Quantitative and qualitative assessment of frontal plane knee motion in males and females : A reliability and validity study
Copyright © 2018 Elsevier B.V. All rights reserved..
BACKGROUND: The aim was to determine reliability and validity of frontal plane projection angle (FPPA) and visual assessments (VA) in both males and females.
METHODS: Fifty-four participants (30 females) performed lateral step-downs while kinematics were recorded by two-dimensional and three-dimensional analyses. Two raters viewed the videos, extracted images, and measured the FPPA (quantitative). Using the videos, the raters also categorized (qualitative VA) each participant's motion as demonstrating dynamic valgus (>10° valgus), dynamic varus (>10° varus), or no change. Reliability was assessed for FPPA and VA using intraclass correlation coefficients and Kappa, respectively. Validity was determined by comparing the FPPA to three-dimensional measures (Pearson correlations) and comparing the VA to both FPPA and standard reference 3D kinematics (Kappa).
RESULTS: FPPA showed good-excellent reliability (ICC = 0.850-0.998). VA showed minimal-moderate reliability (κ = 0.370-0.766). The FPPA showed large correlations (r = -0.514-0.531) with hip adduction in both sexes but only a moderate relationship with knee abduction in males (r = 0.427-0.445). VA showed no-weak (κ = 0.153-0.475) and weak-moderate (κ = 0.455-0.698) agreement compared to FPPA and no-weak (κ = -0.300-0.183) and no-minimal (κ = -0.078-0.027) disagreement compared to the reference standard 3D kinematics in males and females, respectively.
CONCLUSION: The quantitative FPPA is more reliable and valid than qualitative VA of frontal knee plane motion.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2018 |
---|---|
Erschienen: |
2018 |
Enthalten in: |
Zur Gesamtaufnahme - volume:25 |
---|---|
Enthalten in: |
The Knee - 25(2018), 6 vom: 29. Dez., Seite 1057-1064 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Simon, Madeline [VerfasserIn] |
---|
Links: |
---|
Themen: |
Agreement |
---|
Anmerkungen: |
Date Completed 11.03.2019 Date Revised 10.12.2019 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.knee.2018.09.008 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM290474507 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM290474507 | ||
003 | DE-627 | ||
005 | 20231225064819.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.knee.2018.09.008 |2 doi | |
028 | 5 | 2 | |a pubmed24n0968.xml |
035 | |a (DE-627)NLM290474507 | ||
035 | |a (NLM)30414788 | ||
035 | |a (PII)S0968-0160(18)30820-2 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Simon, Madeline |e verfasserin |4 aut | |
245 | 1 | 0 | |a Quantitative and qualitative assessment of frontal plane knee motion in males and females |b A reliability and validity study |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 11.03.2019 | ||
500 | |a Date Revised 10.12.2019 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2018 Elsevier B.V. All rights reserved. | ||
520 | |a BACKGROUND: The aim was to determine reliability and validity of frontal plane projection angle (FPPA) and visual assessments (VA) in both males and females | ||
520 | |a METHODS: Fifty-four participants (30 females) performed lateral step-downs while kinematics were recorded by two-dimensional and three-dimensional analyses. Two raters viewed the videos, extracted images, and measured the FPPA (quantitative). Using the videos, the raters also categorized (qualitative VA) each participant's motion as demonstrating dynamic valgus (>10° valgus), dynamic varus (>10° varus), or no change. Reliability was assessed for FPPA and VA using intraclass correlation coefficients and Kappa, respectively. Validity was determined by comparing the FPPA to three-dimensional measures (Pearson correlations) and comparing the VA to both FPPA and standard reference 3D kinematics (Kappa) | ||
520 | |a RESULTS: FPPA showed good-excellent reliability (ICC = 0.850-0.998). VA showed minimal-moderate reliability (κ = 0.370-0.766). The FPPA showed large correlations (r = -0.514-0.531) with hip adduction in both sexes but only a moderate relationship with knee abduction in males (r = 0.427-0.445). VA showed no-weak (κ = 0.153-0.475) and weak-moderate (κ = 0.455-0.698) agreement compared to FPPA and no-weak (κ = -0.300-0.183) and no-minimal (κ = -0.078-0.027) disagreement compared to the reference standard 3D kinematics in males and females, respectively | ||
520 | |a CONCLUSION: The quantitative FPPA is more reliable and valid than qualitative VA of frontal knee plane motion | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Validation Study | |
650 | 4 | |a Agreement | |
650 | 4 | |a Frontal plane projection angle | |
650 | 4 | |a Knee valgus | |
650 | 4 | |a Three-dimensional motion capture | |
650 | 4 | |a Two-dimensional video analysis | |
700 | 1 | |a Parizek, Chloe |e verfasserin |4 aut | |
700 | 1 | |a Earl-Boehm, Jennifer E |e verfasserin |4 aut | |
700 | 1 | |a Bazett-Jones, David M |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The Knee |d 1997 |g 25(2018), 6 vom: 29. Dez., Seite 1057-1064 |w (DE-627)NLM093742126 |x 1873-5800 |7 nnns |
773 | 1 | 8 | |g volume:25 |g year:2018 |g number:6 |g day:29 |g month:12 |g pages:1057-1064 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.knee.2018.09.008 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 25 |j 2018 |e 6 |b 29 |c 12 |h 1057-1064 |