Multiple-Sine-Slit Microdensitometer and MTF Evaluation for High Resolution Emulsions. 2 : MTF Data and Other Recording Parameters of High Resolution Emulsions for Holography
By means of the Multiple-Sine-Slit Microdensitometer (MSSM), MTF's up to 1500 c/mm have been evaluated for five photographic plates for holography, Agfa-Gevaert Scientia 10E75, 8E75, 8E75B, and Kodak 649-F and Type 120-02. For comparison, an as-if-MTF has also been derived from diffraction efficiency measurements. In addition sensitivity at lambda = 633 nm, the macroscopic characteristic tau(A) vs logE and alpha(2)(E), and scattered-flux data are reported for these five plates.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
1974 |
---|---|
Erschienen: |
1974 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Applied optics - 13(1974), 10 vom: 01. Okt., Seite 2288-91 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Johansson, S [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 02.10.2012 Date Revised 23.10.2018 published: Print Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1364/AO.13.002288 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM194900142 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM194900142 | ||
003 | DE-627 | ||
005 | 20231223201635.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231223s1974 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1364/AO.13.002288 |2 doi | |
028 | 5 | 2 | |a pubmed24n0650.xml |
035 | |a (DE-627)NLM194900142 | ||
035 | |a (NLM)20134677 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Johansson, S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Multiple-Sine-Slit Microdensitometer and MTF Evaluation for High Resolution Emulsions. 2 |b MTF Data and Other Recording Parameters of High Resolution Emulsions for Holography |
264 | 1 | |c 1974 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 02.10.2012 | ||
500 | |a Date Revised 23.10.2018 | ||
500 | |a published: Print | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a By means of the Multiple-Sine-Slit Microdensitometer (MSSM), MTF's up to 1500 c/mm have been evaluated for five photographic plates for holography, Agfa-Gevaert Scientia 10E75, 8E75, 8E75B, and Kodak 649-F and Type 120-02. For comparison, an as-if-MTF has also been derived from diffraction efficiency measurements. In addition sensitivity at lambda = 633 nm, the macroscopic characteristic tau(A) vs logE and alpha(2)(E), and scattered-flux data are reported for these five plates | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Biedermann, K |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Applied optics |d 1966 |g 13(1974), 10 vom: 01. Okt., Seite 2288-91 |w (DE-627)NLM114401330 |x 1539-4522 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:1974 |g number:10 |g day:01 |g month:10 |g pages:2288-91 |
856 | 4 | 0 | |u http://dx.doi.org/10.1364/AO.13.002288 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 1974 |e 10 |b 01 |c 10 |h 2288-91 |