Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis
Importance: The outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic valve stenosis have not been studied in a large scale, multicentered, prospective fashion.
Objective: To evaluate the procedural safety, efficacy, and 30-day outcomes of TAVR in patients with bicuspid aortic stenosis at low surgical risk.
Design, Setting, and Participants: The Low Risk Bicuspid Study is a prospective, single-arm trial study with inclusion/exclusion criteria developed from the Evolut Low Risk Randomized Trial. Follow-up is planned for 10 years. Patients underwent TAVR at 25 centers in the United States who were also participating in the Evolut Low Risk Randomized Trial from December 2018 to October 2019. Eligible patients had severe bicuspid aortic valve stenosis and met American Heart Association/American College of Cardiology guideline indications for aortic valve replacement.
Interventions: Patients underwent attempted implant of an Evolut or Evolut PRO transcatheter aortic valve, with valve size based on annular measurements.
Main Outcomes and Measures: The prespecified primary end point was the incidence of all-cause mortality or disabling stroke at 30 days. The prespecified primary efficacy end point was device success defined as the absence of procedural mortality, the correct position of 1 bioprosthetic heart valve in the proper anatomical location, and the absence of more than mild aortic regurgitation postprocedure.
Results: A total of 150 patients underwent an attempted implant. Baseline characteristics include mean age of 70.3 (5.5) years, 48.0% female (n = 72), and a mean Society of Thoracic Surgeons score of 1.4 (0.6%). Most patients (136; 90.7%) had Sievers type I valve morphology. The incidence of all-cause mortality or disabling stroke was 1.3% (95% CI, 0.3%-5.3%) at 30 days. The device success rate was 95.3% (95% CI, 90.5%-98.1%). At 30 days, the mean (SD) AV gradient was 7.6 (3.7) mm Hg and effective orifice area was 2.3 (0.7) cm2. A new permanent pacemaker was implanted in 22 patients (15.1%). No patients had greater than mild paravalvular leak.
Conclusions and Relevance: Transcatheter aortic valve replacement in low-surgical risk patients with bicuspid aortic valve stenosis achieved favorable 30-day results, with low rates of death and stroke and high device success rate.
Trial Registration: ClinicalTrials.gov Identifier: NCT03635424.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:6 |
---|---|
Enthalten in: |
JAMA cardiology - 6(2021), 1 vom: 01. Jan., Seite 50-57 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Forrest, John K [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 12.01.2022 Date Revised 12.01.2022 published: Print ClinicalTrials.gov: NCT03635424 Citation Status MEDLINE |
---|
doi: |
10.1001/jamacardio.2020.4738 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM316015482 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM316015482 | ||
003 | DE-627 | ||
005 | 20231225160149.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1001/jamacardio.2020.4738 |2 doi | |
028 | 5 | 2 | |a pubmed24n1053.xml |
035 | |a (DE-627)NLM316015482 | ||
035 | |a (NLM)33031491 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Forrest, John K |e verfasserin |4 aut | |
245 | 1 | 0 | |a Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 12.01.2022 | ||
500 | |a Date Revised 12.01.2022 | ||
500 | |a published: Print | ||
500 | |a ClinicalTrials.gov: NCT03635424 | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Importance: The outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic valve stenosis have not been studied in a large scale, multicentered, prospective fashion | ||
520 | |a Objective: To evaluate the procedural safety, efficacy, and 30-day outcomes of TAVR in patients with bicuspid aortic stenosis at low surgical risk | ||
520 | |a Design, Setting, and Participants: The Low Risk Bicuspid Study is a prospective, single-arm trial study with inclusion/exclusion criteria developed from the Evolut Low Risk Randomized Trial. Follow-up is planned for 10 years. Patients underwent TAVR at 25 centers in the United States who were also participating in the Evolut Low Risk Randomized Trial from December 2018 to October 2019. Eligible patients had severe bicuspid aortic valve stenosis and met American Heart Association/American College of Cardiology guideline indications for aortic valve replacement | ||
520 | |a Interventions: Patients underwent attempted implant of an Evolut or Evolut PRO transcatheter aortic valve, with valve size based on annular measurements | ||
520 | |a Main Outcomes and Measures: The prespecified primary end point was the incidence of all-cause mortality or disabling stroke at 30 days. The prespecified primary efficacy end point was device success defined as the absence of procedural mortality, the correct position of 1 bioprosthetic heart valve in the proper anatomical location, and the absence of more than mild aortic regurgitation postprocedure | ||
520 | |a Results: A total of 150 patients underwent an attempted implant. Baseline characteristics include mean age of 70.3 (5.5) years, 48.0% female (n = 72), and a mean Society of Thoracic Surgeons score of 1.4 (0.6%). Most patients (136; 90.7%) had Sievers type I valve morphology. The incidence of all-cause mortality or disabling stroke was 1.3% (95% CI, 0.3%-5.3%) at 30 days. The device success rate was 95.3% (95% CI, 90.5%-98.1%). At 30 days, the mean (SD) AV gradient was 7.6 (3.7) mm Hg and effective orifice area was 2.3 (0.7) cm2. A new permanent pacemaker was implanted in 22 patients (15.1%). No patients had greater than mild paravalvular leak | ||
520 | |a Conclusions and Relevance: Transcatheter aortic valve replacement in low-surgical risk patients with bicuspid aortic valve stenosis achieved favorable 30-day results, with low rates of death and stroke and high device success rate | ||
520 | |a Trial Registration: ClinicalTrials.gov Identifier: NCT03635424 | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Ramlawi, Basel |e verfasserin |4 aut | |
700 | 1 | |a Deeb, G Michael |e verfasserin |4 aut | |
700 | 1 | |a Zahr, Firas |e verfasserin |4 aut | |
700 | 1 | |a Song, Howard K |e verfasserin |4 aut | |
700 | 1 | |a Kleiman, Neal S |e verfasserin |4 aut | |
700 | 1 | |a Chetcuti, Stanley J |e verfasserin |4 aut | |
700 | 1 | |a Michelena, Hector I |e verfasserin |4 aut | |
700 | 1 | |a Mangi, Abeel A |e verfasserin |4 aut | |
700 | 1 | |a Skiles, Jeffrey A |e verfasserin |4 aut | |
700 | 1 | |a Huang, Jian |e verfasserin |4 aut | |
700 | 1 | |a Popma, Jeffrey J |e verfasserin |4 aut | |
700 | 1 | |a Reardon, Michael J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t JAMA cardiology |d 2016 |g 6(2021), 1 vom: 01. Jan., Seite 50-57 |w (DE-627)NLM261792792 |x 2380-6591 |7 nnns |
773 | 1 | 8 | |g volume:6 |g year:2021 |g number:1 |g day:01 |g month:01 |g pages:50-57 |
856 | 4 | 0 | |u http://dx.doi.org/10.1001/jamacardio.2020.4738 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 6 |j 2021 |e 1 |b 01 |c 01 |h 50-57 |