3 Tesla MRI brain scanning under general anaesthesia in a paediatric 3 Tesla-compatible cochlear implant recipient, first reported case : Clinical considerations and implications for future practice
Copyright © 2020 Elsevier B.V. All rights reserved..
OBJECTIVES: To demonstrate the safety and feasibility of the first reported case of a 3 Tesla MRI scan in a paediatric 3 Tesla-compatible cochlear implant recipient under general anaesthesia.
MATERIALS AND METHODS: A three-year-old child with bilateral optic pathway glioma treated with chemotherapy, who subsequently received a right sided 3 Tesla-compatible cochlear implant for sensorineural hearing loss was examined. The CI device chosen was implanted due to its purported MRI compatibility. Following informed consent and hospital executive approval, the child underwent a 3 Tesla MRI scan to assess for growth of the optic pathway glioma.
RESULTS: A 3 Tesla MRI scan of the brain was performed under general anaesthesia. There was expected artefact due to the magnet of the receiver stimulator. There was no malfunction of the implant noted after the procedure, and no neurological or otological complications. The child had five more uneventful 3 Tesla MRI scans of the brain without complications.
CONCLUSION: This is the first reported case of a child with a 3 Tesla-compatible cochlear implant undergoing a 3 Tesla MRI scan of the brain under general anaesthesia. Provided manufacturer guidelines are adhered to, 3 Tesla MRI scanning should not be contraindicated in paediatric cochlear implant recipients with a compatible device.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:133 |
---|---|
Enthalten in: |
International journal of pediatric otorhinolaryngology - 133(2020) vom: 01. Juni, Seite 110015 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Zhen, Emily [VerfasserIn] |
---|
Links: |
---|
Themen: |
3 Tesla MRI |
---|
Anmerkungen: |
Date Completed 20.10.2020 Date Revised 20.10.2020 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.ijporl.2020.110015 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM308150082 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM308150082 | ||
003 | DE-627 | ||
005 | 20231225131126.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.ijporl.2020.110015 |2 doi | |
028 | 5 | 2 | |a pubmed24n1027.xml |
035 | |a (DE-627)NLM308150082 | ||
035 | |a (NLM)32229365 | ||
035 | |a (PII)S0165-5876(20)30158-0 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Zhen, Emily |e verfasserin |4 aut | |
245 | 1 | 0 | |a 3 Tesla MRI brain scanning under general anaesthesia in a paediatric 3 Tesla-compatible cochlear implant recipient, first reported case |b Clinical considerations and implications for future practice |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 20.10.2020 | ||
500 | |a Date Revised 20.10.2020 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2020 Elsevier B.V. All rights reserved. | ||
520 | |a OBJECTIVES: To demonstrate the safety and feasibility of the first reported case of a 3 Tesla MRI scan in a paediatric 3 Tesla-compatible cochlear implant recipient under general anaesthesia | ||
520 | |a MATERIALS AND METHODS: A three-year-old child with bilateral optic pathway glioma treated with chemotherapy, who subsequently received a right sided 3 Tesla-compatible cochlear implant for sensorineural hearing loss was examined. The CI device chosen was implanted due to its purported MRI compatibility. Following informed consent and hospital executive approval, the child underwent a 3 Tesla MRI scan to assess for growth of the optic pathway glioma | ||
520 | |a RESULTS: A 3 Tesla MRI scan of the brain was performed under general anaesthesia. There was expected artefact due to the magnet of the receiver stimulator. There was no malfunction of the implant noted after the procedure, and no neurological or otological complications. The child had five more uneventful 3 Tesla MRI scans of the brain without complications | ||
520 | |a CONCLUSION: This is the first reported case of a child with a 3 Tesla-compatible cochlear implant undergoing a 3 Tesla MRI scan of the brain under general anaesthesia. Provided manufacturer guidelines are adhered to, 3 Tesla MRI scanning should not be contraindicated in paediatric cochlear implant recipients with a compatible device | ||
650 | 4 | |a Case Reports | |
650 | 4 | |a Journal Article | |
650 | 4 | |a 3 Tesla MRI | |
650 | 4 | |a Cochlear implant | |
650 | 4 | |a MED-EL SYNCHRONY | |
650 | 4 | |a Paediatric | |
700 | 1 | |a Kuthubutheen, Jafri |e verfasserin |4 aut | |
700 | 1 | |a Misso, Dylan |e verfasserin |4 aut | |
700 | 1 | |a Rodrigues, Stephen |e verfasserin |4 aut | |
700 | 1 | |a Thompson, Andrew |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t International journal of pediatric otorhinolaryngology |d 1993 |g 133(2020) vom: 01. Juni, Seite 110015 |w (DE-627)NLM001226304 |x 1872-8464 |7 nnns |
773 | 1 | 8 | |g volume:133 |g year:2020 |g day:01 |g month:06 |g pages:110015 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ijporl.2020.110015 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 133 |j 2020 |b 01 |c 06 |h 110015 |