Development of an automated and High throughput UHPLC/MS based workflow for cleaning verification of potent compounds in the pharmaceutical manufacturing environment
Copyright © 2020 Elsevier B.V. All rights reserved..
Cleaning verification (CV) is a critical step in the pharmaceutical manufacturing process to eliminate or reduce unacceptable contamination of a product as a result of insufficiently cleaned equipment surfaces. The main concern is cross contamination with active pharmaceutical ingredients (APIs) from previous runs that may impact patient safety. Current conventional approaches involve rather tedious sample preparation and analytical methods with relative lengthy analysis time. Potent APIs possessing low acceptable daily intake (ADI) values require analytical methods for CV with very low detection limits to confirm that these APIs are below their acceptance limits prior to the next manufacturing process. In this work, a novel end to end CV workflow was developed, which includes the automated sample and calibration solution preparation as well as high throughput analysis by ultra-high-performance liquid chromatography (UHPLC) coupled with single quadrupole mass spectrometry in multiple injection chromatography and selected ion monitoring mode (MIC-MS-SIM). The method was validated using ten model compounds. Acceptable specificity, linearity (R2 > 0.997) and single digit ng/mL LOQ and LOD were achieved for all model compounds. This approach was also successfully applied to the analysis of 22 internal CV samples from an internal program.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:188 |
---|---|
Enthalten in: |
Journal of pharmaceutical and biomedical analysis - 188(2020) vom: 05. Sept., Seite 113401 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Sheng, Huaming [VerfasserIn] |
---|
Links: |
---|
Themen: |
Automation |
---|
Anmerkungen: |
Date Completed 17.06.2021 Date Revised 17.06.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.jpba.2020.113401 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM311416934 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM311416934 | ||
003 | DE-627 | ||
005 | 20231225142218.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jpba.2020.113401 |2 doi | |
028 | 5 | 2 | |a pubmed24n1038.xml |
035 | |a (DE-627)NLM311416934 | ||
035 | |a (NLM)32563056 | ||
035 | |a (PII)S0731-7085(20)31287-5 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Sheng, Huaming |e verfasserin |4 aut | |
245 | 1 | 0 | |a Development of an automated and High throughput UHPLC/MS based workflow for cleaning verification of potent compounds in the pharmaceutical manufacturing environment |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 17.06.2021 | ||
500 | |a Date Revised 17.06.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2020 Elsevier B.V. All rights reserved. | ||
520 | |a Cleaning verification (CV) is a critical step in the pharmaceutical manufacturing process to eliminate or reduce unacceptable contamination of a product as a result of insufficiently cleaned equipment surfaces. The main concern is cross contamination with active pharmaceutical ingredients (APIs) from previous runs that may impact patient safety. Current conventional approaches involve rather tedious sample preparation and analytical methods with relative lengthy analysis time. Potent APIs possessing low acceptable daily intake (ADI) values require analytical methods for CV with very low detection limits to confirm that these APIs are below their acceptance limits prior to the next manufacturing process. In this work, a novel end to end CV workflow was developed, which includes the automated sample and calibration solution preparation as well as high throughput analysis by ultra-high-performance liquid chromatography (UHPLC) coupled with single quadrupole mass spectrometry in multiple injection chromatography and selected ion monitoring mode (MIC-MS-SIM). The method was validated using ten model compounds. Acceptable specificity, linearity (R2 > 0.997) and single digit ng/mL LOQ and LOD were achieved for all model compounds. This approach was also successfully applied to the analysis of 22 internal CV samples from an internal program | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Automation | |
650 | 4 | |a Cleaning verification | |
650 | 4 | |a High throughput | |
650 | 4 | |a LC-MS | |
650 | 4 | |a Pharmaceutical manufacturing | |
650 | 7 | |a Pharmaceutical Preparations |2 NLM | |
700 | 1 | |a Kim, Dae |e verfasserin |4 aut | |
700 | 1 | |a Chin, Alexander S |e verfasserin |4 aut | |
700 | 1 | |a Zhao, Yuejie |e verfasserin |4 aut | |
700 | 1 | |a Liu, Yong |e verfasserin |4 aut | |
700 | 1 | |a Katwaru, Ravi |e verfasserin |4 aut | |
700 | 1 | |a Bateman, Kevin P |e verfasserin |4 aut | |
700 | 1 | |a Abend, Andreas |e verfasserin |4 aut | |
700 | 1 | |a Wuelfing, W Peter |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of pharmaceutical and biomedical analysis |d 1983 |g 188(2020) vom: 05. Sept., Seite 113401 |w (DE-627)NLM012641928 |x 1873-264X |7 nnns |
773 | 1 | 8 | |g volume:188 |g year:2020 |g day:05 |g month:09 |g pages:113401 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jpba.2020.113401 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 188 |j 2020 |b 05 |c 09 |h 113401 |