Development and validation of an ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine the bioavailability of warfarin and its major metabolite 7-hydroxy warfarin in rats dosed with oral formulations containing different polymorphic forms
© 2019 John Wiley & Sons, Ltd..
A simple, sensitive and rapid ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method was developed and validated for the quantification of warfarin and 7-hydroxy warfarin in Sprague Dawley (SD) rats. Animals were administered a single dose of warfarin sodium formulations (crystalline and amorphous) at 12 mg/kg via oral gavage and blood was drawn over a 96-h time course. Sample process recoveries, matrix effect and analyte stability were determined. The linearity for warfarin and 7-hydroxy warfarin was from 5 to 2000 ng/mL in blank SD rat plasma. Correlation coefficients (r2 ) for standard calibration curves were >.98 and analytes quantified within ±15% of target at all calibrator concentrations. The average percent accuracy and precision for intra- and inter-day were 93.7%-113.8% and ≤12.1%, respectively, for warfarin and 7-hydroxy warfarin, across the quality control standards (5, 10, 500, 1800 and 2000 ng/mL). Acceptable analytical recovery (>55%) was achieved with process efficiencies >41.5% and matrix effects <139.9% over the analytical range. Both analytes were stable in stock solution, autosampler, benchtop and three cycles of freeze-thaw with percent accuracy ≥90.2% and precision (percent relative standard deviation) ≤14%. The validated method was successfully applied to a pre-clinical bioavailability study of crystalline and amorphous warfarin sodium formulations in SD rats.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2019 |
---|---|
Erschienen: |
2019 |
Enthalten in: |
Zur Gesamtaufnahme - volume:33 |
---|---|
Enthalten in: |
Biomedical chromatography : BMC - 33(2019), 12 vom: 21. Dez., Seite e4685 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Shakleya, Diaa [VerfasserIn] |
---|
Links: |
---|
Themen: |
5Q7ZVV76EI |
---|
Anmerkungen: |
Date Completed 27.12.2019 Date Revised 08.01.2020 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1002/bmc.4685 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM300407513 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM300407513 | ||
003 | DE-627 | ||
005 | 20231225102447.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/bmc.4685 |2 doi | |
028 | 5 | 2 | |a pubmed24n1001.xml |
035 | |a (DE-627)NLM300407513 | ||
035 | |a (NLM)31430835 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Shakleya, Diaa |e verfasserin |4 aut | |
245 | 1 | 0 | |a Development and validation of an ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine the bioavailability of warfarin and its major metabolite 7-hydroxy warfarin in rats dosed with oral formulations containing different polymorphic forms |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 27.12.2019 | ||
500 | |a Date Revised 08.01.2020 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2019 John Wiley & Sons, Ltd. | ||
520 | |a A simple, sensitive and rapid ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method was developed and validated for the quantification of warfarin and 7-hydroxy warfarin in Sprague Dawley (SD) rats. Animals were administered a single dose of warfarin sodium formulations (crystalline and amorphous) at 12 mg/kg via oral gavage and blood was drawn over a 96-h time course. Sample process recoveries, matrix effect and analyte stability were determined. The linearity for warfarin and 7-hydroxy warfarin was from 5 to 2000 ng/mL in blank SD rat plasma. Correlation coefficients (r2 ) for standard calibration curves were >.98 and analytes quantified within ±15% of target at all calibrator concentrations. The average percent accuracy and precision for intra- and inter-day were 93.7%-113.8% and ≤12.1%, respectively, for warfarin and 7-hydroxy warfarin, across the quality control standards (5, 10, 500, 1800 and 2000 ng/mL). Acceptable analytical recovery (>55%) was achieved with process efficiencies >41.5% and matrix effects <139.9% over the analytical range. Both analytes were stable in stock solution, autosampler, benchtop and three cycles of freeze-thaw with percent accuracy ≥90.2% and precision (percent relative standard deviation) ≤14%. The validated method was successfully applied to a pre-clinical bioavailability study of crystalline and amorphous warfarin sodium formulations in SD rats | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a 7-hydroxy warfarin, amorphous, bioavailability, crystalline, LC-ESI-MS/MS, warfarin | |
650 | 7 | |a Warfarin |2 NLM | |
650 | 7 | |a 5Q7ZVV76EI |2 NLM | |
650 | 7 | |a 7-hydroxywarfarin |2 NLM | |
650 | 7 | |a B92SFW09LJ |2 NLM | |
700 | 1 | |a Rahman, Ziyaur |e verfasserin |4 aut | |
700 | 1 | |a Faustino, Patrick J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Biomedical chromatography : BMC |d 1987 |g 33(2019), 12 vom: 21. Dez., Seite e4685 |w (DE-627)NLM012669806 |x 1099-0801 |7 nnns |
773 | 1 | 8 | |g volume:33 |g year:2019 |g number:12 |g day:21 |g month:12 |g pages:e4685 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/bmc.4685 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 33 |j 2019 |e 12 |b 21 |c 12 |h e4685 |