Effect of computer-assisted design and manufacturing cutting and drilling guides accompanied with pre-bent titanium plates on the correction of skeletal class II malocclusion : a randomized controlled trial
Copyright © 2021. Published by Elsevier Inc..
This study was performed to assess the effect of correcting skeletal class II malocclusion based on the application of computer-assisted design and manufacturing (CAD/CAM) cutting and drilling guides accompanied with pre-bent titanium plates. Fifty patients with skeletal class II malocclusion were recruited into this prospective randomized controlled clinical trial and assigned to two groups. Patients underwent bilateral sagittal split ramus osteotomy directed by CAD/CAM cutting and drilling guides accompanied with pre-bent titanium plates (group A) or CAD/CAM splints (group B). Postoperative assessments were performed. Differences between the virtually simulated and postoperative models were measured. Patients in both groups had a satisfactory occlusion and appearance. More accurate repositioning of the proximal segment was found in group A than in group B when comparing linear and angular differences to reference planes; however, no significant difference was revealed for the distal segment. In conclusion, CAD/CAM cutting and drilling guides with pre-bent titanium plates can provide considerable surgical accuracy for the positional control of the proximal segments in bilateral sagittal split ramus osteotomy for the correction of skeletal class II deformities.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:50 |
---|---|
Enthalten in: |
International journal of oral and maxillofacial surgery - 50(2021), 10 vom: 05. Okt., Seite 1320-1328 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Liu, S [VerfasserIn] |
---|
Links: |
---|
Themen: |
Computer-aided design |
---|
Anmerkungen: |
Date Completed 27.09.2021 Date Revised 27.09.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.ijom.2021.01.023 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM322429277 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM322429277 | ||
003 | DE-627 | ||
005 | 20231225182024.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.ijom.2021.01.023 |2 doi | |
028 | 5 | 2 | |a pubmed24n1074.xml |
035 | |a (DE-627)NLM322429277 | ||
035 | |a (NLM)33685740 | ||
035 | |a (PII)S0901-5027(21)00087-4 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Liu, S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Effect of computer-assisted design and manufacturing cutting and drilling guides accompanied with pre-bent titanium plates on the correction of skeletal class II malocclusion |b a randomized controlled trial |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 27.09.2021 | ||
500 | |a Date Revised 27.09.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2021. Published by Elsevier Inc. | ||
520 | |a This study was performed to assess the effect of correcting skeletal class II malocclusion based on the application of computer-assisted design and manufacturing (CAD/CAM) cutting and drilling guides accompanied with pre-bent titanium plates. Fifty patients with skeletal class II malocclusion were recruited into this prospective randomized controlled clinical trial and assigned to two groups. Patients underwent bilateral sagittal split ramus osteotomy directed by CAD/CAM cutting and drilling guides accompanied with pre-bent titanium plates (group A) or CAD/CAM splints (group B). Postoperative assessments were performed. Differences between the virtually simulated and postoperative models were measured. Patients in both groups had a satisfactory occlusion and appearance. More accurate repositioning of the proximal segment was found in group A than in group B when comparing linear and angular differences to reference planes; however, no significant difference was revealed for the distal segment. In conclusion, CAD/CAM cutting and drilling guides with pre-bent titanium plates can provide considerable surgical accuracy for the positional control of the proximal segments in bilateral sagittal split ramus osteotomy for the correction of skeletal class II deformities | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Randomized Controlled Trial | |
650 | 4 | |a computer-aided design | |
650 | 4 | |a malocclusion | |
650 | 4 | |a mandibular condyle | |
650 | 4 | |a orthognathic surgery | |
650 | 4 | |a three-dimensional printing | |
650 | 7 | |a Titanium |2 NLM | |
650 | 7 | |a D1JT611TNE |2 NLM | |
700 | 1 | |a Li, J |e verfasserin |4 aut | |
700 | 1 | |a Xu, C |e verfasserin |4 aut | |
700 | 1 | |a Zhou, H |e verfasserin |4 aut | |
700 | 1 | |a Liao, C |e verfasserin |4 aut | |
700 | 1 | |a Fei, W |e verfasserin |4 aut | |
700 | 1 | |a Luo, E |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t International journal of oral and maxillofacial surgery |d 1995 |g 50(2021), 10 vom: 05. Okt., Seite 1320-1328 |w (DE-627)NLM012633488 |x 1399-0020 |7 nnns |
773 | 1 | 8 | |g volume:50 |g year:2021 |g number:10 |g day:05 |g month:10 |g pages:1320-1328 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ijom.2021.01.023 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 50 |j 2021 |e 10 |b 05 |c 10 |h 1320-1328 |