A simple paper-based approach for arsenic determination in water using hydride generation coupled with mercaptosuccinic-acid capped CdTe quantum dots
This research aims to develop a simple paper-based device for arsenic detection in water samples where a hydride generation technique coupled with mercaptosuccinic acid-capped CdTe quantum dots (MSA-CdTe QDs) as a detection probe was applied to the detection system. MSA-CdTe QDs were coated on a paper strip, inserted into the cover cap of a reaction bottle, to react with the developed arsine gas. Fluorescent emission of the QDs was quenched upon the presence of arsenic in solutions, whereby only a small amount of the MSA-CdTe QDs was required. The excitation and emission wavelengths for fluorescent detection were 278.5 nm and 548.5 nm, respectively. The proposed system provided a limit of detection of 0.016 mg L-1 and a limit of quantitation of 0.053 mg L-1, and a detection range of 0.05-30.00 mg L-1. In addition, the tolerance level of the detection approach to interference by other vapor-generated species was successfully improved by placing another paper strip coated with a solution of saturated lead acetate in front of the detection paper strip. This developed approach offered a simple and fast, yet accurate and selective detection of arsenic contaminated in water samples. In addition, the mechanism of fluorescent quenching was also proposed.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:12 |
---|---|
Enthalten in: |
Analytical methods : advancing methods and applications - 12(2020), 21 vom: 04. Juni, Seite 2718-2726 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Thepmanee, Oraphan [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 05.04.2021 Date Revised 05.04.2021 published: Print Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1039/d0ay00273a |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM315023031 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM315023031 | ||
003 | DE-627 | ||
005 | 20231225154018.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1039/d0ay00273a |2 doi | |
028 | 5 | 2 | |a pubmed24n1050.xml |
035 | |a (DE-627)NLM315023031 | ||
035 | |a (NLM)32930303 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Thepmanee, Oraphan |e verfasserin |4 aut | |
245 | 1 | 2 | |a A simple paper-based approach for arsenic determination in water using hydride generation coupled with mercaptosuccinic-acid capped CdTe quantum dots |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 05.04.2021 | ||
500 | |a Date Revised 05.04.2021 | ||
500 | |a published: Print | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a This research aims to develop a simple paper-based device for arsenic detection in water samples where a hydride generation technique coupled with mercaptosuccinic acid-capped CdTe quantum dots (MSA-CdTe QDs) as a detection probe was applied to the detection system. MSA-CdTe QDs were coated on a paper strip, inserted into the cover cap of a reaction bottle, to react with the developed arsine gas. Fluorescent emission of the QDs was quenched upon the presence of arsenic in solutions, whereby only a small amount of the MSA-CdTe QDs was required. The excitation and emission wavelengths for fluorescent detection were 278.5 nm and 548.5 nm, respectively. The proposed system provided a limit of detection of 0.016 mg L-1 and a limit of quantitation of 0.053 mg L-1, and a detection range of 0.05-30.00 mg L-1. In addition, the tolerance level of the detection approach to interference by other vapor-generated species was successfully improved by placing another paper strip coated with a solution of saturated lead acetate in front of the detection paper strip. This developed approach offered a simple and fast, yet accurate and selective detection of arsenic contaminated in water samples. In addition, the mechanism of fluorescent quenching was also proposed | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
700 | 1 | |a Prapainop, Kanlaya |e verfasserin |4 aut | |
700 | 1 | |a Noppha, Obnithi |e verfasserin |4 aut | |
700 | 1 | |a Rattanawimanwong, Nuanlaor |e verfasserin |4 aut | |
700 | 1 | |a Siangproh, Weena |e verfasserin |4 aut | |
700 | 1 | |a Chailapakul, Orawon |e verfasserin |4 aut | |
700 | 1 | |a Songsrirote, Kriangsak |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Analytical methods : advancing methods and applications |d 2009 |g 12(2020), 21 vom: 04. Juni, Seite 2718-2726 |w (DE-627)NLM202500322 |x 1759-9679 |7 nnns |
773 | 1 | 8 | |g volume:12 |g year:2020 |g number:21 |g day:04 |g month:06 |g pages:2718-2726 |
856 | 4 | 0 | |u http://dx.doi.org/10.1039/d0ay00273a |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 12 |j 2020 |e 21 |b 04 |c 06 |h 2718-2726 |