Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage
© 2021. The Author(s)..
Radiological examination of the brain is a critical determinant of stroke care pathways. Accessible neuroimaging is essential to detect the presence of intracerebral hemorrhage (ICH). Conventional magnetic resonance imaging (MRI) operates at high magnetic field strength (1.5-3 T), which requires an access-controlled environment, rendering MRI often inaccessible. We demonstrate the use of a low-field MRI (0.064 T) for ICH evaluation. Patients were imaged using conventional neuroimaging (non-contrast computerized tomography (CT) or 1.5/3 T MRI) and portable MRI (pMRI) at Yale New Haven Hospital from July 2018 to November 2020. Two board-certified neuroradiologists evaluated a total of 144 pMRI examinations (56 ICH, 48 acute ischemic stroke, 40 healthy controls) and one ICH imaging core lab researcher reviewed the cases of disagreement. Raters correctly detected ICH in 45 of 56 cases (80.4% sensitivity, 95%CI: [0.68-0.90]). Blood-negative cases were correctly identified in 85 of 88 cases (96.6% specificity, 95%CI: [0.90-0.99]). Manually segmented hematoma volumes and ABC/2 estimated volumes on pMRI correlate with conventional imaging volumes (ICC = 0.955, p = 1.69e-30 and ICC = 0.875, p = 1.66e-8, respectively). Hematoma volumes measured on pMRI correlate with NIH stroke scale (NIHSS) and clinical outcome (mRS) at discharge for manual and ABC/2 volumes. Low-field pMRI may be useful in bringing advanced MRI technology to resource-limited settings.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:12 |
---|---|
Enthalten in: |
Nature communications - 12(2021), 1 vom: 25. Aug., Seite 5119 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Mazurek, Mercy H [VerfasserIn] |
---|
Links: |
---|
Themen: |
Journal Article |
---|
Anmerkungen: |
Date Completed 24.09.2021 Date Revised 05.02.2023 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.1038/s41467-021-25441-6 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM329769715 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM329769715 | ||
003 | DE-627 | ||
005 | 20231225205837.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1038/s41467-021-25441-6 |2 doi | |
028 | 5 | 2 | |a pubmed24n1099.xml |
035 | |a (DE-627)NLM329769715 | ||
035 | |a (NLM)34433813 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Mazurek, Mercy H |e verfasserin |4 aut | |
245 | 1 | 0 | |a Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 24.09.2021 | ||
500 | |a Date Revised 05.02.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021. The Author(s). | ||
520 | |a Radiological examination of the brain is a critical determinant of stroke care pathways. Accessible neuroimaging is essential to detect the presence of intracerebral hemorrhage (ICH). Conventional magnetic resonance imaging (MRI) operates at high magnetic field strength (1.5-3 T), which requires an access-controlled environment, rendering MRI often inaccessible. We demonstrate the use of a low-field MRI (0.064 T) for ICH evaluation. Patients were imaged using conventional neuroimaging (non-contrast computerized tomography (CT) or 1.5/3 T MRI) and portable MRI (pMRI) at Yale New Haven Hospital from July 2018 to November 2020. Two board-certified neuroradiologists evaluated a total of 144 pMRI examinations (56 ICH, 48 acute ischemic stroke, 40 healthy controls) and one ICH imaging core lab researcher reviewed the cases of disagreement. Raters correctly detected ICH in 45 of 56 cases (80.4% sensitivity, 95%CI: [0.68-0.90]). Blood-negative cases were correctly identified in 85 of 88 cases (96.6% specificity, 95%CI: [0.90-0.99]). Manually segmented hematoma volumes and ABC/2 estimated volumes on pMRI correlate with conventional imaging volumes (ICC = 0.955, p = 1.69e-30 and ICC = 0.875, p = 1.66e-8, respectively). Hematoma volumes measured on pMRI correlate with NIH stroke scale (NIHSS) and clinical outcome (mRS) at discharge for manual and ABC/2 volumes. Low-field pMRI may be useful in bringing advanced MRI technology to resource-limited settings | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Observational Study | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Cahn, Bradley A |e verfasserin |4 aut | |
700 | 1 | |a Yuen, Matthew M |e verfasserin |4 aut | |
700 | 1 | |a Prabhat, Anjali M |e verfasserin |4 aut | |
700 | 1 | |a Chavva, Isha R |e verfasserin |4 aut | |
700 | 1 | |a Shah, Jill T |e verfasserin |4 aut | |
700 | 1 | |a Crawford, Anna L |e verfasserin |4 aut | |
700 | 1 | |a Welch, E Brian |e verfasserin |4 aut | |
700 | 1 | |a Rothberg, Jonathan |e verfasserin |4 aut | |
700 | 1 | |a Sacolick, Laura |e verfasserin |4 aut | |
700 | 1 | |a Poole, Michael |e verfasserin |4 aut | |
700 | 1 | |a Wira, Charles |e verfasserin |4 aut | |
700 | 1 | |a Matouk, Charles C |e verfasserin |4 aut | |
700 | 1 | |a Ward, Adrienne |e verfasserin |4 aut | |
700 | 1 | |a Timario, Nona |e verfasserin |4 aut | |
700 | 1 | |a Leasure, Audrey |e verfasserin |4 aut | |
700 | 1 | |a Beekman, Rachel |e verfasserin |4 aut | |
700 | 1 | |a Peng, Teng J |e verfasserin |4 aut | |
700 | 1 | |a Witsch, Jens |e verfasserin |4 aut | |
700 | 1 | |a Antonios, Joseph P |e verfasserin |4 aut | |
700 | 1 | |a Falcone, Guido J |e verfasserin |4 aut | |
700 | 1 | |a Gobeske, Kevin T |e verfasserin |4 aut | |
700 | 1 | |a Petersen, Nils |e verfasserin |4 aut | |
700 | 1 | |a Schindler, Joseph |e verfasserin |4 aut | |
700 | 1 | |a Sansing, Lauren |e verfasserin |4 aut | |
700 | 1 | |a Gilmore, Emily J |e verfasserin |4 aut | |
700 | 1 | |a Hwang, David Y |e verfasserin |4 aut | |
700 | 1 | |a Kim, Jennifer A |e verfasserin |4 aut | |
700 | 1 | |a Malhotra, Ajay |e verfasserin |4 aut | |
700 | 1 | |a Sze, Gordon |e verfasserin |4 aut | |
700 | 1 | |a Rosen, Matthew S |e verfasserin |4 aut | |
700 | 1 | |a Kimberly, W Taylor |e verfasserin |4 aut | |
700 | 1 | |a Sheth, Kevin N |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Nature communications |d 2010 |g 12(2021), 1 vom: 25. Aug., Seite 5119 |w (DE-627)NLM199274525 |x 2041-1723 |7 nnns |
773 | 1 | 8 | |g volume:12 |g year:2021 |g number:1 |g day:25 |g month:08 |g pages:5119 |
856 | 4 | 0 | |u http://dx.doi.org/10.1038/s41467-021-25441-6 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 12 |j 2021 |e 1 |b 25 |c 08 |h 5119 |