Guaranteed [Formula : see text]-optimal solutions with the linear optimizer ART3+O
The linear optimization algorithm ART3+O introduced by Chen et al (2010 Med. Phys. 37 4938-45) can efficiently solve large scale inverse planning problems encountered in radiation therapy by iterative projection. Its major weakness is that it cannot guarantee [Formula: see text]-optimality of the final solution due to an arbitrary stopping criterion. We propose an improvement to ART3+O where the stopping criterion is based on Farkas' lemma. The same theory can be used to detect inconsistency in other projection methods as well. The proposed algorithm guarantees to find an [Formula: see text]-optimal solution in finite time. The algorithm is demonstrated on numerical examples in radiation therapy.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2019 |
---|---|
Erschienen: |
2019 |
Enthalten in: |
Zur Gesamtaufnahme - volume:64 |
---|---|
Enthalten in: |
Physics in medicine and biology - 64(2019), 7 vom: 04. Apr., Seite 075017 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Gorissen, Bram L [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 12.02.2020 Date Revised 12.02.2020 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.1088/1361-6560/ab0a2e |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM295674253 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM295674253 | ||
003 | DE-627 | ||
005 | 20231225084155.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1088/1361-6560/ab0a2e |2 doi | |
028 | 5 | 2 | |a pubmed24n0985.xml |
035 | |a (DE-627)NLM295674253 | ||
035 | |a (NLM)30945663 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Gorissen, Bram L |e verfasserin |4 aut | |
245 | 1 | 0 | |a Guaranteed [Formula |b see text]-optimal solutions with the linear optimizer ART3+O |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 12.02.2020 | ||
500 | |a Date Revised 12.02.2020 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The linear optimization algorithm ART3+O introduced by Chen et al (2010 Med. Phys. 37 4938-45) can efficiently solve large scale inverse planning problems encountered in radiation therapy by iterative projection. Its major weakness is that it cannot guarantee [Formula: see text]-optimality of the final solution due to an arbitrary stopping criterion. We propose an improvement to ART3+O where the stopping criterion is based on Farkas' lemma. The same theory can be used to detect inconsistency in other projection methods as well. The proposed algorithm guarantees to find an [Formula: see text]-optimal solution in finite time. The algorithm is demonstrated on numerical examples in radiation therapy | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
773 | 0 | 8 | |i Enthalten in |t Physics in medicine and biology |d 1956 |g 64(2019), 7 vom: 04. Apr., Seite 075017 |w (DE-627)NLM000336505 |x 1361-6560 |7 nnns |
773 | 1 | 8 | |g volume:64 |g year:2019 |g number:7 |g day:04 |g month:04 |g pages:075017 |
856 | 4 | 0 | |u http://dx.doi.org/10.1088/1361-6560/ab0a2e |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 64 |j 2019 |e 7 |b 04 |c 04 |h 075017 |