Glymphatic clearance of simulated silicon dispersion in mouse brain analyzed by laser induced breakdown spectroscopy
© 2020 The Authors..
Silicon-based devices, such as neural probes, are increasingly used as electrodes for receiving electrical signals from neural tissue. Neural probes used chronically have been known to induce inflammation and elicit an immune response. The current study detects and evaluates silicon dispersion from a concentrated source in the mouse brain using laser induced breakdown spectroscopy. Element lines for Si (I) were found at the injection site at approximately 288 nm at 3hr post-implantation, even with tissue perfusion, indicating possible infusion into neural tissue. At 24hr and 1-week post-implantation, no silicon lines were found, indicating clearance. An isolated immune response was found by CD68 macrophage response at 24hr post injection. Future studies should measure chronic silicon exposure to determine if the inflammatory response is proportional to silicon administration. The present type of protocol, coupling laser induced breakdown spectroscopy, neuroimaging, histology, immunohistochemistry, and determination of clearance could be used to investigate the glymphatic system and different tissue states such as in disease (e.g. Alzheimer's).
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:6 |
---|---|
Enthalten in: |
Heliyon - 6(2020), 4 vom: 01. Apr., Seite e03702 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Khan, Muhammad Shehzad [VerfasserIn] |
---|
Links: |
---|
Themen: |
Biophysics |
---|
Anmerkungen: |
Date Revised 28.09.2020 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.heliyon.2020.e03702 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM309070996 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM309070996 | ||
003 | DE-627 | ||
005 | 20231225133115.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.heliyon.2020.e03702 |2 doi | |
028 | 5 | 2 | |a pubmed24n1030.xml |
035 | |a (DE-627)NLM309070996 | ||
035 | |a (NLM)32322711 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Khan, Muhammad Shehzad |e verfasserin |4 aut | |
245 | 1 | 0 | |a Glymphatic clearance of simulated silicon dispersion in mouse brain analyzed by laser induced breakdown spectroscopy |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 28.09.2020 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2020 The Authors. | ||
520 | |a Silicon-based devices, such as neural probes, are increasingly used as electrodes for receiving electrical signals from neural tissue. Neural probes used chronically have been known to induce inflammation and elicit an immune response. The current study detects and evaluates silicon dispersion from a concentrated source in the mouse brain using laser induced breakdown spectroscopy. Element lines for Si (I) were found at the injection site at approximately 288 nm at 3hr post-implantation, even with tissue perfusion, indicating possible infusion into neural tissue. At 24hr and 1-week post-implantation, no silicon lines were found, indicating clearance. An isolated immune response was found by CD68 macrophage response at 24hr post injection. Future studies should measure chronic silicon exposure to determine if the inflammatory response is proportional to silicon administration. The present type of protocol, coupling laser induced breakdown spectroscopy, neuroimaging, histology, immunohistochemistry, and determination of clearance could be used to investigate the glymphatic system and different tissue states such as in disease (e.g. Alzheimer's) | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Biophysics | |
650 | 4 | |a Electrode | |
650 | 4 | |a Immune response | |
650 | 4 | |a Inflammation | |
650 | 4 | |a Neuroscience | |
650 | 4 | |a Optics | |
650 | 4 | |a Physics | |
650 | 4 | |a Physics methods | |
650 | 4 | |a Probe | |
650 | 4 | |a Silicon | |
650 | 4 | |a Toxicology | |
700 | 1 | |a Kumar, Rachit |e verfasserin |4 aut | |
700 | 1 | |a Manno, Sinai H C |e verfasserin |4 aut | |
700 | 1 | |a Ahmed, Irfan |e verfasserin |4 aut | |
700 | 1 | |a Lun Law, Alan Wing |e verfasserin |4 aut | |
700 | 1 | |a Cruces, Raul R |e verfasserin |4 aut | |
700 | 1 | |a Ma, Victor |e verfasserin |4 aut | |
700 | 1 | |a Cho, William C |e verfasserin |4 aut | |
700 | 1 | |a Cheng, Shuk Han |e verfasserin |4 aut | |
700 | 1 | |a Lau, Condon |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Heliyon |d 2015 |g 6(2020), 4 vom: 01. Apr., Seite e03702 |w (DE-627)NLM255913095 |x 2405-8440 |7 nnns |
773 | 1 | 8 | |g volume:6 |g year:2020 |g number:4 |g day:01 |g month:04 |g pages:e03702 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.heliyon.2020.e03702 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 6 |j 2020 |e 4 |b 01 |c 04 |h e03702 |