Magnetic susceptibility measurement by NMR : 1. The temperature dependence of TMS
Copyright © 2020 Elsevier Inc. All rights reserved..
Usually a dedicated susceptometer is needed to measure diamagnetism accurately. An NMR spectrometer is more readily available in most chemistry departments but till now has been inaccurate for measuring diamagnetism. An improved NMR method is introduced to measure the magnetic susceptibility, or diamagnetism with similar absolute accuracy as other methods. This is achieved by accurate modelling of the NMR sample shape and response profile of the probe. The new method is validated by comparing the measured diamagnetism of water against the literature standard to within 0.05%. As a first example of its application, the diamagnetism of CDCl3 was measured over a range of temperatures and used to reanalyze earlier measurements of the variation of the chemical shift of tetramethylsilane in CDCl3 against 3He gas. This improved on the accuracy and reliability of the result and will allow, for the first time, accurate studies of the absolute effect of temperature on chemical shift.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:312 |
---|---|
Enthalten in: |
Journal of magnetic resonance (San Diego, Calif. : 1997) - 312(2020) vom: 30. März, Seite 106689 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hoffman, Roy E [VerfasserIn] |
---|
Links: |
---|
Themen: |
Chemical shift standard |
---|
Anmerkungen: |
Date Revised 11.03.2020 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.jmr.2020.106689 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM306567105 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM306567105 | ||
003 | DE-627 | ||
005 | 20231225123641.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jmr.2020.106689 |2 doi | |
028 | 5 | 2 | |a pubmed24n1021.xml |
035 | |a (DE-627)NLM306567105 | ||
035 | |a (NLM)32062586 | ||
035 | |a (PII)S1090-7807(20)30007-0 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hoffman, Roy E |e verfasserin |4 aut | |
245 | 1 | 0 | |a Magnetic susceptibility measurement by NMR |b 1. The temperature dependence of TMS |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 11.03.2020 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Copyright © 2020 Elsevier Inc. All rights reserved. | ||
520 | |a Usually a dedicated susceptometer is needed to measure diamagnetism accurately. An NMR spectrometer is more readily available in most chemistry departments but till now has been inaccurate for measuring diamagnetism. An improved NMR method is introduced to measure the magnetic susceptibility, or diamagnetism with similar absolute accuracy as other methods. This is achieved by accurate modelling of the NMR sample shape and response profile of the probe. The new method is validated by comparing the measured diamagnetism of water against the literature standard to within 0.05%. As a first example of its application, the diamagnetism of CDCl3 was measured over a range of temperatures and used to reanalyze earlier measurements of the variation of the chemical shift of tetramethylsilane in CDCl3 against 3He gas. This improved on the accuracy and reliability of the result and will allow, for the first time, accurate studies of the absolute effect of temperature on chemical shift | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Chemical shift standard | |
650 | 4 | |a Diamagnetism | |
650 | 4 | |a Magnetic susceptibility | |
773 | 0 | 8 | |i Enthalten in |t Journal of magnetic resonance (San Diego, Calif. : 1997) |d 1998 |g 312(2020) vom: 30. März, Seite 106689 |w (DE-627)NLM091000068 |x 1096-0856 |7 nnns |
773 | 1 | 8 | |g volume:312 |g year:2020 |g day:30 |g month:03 |g pages:106689 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jmr.2020.106689 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 312 |j 2020 |b 30 |c 03 |h 106689 |