e verfasserin |4 aut | |
700 | 1 | |a Lim, Kaiyang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t ACS applied materials & interfaces |d 2009 |g 13(2021), 49 vom: 15. Dez., Seite 59263-59274 |w (DE-627)NLM194100049 |x 1944-8252 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2021 |g number:49 |g day:15 |g month:12 |g pages:59263-59274 |
856 | 4 | 0 | |u http://dx.doi.org/10.1021/acsami.1c17697 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2021 |e 49 |b 15 |c 12 |h 59263-59274 |