Radiation doses from head, neck, chest and abdominal CT examinations : an institutional dose report
PURPOSE: We aimed to obtain typical values for head, neck, chest, and abdominal computed tomography (CT) examinations from routine patients in 2018, and to review our data with national and international diagnostic reference levels (DRLs).
METHODS: Single-phase head, neck, chest, and abdominal CT scans of adults performed in 64-slice CT in 2018 were included in this study. Radiation dose parameters of CT scans were obtained from the picture archiving and communication system of our hospital. Volumetric CT dose index (CTDIvol) and dose length product (DLP) values were recorded. Effective dose (ED) and scan length was calculated. A 16 cm diameter phantom is referenced for head CT, and 32 cm diameter phantom is referenced for neck, chest, and abdominal CT. Descriptive statistics of the variables were given according to the normality testing.
RESULTS: Median CTDIvol value was 53 mGy for the head, 13.1 mGy for the neck, 8.3 mGy for the chest, and 8.6 mGy for the abdomen. Median DLP value was 988 mGy.cm for the head, 299 mGy.cm for the neck, 314 mGy.cm for the chest, and 457 mGy.cm for the abdomen. Median ED value was 2.07 mSv for the head, 1.76 mSv for the neck, 4.4 mSv for the chest, and 6.8 mSv for the abdomen. Considering national DRLs, median CTDIvol values of head, chest, and abdomen were lower, whereas median DLP and ED values of head and chest were higher. For the abdomen, the median DLP and ED values were lower.
CONCLUSION: Overall radiation dose parameters obtained in this study points out the need for optimization of head CT examinations in our institution.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:27 |
---|---|
Enthalten in: |
Diagnostic and interventional radiology (Ankara, Turkey) - 27(2021), 1 vom: 21. Jan., Seite 147-151 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Atlı, Eray [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 30.08.2021 Date Revised 10.11.2023 published: Print Citation Status MEDLINE |
---|
doi: |
10.5152/dir.2020.19560 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM320378349 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM320378349 | ||
003 | DE-627 | ||
005 | 20231225173438.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.5152/dir.2020.19560 |2 doi | |
028 | 5 | 2 | |a pubmed24n1067.xml |
035 | |a (DE-627)NLM320378349 | ||
035 | |a (NLM)33475510 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Atlı, Eray |e verfasserin |4 aut | |
245 | 1 | 0 | |a Radiation doses from head, neck, chest and abdominal CT examinations |b an institutional dose report |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 30.08.2021 | ||
500 | |a Date Revised 10.11.2023 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a PURPOSE: We aimed to obtain typical values for head, neck, chest, and abdominal computed tomography (CT) examinations from routine patients in 2018, and to review our data with national and international diagnostic reference levels (DRLs) | ||
520 | |a METHODS: Single-phase head, neck, chest, and abdominal CT scans of adults performed in 64-slice CT in 2018 were included in this study. Radiation dose parameters of CT scans were obtained from the picture archiving and communication system of our hospital. Volumetric CT dose index (CTDIvol) and dose length product (DLP) values were recorded. Effective dose (ED) and scan length was calculated. A 16 cm diameter phantom is referenced for head CT, and 32 cm diameter phantom is referenced for neck, chest, and abdominal CT. Descriptive statistics of the variables were given according to the normality testing | ||
520 | |a RESULTS: Median CTDIvol value was 53 mGy for the head, 13.1 mGy for the neck, 8.3 mGy for the chest, and 8.6 mGy for the abdomen. Median DLP value was 988 mGy.cm for the head, 299 mGy.cm for the neck, 314 mGy.cm for the chest, and 457 mGy.cm for the abdomen. Median ED value was 2.07 mSv for the head, 1.76 mSv for the neck, 4.4 mSv for the chest, and 6.8 mSv for the abdomen. Considering national DRLs, median CTDIvol values of head, chest, and abdomen were lower, whereas median DLP and ED values of head and chest were higher. For the abdomen, the median DLP and ED values were lower | ||
520 | |a CONCLUSION: Overall radiation dose parameters obtained in this study points out the need for optimization of head CT examinations in our institution | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Uyanık, Sadık Ahmet |e verfasserin |4 aut | |
700 | 1 | |a Öğüşlü, Umut |e verfasserin |4 aut | |
700 | 1 | |a Çevik Cenkeri, Halime |e verfasserin |4 aut | |
700 | 1 | |a Yılmaz, Birnur |e verfasserin |4 aut | |
700 | 1 | |a Gümüş, Burçak |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diagnostic and interventional radiology (Ankara, Turkey) |d 2005 |g 27(2021), 1 vom: 21. Jan., Seite 147-151 |w (DE-627)NLM154477109 |x 1305-3612 |7 nnns |
773 | 1 | 8 | |g volume:27 |g year:2021 |g number:1 |g day:21 |g month:01 |g pages:147-151 |
856 | 4 | 0 | |u http://dx.doi.org/10.5152/dir.2020.19560 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 27 |j 2021 |e 1 |b 21 |c 01 |h 147-151 |