Portable pulsed xenon ultraviolet light disinfection in a teaching hospital animal laboratory in China
Copyright © 2020 Elsevier B.V. All rights reserved..
An animal laboratory in a teaching hospital is a possible cause of cross infection. We aimed to assess the infection control in our animal laboratory and evaluate the disinfectant effects of a portable pulsed xenon ultraviolet (PX-UV) machine. Samples were taken from the surface of research tables, other high touch places, such as doorknobs, weighing scales, and handles of trolleys, and from air in the barrier system pre- and post-manual cleaning and post-PX-UV disinfection. The bacteria types were identified. We found that routine manual cleaning significantly reduced bacterial colony form unit (CFU)/cm2 (P = .02), and the median of CFU/cm2 reduced from 0.5 pre-cleaning to zero post-cleaning. PX-UV disinfection also significantly reduced residual bacterial counts (P = .002), with the highest counts 10 pre-PX-UV disinfection and 1 afterwards. Without manual cleaning, PX-UV disinfected surfaces significantly (P < .001), median count 6 pre-PX-UV disinfection and zero afterwards. PX-UV significantly reduced bacterial colony counts in the air with the median count falling from 6 to zero (P < .001). Some of the 21 species of pathogens we identified in the current study are pathogenic, resistant to antibiotics, and able to cause nosocomial infections and zoonosis. PX-UV reduced counts of most of the pathogens. PX-UV is an effective agent against these pathogens.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:207 |
---|---|
Enthalten in: |
Journal of photochemistry and photobiology. B, Biology - 207(2020) vom: 08. Juni, Seite 111869 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Li, Jing-Jing [VerfasserIn] |
---|
Links: |
---|
Themen: |
3H3U766W84 |
---|
Anmerkungen: |
Date Completed 12.01.2021 Date Revised 01.02.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.jphotobiol.2020.111869 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM308633660 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM308633660 | ||
003 | DE-627 | ||
005 | 20231225132139.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jphotobiol.2020.111869 |2 doi | |
028 | 5 | 2 | |a pubmed24n1028.xml |
035 | |a (DE-627)NLM308633660 | ||
035 | |a (NLM)32278270 | ||
035 | |a (PII)S1011-1344(20)30316-X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Li, Jing-Jing |e verfasserin |4 aut | |
245 | 1 | 0 | |a Portable pulsed xenon ultraviolet light disinfection in a teaching hospital animal laboratory in China |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 12.01.2021 | ||
500 | |a Date Revised 01.02.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2020 Elsevier B.V. All rights reserved. | ||
520 | |a An animal laboratory in a teaching hospital is a possible cause of cross infection. We aimed to assess the infection control in our animal laboratory and evaluate the disinfectant effects of a portable pulsed xenon ultraviolet (PX-UV) machine. Samples were taken from the surface of research tables, other high touch places, such as doorknobs, weighing scales, and handles of trolleys, and from air in the barrier system pre- and post-manual cleaning and post-PX-UV disinfection. The bacteria types were identified. We found that routine manual cleaning significantly reduced bacterial colony form unit (CFU)/cm2 (P = .02), and the median of CFU/cm2 reduced from 0.5 pre-cleaning to zero post-cleaning. PX-UV disinfection also significantly reduced residual bacterial counts (P = .002), with the highest counts 10 pre-PX-UV disinfection and 1 afterwards. Without manual cleaning, PX-UV disinfected surfaces significantly (P < .001), median count 6 pre-PX-UV disinfection and zero afterwards. PX-UV significantly reduced bacterial colony counts in the air with the median count falling from 6 to zero (P < .001). Some of the 21 species of pathogens we identified in the current study are pathogenic, resistant to antibiotics, and able to cause nosocomial infections and zoonosis. PX-UV reduced counts of most of the pathogens. PX-UV is an effective agent against these pathogens | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Animal laboratory | |
650 | 4 | |a Disinfection | |
650 | 4 | |a Pulsed xenon ultraviolet light | |
650 | 7 | |a Xenon |2 NLM | |
650 | 7 | |a 3H3U766W84 |2 NLM | |
700 | 1 | |a Wang, Shan-Ni |e verfasserin |4 aut | |
700 | 1 | |a Qiao, Jiao-Jiao |e verfasserin |4 aut | |
700 | 1 | |a Chen, Li-Hua |e verfasserin |4 aut | |
700 | 1 | |a Li, Yu |e verfasserin |4 aut | |
700 | 1 | |a Wu, Yong |e verfasserin |4 aut | |
700 | 1 | |a Ding, Yan-Xia |e verfasserin |4 aut | |
700 | 1 | |a Wang, Mei-Mei |e verfasserin |4 aut | |
700 | 1 | |a Tian, Yun |e verfasserin |4 aut | |
700 | 1 | |a Liu, Yun-Bo |e verfasserin |4 aut | |
700 | 1 | |a Yan, Chen |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Chen |e verfasserin |4 aut | |
700 | 1 | |a Gao, Chang-Qing |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of photochemistry and photobiology. B, Biology |d 1990 |g 207(2020) vom: 08. Juni, Seite 111869 |w (DE-627)NLM013030868 |x 1873-2682 |7 nnns |
773 | 1 | 8 | |g volume:207 |g year:2020 |g day:08 |g month:06 |g pages:111869 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jphotobiol.2020.111869 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 207 |j 2020 |b 08 |c 06 |h 111869 |