Improved microscopy with ultraviolet surface excitation (MUSE) using high-index immersion illumination
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement..
Microscopy with ultraviolet surface excitation (MUSE) typically has an optical sectioning thickness significantly larger than standard physical sectioning thickness, resulting in increased background fluorescence and higher feature density compared to formalin-fixed, paraffin-embedded physical sections. We demonstrate that high-index immersion with angled illumination significantly reduces optical sectioning thickness through increased angle of refraction of excitation light at the tissue interface. We present a novel objective dipping cap and waveguide-based MUSE illuminator design with high-index immersion and quantify the improvement in optical sectioning thickness, demonstrating an e-1 section thickness reduction to 6.67 µm in tissue. Simultaneously, the waveguide illuminator can be combined with high or low magnification objectives, and we demonstrate a 6 mm2 field of view, wider than a conventional 10x pathology objective. Finally, we show that resolution and contrast can be further improved using deconvolution and focal stacking, enabling imaging that is robust to irregular surface profiles on surgical specimens.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:12 |
---|---|
Enthalten in: |
Biomedical optics express - 12(2021), 10 vom: 01. Okt., Seite 6461-6473 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ching-Roa, Vincent D [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 02.02.2022 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1364/BOE.435520 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM332837912 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM332837912 | ||
003 | DE-627 | ||
005 | 20231225220412.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1364/BOE.435520 |2 doi | |
028 | 5 | 2 | |a pubmed24n1109.xml |
035 | |a (DE-627)NLM332837912 | ||
035 | |a (NLM)34745749 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ching-Roa, Vincent D |e verfasserin |4 aut | |
245 | 1 | 0 | |a Improved microscopy with ultraviolet surface excitation (MUSE) using high-index immersion illumination |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 02.02.2022 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement. | ||
520 | |a Microscopy with ultraviolet surface excitation (MUSE) typically has an optical sectioning thickness significantly larger than standard physical sectioning thickness, resulting in increased background fluorescence and higher feature density compared to formalin-fixed, paraffin-embedded physical sections. We demonstrate that high-index immersion with angled illumination significantly reduces optical sectioning thickness through increased angle of refraction of excitation light at the tissue interface. We present a novel objective dipping cap and waveguide-based MUSE illuminator design with high-index immersion and quantify the improvement in optical sectioning thickness, demonstrating an e-1 section thickness reduction to 6.67 µm in tissue. Simultaneously, the waveguide illuminator can be combined with high or low magnification objectives, and we demonstrate a 6 mm2 field of view, wider than a conventional 10x pathology objective. Finally, we show that resolution and contrast can be further improved using deconvolution and focal stacking, enabling imaging that is robust to irregular surface profiles on surgical specimens | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Huang, Chi Z |e verfasserin |4 aut | |
700 | 1 | |a Giacomelli, Michael G |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Biomedical optics express |d 2010 |g 12(2021), 10 vom: 01. Okt., Seite 6461-6473 |w (DE-627)NLM203936965 |x 2156-7085 |7 nnns |
773 | 1 | 8 | |g volume:12 |g year:2021 |g number:10 |g day:01 |g month:10 |g pages:6461-6473 |
856 | 4 | 0 | |u http://dx.doi.org/10.1364/BOE.435520 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 12 |j 2021 |e 10 |b 01 |c 10 |h 6461-6473 |