Emergency percutaneous thoracic endovascular aortic repair for patients with traumatic thoracic aortic blunt injury : A single center experience

Copyright © 2020. Production and hosting by Elsevier B.V..

PURPOSE: To analyze the efficacy and outcome of percutaneous thoracic endovascular aortic repair (TEVAR) in patients with traumatic blunt aortic injury in our single-center.

METHODS: From January 2014 to December 2018, a total of 89 patients with traumatic blunt aortic injuries were treated with emergency TEVAR in our center. Their clinical data such as demographics, operative details and postprocedure outcomes were analyzed retrospectively in this study using SPSS 20 software. Continuous variables were expressed as mean and standard deviation or median and interquartile range. Categorical variables are expressed as the numbers and percentages of patients.

RESULTS: The median age of the patients was 37 years, and 76 (85.4%) were males. All the patients were involved in violent accidents and combined with associated injuries. Two patients died while awaiting the operations and 87 patients underwent emergency percutaneous TEVAR, with a 100% technique success. The mean time interval from admission to operating room was (90.1 ± 18.7) min, and the mean procedure time was (54.6 ± 11.9) min. Eighty (92.0%) patients were operated on under local anesthesia, while other 7 (8.0%) patients were under general anesthesia. Two cases underwent open repair of the femoral arteries because of the pseudoaneurysm formation of the access vessels. A total of 98 aortic covered stent grafts were deployed, of which 11 patients used two stent grafts (all in dissection cases). The length of the stent was (177.5 ± 24.6) mm. The horizontal diameter of aorta arch at the proximal left subclavian artery ostium was (24.9 ± 2.4) mm, the proximal diameter of the covered stent was (30.5 ± 2.6) mm, and the oversize rate of proximal site was (22.7 ± 4.0)%. The proximal landing zone length was (14.1 ± 5.5) mm. The left subclavian artery ostium was completely covered in 5 patients and partially covered in 32 patients. No blood flow reconstruction was performed. The overall aortic-related mortality was 2.25% (2/89). Among 87 patients, the median follow-up time was 24 months. Postoperative computed tomography angiography scans demonstrated no residual pseudoaneurysm, hematoma or endoleak. One patient complained of mild left upper limb weakness during follow-up due to left subclavian artery occlusion. Neither late death, nor neurological or other complications occurred.

CONCLUSION: Emergency percutaneous endovascular repair is a less invasive and effective approach for the treatment of traumatic blunt aortic injuries. Long-term results remain to be further followed.

Medienart:

E-Artikel

Erscheinungsjahr:

2020

Erschienen:

2020

Enthalten in:

Zur Gesamtaufnahme - volume:23

Enthalten in:

Chinese journal of traumatology = Zhonghua chuang shang za zhi - 23(2020), 1 vom: 01. Feb., Seite 15-19

Sprache:

Englisch

Beteiligte Personen:

Pu, Xin [VerfasserIn]
Huang, Xiao-Yong [VerfasserIn]
Huang, Lian-Jun [VerfasserIn]

Links:

Volltext

Themen:

Blunt aortic injury
Endovascular aortic repair
Journal Article
Nonpenetrating wounds

Anmerkungen:

Date Completed 31.08.2020

Date Revised 10.01.2021

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1016/j.cjtee.2019.11.006

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM306517396