Improving D-2-hydroxyglutarate MR spectroscopic imaging in mutant isocitrate dehydrogenase glioma patients with multiplexed RF-receive/B0 -shim array coils at 3 T
© 2021 John Wiley & Sons, Ltd..
MR spectroscopic imaging (MRSI) noninvasively maps the metabolism of human brains. In particular, the imaging of D-2-hydroxyglutarate (2HG) produced by glioma isocitrate dehydrogenase (IDH) mutations has become a key application in neuro-oncology. However, the performance of full field-of-view MRSI is limited by B0 spatial nonuniformity and lipid artifacts from tissues surrounding the brain. Array coils that multiplex RF-receive and B0 -shim electrical currents (AC/DC mixing) over the same conductive loops provide many degrees of freedom to improve B0 uniformity and reduce lipid artifacts. AC/DC coils are highly efficient due to compact design, requiring low shim currents (<2 A) that can be switched fast (0.5 ms) with high interscan reproducibility (10% coefficient of variation for repeat measurements). We measured four tumor patients and five volunteers at 3 T and show that using AC/DC coils in addition to the vendor-provided second-order spherical harmonics shim provides 19% narrower spectral linewidth, 6% higher SNR, and 23% less lipid content for unrestricted field-of-view MRSI, compared with the vendor-provided shim alone. We demonstrate that improvement in MRSI data quality led to 2HG maps with higher contrast-to-noise ratio for tumors that coincide better with the FLAIR-enhancing lesions in mutant IDH glioma patients. Smaller Cramér-Rao lower bounds for 2HG quantification are obtained in tumors by AC/DC shim, corroborating with simulations that predicted improved accuracy and precision for narrower linewidths. AC/DC coils can be used synergistically with optimized acquisition schemes to improve metabolic imaging for precision oncology of glioma patients. Furthermore, this methodology has broad applicability to other neurological disorders and neuroscience.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:35 |
---|---|
Enthalten in: |
NMR in biomedicine - 35(2022), 1 vom: 01. Jan., Seite e4621 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Strasser, Bernhard [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 28.03.2022 Date Revised 15.11.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1002/nbm.4621 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM331502801 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM331502801 | ||
003 | DE-627 | ||
005 | 20231225213615.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/nbm.4621 |2 doi | |
028 | 5 | 2 | |a pubmed24n1104.xml |
035 | |a (DE-627)NLM331502801 | ||
035 | |a (NLM)34609036 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Strasser, Bernhard |e verfasserin |4 aut | |
245 | 1 | 0 | |a Improving D-2-hydroxyglutarate MR spectroscopic imaging in mutant isocitrate dehydrogenase glioma patients with multiplexed RF-receive/B0 -shim array coils at 3 T |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 28.03.2022 | ||
500 | |a Date Revised 15.11.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021 John Wiley & Sons, Ltd. | ||
520 | |a MR spectroscopic imaging (MRSI) noninvasively maps the metabolism of human brains. In particular, the imaging of D-2-hydroxyglutarate (2HG) produced by glioma isocitrate dehydrogenase (IDH) mutations has become a key application in neuro-oncology. However, the performance of full field-of-view MRSI is limited by B0 spatial nonuniformity and lipid artifacts from tissues surrounding the brain. Array coils that multiplex RF-receive and B0 -shim electrical currents (AC/DC mixing) over the same conductive loops provide many degrees of freedom to improve B0 uniformity and reduce lipid artifacts. AC/DC coils are highly efficient due to compact design, requiring low shim currents (<2 A) that can be switched fast (0.5 ms) with high interscan reproducibility (10% coefficient of variation for repeat measurements). We measured four tumor patients and five volunteers at 3 T and show that using AC/DC coils in addition to the vendor-provided second-order spherical harmonics shim provides 19% narrower spectral linewidth, 6% higher SNR, and 23% less lipid content for unrestricted field-of-view MRSI, compared with the vendor-provided shim alone. We demonstrate that improvement in MRSI data quality led to 2HG maps with higher contrast-to-noise ratio for tumors that coincide better with the FLAIR-enhancing lesions in mutant IDH glioma patients. Smaller Cramér-Rao lower bounds for 2HG quantification are obtained in tumors by AC/DC shim, corroborating with simulations that predicted improved accuracy and precision for narrower linewidths. AC/DC coils can be used synergistically with optimized acquisition schemes to improve metabolic imaging for precision oncology of glioma patients. Furthermore, this methodology has broad applicability to other neurological disorders and neuroscience | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a D-2-hydroxyglutarate | |
650 | 4 | |a glioma brain tumor | |
650 | 4 | |a isocitrate dehydrogenase mutations | |
650 | 4 | |a magnetic resonance spectroscopic imaging | |
650 | 4 | |a multicoil shimming | |
650 | 4 | |a multiplexed RF-receive and B0-shim array | |
650 | 4 | |a precision oncology | |
650 | 7 | |a Glutarates |2 NLM | |
650 | 7 | |a alpha-hydroxyglutarate |2 NLM | |
650 | 7 | |a 2889-31-8 |2 NLM | |
650 | 7 | |a Isocitrate Dehydrogenase |2 NLM | |
650 | 7 | |a EC 1.1.1.41 |2 NLM | |
700 | 1 | |a Arango, Nicolas S |e verfasserin |4 aut | |
700 | 1 | |a Stockmann, Jason P |e verfasserin |4 aut | |
700 | 1 | |a Gagoski, Borjan |e verfasserin |4 aut | |
700 | 1 | |a Thapa, Bijaya |e verfasserin |4 aut | |
700 | 1 | |a Li, Xianqi |e verfasserin |4 aut | |
700 | 1 | |a Bogner, Wolfgang |e verfasserin |4 aut | |
700 | 1 | |a Moser, Philipp |e verfasserin |4 aut | |
700 | 1 | |a Small, Julia |e verfasserin |4 aut | |
700 | 1 | |a Cahill, Daniel P |e verfasserin |4 aut | |
700 | 1 | |a Batchelor, Tracy T |e verfasserin |4 aut | |
700 | 1 | |a Dietrich, Jorg |e verfasserin |4 aut | |
700 | 1 | |a van der Kouwe, Andre |e verfasserin |4 aut | |
700 | 1 | |a White, Jacob |e verfasserin |4 aut | |
700 | 1 | |a Adalsteinsson, Elfar |e verfasserin |4 aut | |
700 | 1 | |a Andronesi, Ovidiu C |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t NMR in biomedicine |d 1996 |g 35(2022), 1 vom: 01. Jan., Seite e4621 |w (DE-627)NLM013015540 |x 1099-1492 |7 nnns |
773 | 1 | 8 | |g volume:35 |g year:2022 |g number:1 |g day:01 |g month:01 |g pages:e4621 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/nbm.4621 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 35 |j 2022 |e 1 |b 01 |c 01 |h e4621 |