Step-to-Step Kinematic Validation between an Inertial Measurement Unit (IMU) 3D System, a Combined Laser+IMU System and Force Plates during a 50 M Sprint in a Cohort of Sprinters
The purpose was to compare step-by-step kinematics measured using force plates (criterion), an IMU only and a combined laser IMU system in well-trained sprinters. Fourteen male experienced sprinters performed a 50-m sprint. Step-by-step kinematics were measured by 50 force plates and compared with an IMU-3D motion capture system and a combined laser+IMU system attached to each foot. Results showed that step kinematics (step velocity, length, contact and flight times) were different when measured with the IMU-3D system, compared with force plates, while the laser+IMU system, showed in general the same kinematics as measured with force plates without a systematic bias. Based upon the findings it can be concluded that the laser+IMU system is as accurate in measuring step-by-step kinematics as the force plate system. At the moment, the IMU-3D system is only accurate in measuring stride patterns (temporal parameters); it is not accurate enough to measure step lengths (spatial) and velocities due to the inaccuracies in step length, especially at high velocities. It is suggested that this laser+IMU system is valid and accurate, which can be used easily in training and competition to obtain step-by step kinematics and give direct feedback of this information during training and competition.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:21 |
---|---|
Enthalten in: |
Sensors (Basel, Switzerland) - 21(2021), 19 vom: 30. Sept. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
van den Tillaar, Roland [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 14.10.2021 Date Revised 16.10.2021 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.3390/s21196560 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM331816881 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM331816881 | ||
003 | DE-627 | ||
005 | 20231225214313.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/s21196560 |2 doi | |
028 | 5 | 2 | |a pubmed24n1106.xml |
035 | |a (DE-627)NLM331816881 | ||
035 | |a (NLM)34640882 | ||
035 | |a (PII)6560 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a van den Tillaar, Roland |e verfasserin |4 aut | |
245 | 1 | 0 | |a Step-to-Step Kinematic Validation between an Inertial Measurement Unit (IMU) 3D System, a Combined Laser+IMU System and Force Plates during a 50 M Sprint in a Cohort of Sprinters |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 14.10.2021 | ||
500 | |a Date Revised 16.10.2021 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The purpose was to compare step-by-step kinematics measured using force plates (criterion), an IMU only and a combined laser IMU system in well-trained sprinters. Fourteen male experienced sprinters performed a 50-m sprint. Step-by-step kinematics were measured by 50 force plates and compared with an IMU-3D motion capture system and a combined laser+IMU system attached to each foot. Results showed that step kinematics (step velocity, length, contact and flight times) were different when measured with the IMU-3D system, compared with force plates, while the laser+IMU system, showed in general the same kinematics as measured with force plates without a systematic bias. Based upon the findings it can be concluded that the laser+IMU system is as accurate in measuring step-by-step kinematics as the force plate system. At the moment, the IMU-3D system is only accurate in measuring stride patterns (temporal parameters); it is not accurate enough to measure step lengths (spatial) and velocities due to the inaccuracies in step length, especially at high velocities. It is suggested that this laser+IMU system is valid and accurate, which can be used easily in training and competition to obtain step-by step kinematics and give direct feedback of this information during training and competition | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a force plates | |
650 | 4 | |a inertial sensors | |
650 | 4 | |a musclelab | |
650 | 4 | |a xsens | |
700 | 1 | |a Nagahara, Ryu |e verfasserin |4 aut | |
700 | 1 | |a Gleadhill, Sam |e verfasserin |4 aut | |
700 | 1 | |a Jiménez-Reyes, Pedro |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Sensors (Basel, Switzerland) |d 2007 |g 21(2021), 19 vom: 30. Sept. |w (DE-627)NLM187985170 |x 1424-8220 |7 nnns |
773 | 1 | 8 | |g volume:21 |g year:2021 |g number:19 |g day:30 |g month:09 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/s21196560 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 21 |j 2021 |e 19 |b 30 |c 09 |