Parallel imaging of knee cartilage at 3 Tesla
(c) 2007 Wiley-Liss, Inc..
PURPOSE: To evaluate the feasibility and reproducibility of quantitative cartilage imaging with parallel imaging at 3T and to determine the impact of the acceleration factor (AF) on morphological and relaxation measurements.
MATERIALS AND METHODS: An eight-channel phased-array knee coil was employed for conventional and parallel imaging on a 3T scanner. The imaging protocol consisted of a T2-weighted fast spin echo (FSE), a 3D-spoiled gradient echo (SPGR), a custom 3D-SPGR T1rho, and a 3D-SPGR T2 sequence. Parallel imaging was performed with an array spatial sensitivity technique (ASSET). The left knees of six healthy volunteers were scanned with both conventional and parallel imaging (AF = 2).
RESULTS: Morphological parameters and relaxation maps from parallel imaging methods (AF = 2) showed comparable results with conventional method. The intraclass correlation coefficient (ICC) of the two methods for cartilage volume, mean cartilage thickness, T1rho, and T2 were 0.999, 0.977, 0.964, and 0.969, respectively, while demonstrating excellent reproducibility. No significant measurement differences were found when AF reached 3 despite the low signal-to-noise ratio (SNR).
CONCLUSION: The study demonstrated that parallel imaging can be applied to current knee cartilage quantification at AF = 2 without degrading measurement accuracy with good reproducibility while effectively reducing scan time. Shorter imaging times can be achieved with higher AF at the cost of SNR.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2007 |
---|---|
Erschienen: |
2007 |
Enthalten in: |
Zur Gesamtaufnahme - volume:26 |
---|---|
Enthalten in: |
Journal of magnetic resonance imaging : JMRI - 26(2007), 4 vom: 05. Okt., Seite 1001-9 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Zuo, Jin [VerfasserIn] |
---|
Themen: |
Journal Article |
---|
Anmerkungen: |
Date Completed 03.01.2008 Date Revised 22.11.2016 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM174006446 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM174006446 | ||
003 | DE-627 | ||
005 | 20231223134958.0 | ||
007 | tu | ||
008 | 231223s2007 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a pubmed24n0580.xml |
035 | |a (DE-627)NLM174006446 | ||
035 | |a (NLM)17896394 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Zuo, Jin |e verfasserin |4 aut | |
245 | 1 | 0 | |a Parallel imaging of knee cartilage at 3 Tesla |
264 | 1 | |c 2007 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 03.01.2008 | ||
500 | |a Date Revised 22.11.2016 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a (c) 2007 Wiley-Liss, Inc. | ||
520 | |a PURPOSE: To evaluate the feasibility and reproducibility of quantitative cartilage imaging with parallel imaging at 3T and to determine the impact of the acceleration factor (AF) on morphological and relaxation measurements | ||
520 | |a MATERIALS AND METHODS: An eight-channel phased-array knee coil was employed for conventional and parallel imaging on a 3T scanner. The imaging protocol consisted of a T2-weighted fast spin echo (FSE), a 3D-spoiled gradient echo (SPGR), a custom 3D-SPGR T1rho, and a 3D-SPGR T2 sequence. Parallel imaging was performed with an array spatial sensitivity technique (ASSET). The left knees of six healthy volunteers were scanned with both conventional and parallel imaging (AF = 2) | ||
520 | |a RESULTS: Morphological parameters and relaxation maps from parallel imaging methods (AF = 2) showed comparable results with conventional method. The intraclass correlation coefficient (ICC) of the two methods for cartilage volume, mean cartilage thickness, T1rho, and T2 were 0.999, 0.977, 0.964, and 0.969, respectively, while demonstrating excellent reproducibility. No significant measurement differences were found when AF reached 3 despite the low signal-to-noise ratio (SNR) | ||
520 | |a CONCLUSION: The study demonstrated that parallel imaging can be applied to current knee cartilage quantification at AF = 2 without degrading measurement accuracy with good reproducibility while effectively reducing scan time. Shorter imaging times can be achieved with higher AF at the cost of SNR | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 7 | |a Spin Labels |2 NLM | |
700 | 1 | |a Li, Xiaojuan |e verfasserin |4 aut | |
700 | 1 | |a Banerjee, Suchandrima |e verfasserin |4 aut | |
700 | 1 | |a Han, Eric |e verfasserin |4 aut | |
700 | 1 | |a Majumdar, Sharmila |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of magnetic resonance imaging : JMRI |d 1996 |g 26(2007), 4 vom: 05. Okt., Seite 1001-9 |w (DE-627)NLM013085476 |x 1522-2586 |7 nnns |
773 | 1 | 8 | |g volume:26 |g year:2007 |g number:4 |g day:05 |g month:10 |g pages:1001-9 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 26 |j 2007 |e 4 |b 05 |c 10 |h 1001-9 |