Quantification of Esophageal Tumor Motion and Investigation of Different Image-Guided Correction Strategies

Copyright © 2019 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved..

PURPOSE: To accurately quantify esophageal tumor position variability and to optimize image guided correction strategies.

MATERIAL AND METHODS: Esophageal cancer patients receiving chemoradiotherapy (41.4-50.4 Gy in 23-28 fractions combined with carboplatin plus paclitaxel) were included in a prospective cohort study (NCT02139488). Gold fiducial markers were inserted into the esophageal tumors during diagnostic endoscopic ultrasound. Four-dimensional (4D) planning computed tomography (CT) and daily 4D cone beam (CB) CT scans were acquired. Each CBCT was registered to the planning CT using different regions of interest (bone; 3D), and carina, diaphragm, clinical target volume (CTV), and fiducial markers (4D) for alignment and using the fiducial markers as the true tumor position. Subsequently, a planning target volume (PTV) margin accounting for residual uncertainties, including the average respiratory motion, was calculated for each of these registrations.

RESULTS: Fifty-six patients with tumors located in the proximal (n = 1), mid (n = 7), or distal esophagus (n = 25) or at the gastroesophageal junction (n = 23) were included. The average peak-to-peak respiratory tumor motion was 0.20, 0.92, and 0.34 cm on the planning CT in left-right (LR), cranial-caudal (CC), and anterior-posterior (AP) directions, respectively. The required PTV margin with average motion amplitude, depending on the correction strategy used for image guidance, ranged from 0.8 cm to 1.0 cm, 1.1 cm to 1.6 cm, and 0.7 cm to 0.9 cm in LR, CC, and AP direction, respectively. A registration based on the CTV resulted in the smallest PTV margins (0.8, 1.1, and 0.7 cm in LR, CC, and AP direction, respectively). For bone registration the calculated PTV margins were 1.0, 1.3, and 0.7 cm in LR, CC, and AP directions, respectively. The registration based on the diaphragm increased PTV margins.

CONCLUSIONS: Substantial and anisotropic position variability of esophageal tumors was observed during radiation therapy, and nonuniform margins should be considered. Cranial-caudal PTV margins need to be larger than those commonly used. Target positioning during image-guided radiotherapy could be improved with a CTV registration-based correction strategy.

Medienart:

E-Artikel

Erscheinungsjahr:

2020

Erschienen:

2020

Enthalten in:

Zur Gesamtaufnahme - volume:10

Enthalten in:

Practical radiation oncology - 10(2020), 2 vom: 01. März, Seite 84-92

Sprache:

Englisch

Beteiligte Personen:

Voncken, Francine E M [VerfasserIn]
Nakhaee, Sareh [VerfasserIn]
Stam, Barbara [VerfasserIn]
Wiersema, Lisa [VerfasserIn]
Vollenbrock, Sophie E [VerfasserIn]
van Dieren, Jolanda M [VerfasserIn]
van Leerdam, Monique E [VerfasserIn]
Sonke, Jan-Jakob [VerfasserIn]
Aleman, Berthe M P [VerfasserIn]
Remeijer, Peter [VerfasserIn]

Links:

Volltext

Themen:

Journal Article

Anmerkungen:

Date Completed 15.10.2020

Date Revised 15.10.2020

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1016/j.prro.2019.11.012

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM303883758