USE OF CLINICAL EXPOSURE INDEX AND DEVIATION INDEX BASED ON NATIONAL DIAGNOSTIC REFERENCE LEVEL AS DOSE-OPTIMIZATION TOOLS FOR GENERAL RADIOGRAPHY IN KOREA
© The Author(s) 2020. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissionsoup.com..
The International Electrotechnical Commission introduced the concepts of exposure index (EI), target exposure index (EIT) and deviation index (DI) to manage and optimize patient dose in real time. In this study, we have proposed an appropriate method for setting the EIT based on the Korean national diagnostic reference levels (DRLs). Furthermore, we evaluated the use of clinical EI, EIT and DI as tools for patient dose optimization in clinical environments by observing the changes in DI with those in EIT. According to the Korean national exposure conditions, we conducted experiments on three representative radiographic examinations (chest posterior-anterior, lateral and abdomen anterior-posterior) of clinical environments. As the exposure conditions and DRLs varied, the clinical EI, EIT and DI also varied. These results reveal that the clinical EI, EIT and DI can be used as tools for optimizing the patient dose if EIT is periodically and properly updated.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - year:2020 |
---|---|
Enthalten in: |
Radiation protection dosimetry - (2020) vom: 17. Nov. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Park, Hyemin [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 22.02.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.1093/rpd/ncaa185 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM31768535X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM31768535X | ||
003 | DE-627 | ||
005 | 20240229142954.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1093/rpd/ncaa185 |2 doi | |
028 | 5 | 2 | |a pubmed24n1303.xml |
035 | |a (DE-627)NLM31768535X | ||
035 | |a (NLM)33201240 | ||
035 | |a (PII)ncaa185 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Park, Hyemin |e verfasserin |4 aut | |
245 | 1 | 0 | |a USE OF CLINICAL EXPOSURE INDEX AND DEVIATION INDEX BASED ON NATIONAL DIAGNOSTIC REFERENCE LEVEL AS DOSE-OPTIMIZATION TOOLS FOR GENERAL RADIOGRAPHY IN KOREA |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 22.02.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a © The Author(s) 2020. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissionsoup.com. | ||
520 | |a The International Electrotechnical Commission introduced the concepts of exposure index (EI), target exposure index (EIT) and deviation index (DI) to manage and optimize patient dose in real time. In this study, we have proposed an appropriate method for setting the EIT based on the Korean national diagnostic reference levels (DRLs). Furthermore, we evaluated the use of clinical EI, EIT and DI as tools for patient dose optimization in clinical environments by observing the changes in DI with those in EIT. According to the Korean national exposure conditions, we conducted experiments on three representative radiographic examinations (chest posterior-anterior, lateral and abdomen anterior-posterior) of clinical environments. As the exposure conditions and DRLs varied, the clinical EI, EIT and DI also varied. These results reveal that the clinical EI, EIT and DI can be used as tools for optimizing the patient dose if EIT is periodically and properly updated | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Yoon, Yongsu |e verfasserin |4 aut | |
700 | 1 | |a Kim, Jungmin |e verfasserin |4 aut | |
700 | 1 | |a Kim, Jungsu |e verfasserin |4 aut | |
700 | 1 | |a Jeong, Hoiwoun |e verfasserin |4 aut | |
700 | 1 | |a Tanaka, Nobukazu |e verfasserin |4 aut | |
700 | 1 | |a Morishita, Junji |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Radiation protection dosimetry |d 1987 |g (2020) vom: 17. Nov. |w (DE-627)NLM080850561 |x 1742-3406 |7 nnns |
773 | 1 | 8 | |g year:2020 |g day:17 |g month:11 |
856 | 4 | 0 | |u http://dx.doi.org/10.1093/rpd/ncaa185 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2020 |b 17 |c 11 |